background image

 

– 1 – 

AtlasSound.com

Specifications are subject to change without notice.

Owner’s Manual

AP-C15D Power Conditioner

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

AP-C15D Power Conditioner

Unswitched Outlets 120V 10A

Circuit

Breaker

Power

Power

On

Wiring

Fault

Breaker

Open

AC

Fault

Abnormal

Voltage

AC Mains Voltage

AP-C15D

Power Conditioner

Off

Low

High

15A

1601 JackMcKay Blvd • Ennis, TX 75119
www.atlassound.com

On

Off

Lamp

Filtered Outlets 120V, 60Hz, 10A MAX, 1200W

High Current

120V 10A, Unfiltered 

Unswitched

120V 10A

AC 120V 60Hz

1440W, 12A

Содержание AP-C15D

Страница 1: ...765 3435 AP C15D Power Conditioner Unswitched Outlets 120V 10A Circuit Breaker Power Power On Wiring Fault Breaker Open AC Fault Abnormal Voltage AC Mains Voltage AP C15D Power Conditioner Off Low High 15A 1601 JackMcKay Blvd Ennis TX 75119 www atlassound com On Off Lamp Filtered Outlets 120V 60Hz 10A MAX 1200W High Current 120V 10A Unfiltered Unswitched 120V 10A AC 120V 60Hz 1440W 12A ...

Страница 2: ...r Conditioner 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Table of Contents Safety Instructions 3 Introduction 5 Key Features 6 Applications 6 Front Panel Features 6 Rear Panel Features 8 Installation 8 Troubleshooting Guide 9 Specifications 10 Warranty 12 ...

Страница 3: ...e cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has ...

Страница 4: ... holes of the product s cover as this may result in electric shock or fire Do not place any containers with liquid or metallic objects on the top of the product If any liquid spills into the unit fire or electric shock may result Never operate this product or touch the power supply cord during an electrical storm electric shock may result Never exceed the wattage on the product when connecting equ...

Страница 5: ...l problem the AP C15D features Dual Clamping Suppression technology DCS If a spike intrudes the AC system the AP C15D incoming AC Mains has special suppression circuitry to eliminate the unwanted energy and in the unlike ly event of any energy getting pass the first stage each output section has redundant DCS circuitry clamping the unwanted energy This circuitry is very fast and can suppress unwan...

Страница 6: ...hose inconveniences The following are just a few examples of applications the AP C15D can be used Restaurants Houses of Worship Schools Home Theaters Office Buildings Sports Bars Front Panel Features 1 Unswitched AC Outlet The two 120VAC outlets are always live when the AP C15D power cord is plugged into an AC mains power source and voltage is present If voltage is present at the outlets it will b...

Страница 7: ...d into the AP C15D High AC Line Mains The Abnormal Voltage LED will flash between 128VAC 132VAC indicating possible damage may occur to equipment due to high AC Mains voltage The AP C15D outlets will remain active but the LED will stay flashing even if the voltage returns to a normal operating range To stop the LED from flashing the Power switch must be cycled Off Note It is recommend ed prior to ...

Страница 8: ...on the AC Mains Meter Note The AC mains power switch does not affect the Unswitched AC Outlets The Unswitched Outlets are protected by the surge protection circuitry but will not be shut off by the EVS circuit 5 XLR Light Socket A 12VDC XLR light socket provides power for the optional ECS GNL light 6 Light Socket Power Switch This switch turns the XLR light socket ON OFF Installation Before instal...

Страница 9: ...ent that was connected to that AC Mains Line to be inspected for proper operation If the problem persists contact your local power company for the cause of unstable AC line conditions Issue Abnormal LED Flashing and you have power to all outlets Possible Cause The AC Mains Voltage exceeded 128VAC or the voltage dropped below 107VAC Action Needed The AP C15D must be reset to turn off the LED Measur...

Страница 10: ...o position On Off AC Mains Power Cord 9 3m 14 gauge Technical Data Current Rating 15 amps Operating Voltage 102VAC 132VAC High Voltage Surge Protection Trigger at 133VAC 1ms typically Low Voltage Protection Trigger 101VAC 1ms typically Voltmeter Accuracy 1 5VAC Spike Protection Modes DCS Dual Clamping Suppression Circuitry on Incoming AC Mains and Each Section Output Min Spike Clamping Voltage 460...

Страница 11: ... 11 AtlasSound com Specifications are subject to change without notice Owner s Manual AP C15D Power Conditioner 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Notes ...

Страница 12: ...inal sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replace ment under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written re...