Multi-Impedance High Power Amplifier

Содержание HPA Series

Страница 1: ... 1 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A HPA2408 Multi Impedance High Power Amplifier ...

Страница 2: ... Instructions 3 Introduction 5 Key Features 5 Front Panel Description 6 Tamper Proof Security Cover 6 Rear Panel Description 8 Rear Panel Input and Output Switch Configurations 9 Remote Turn On 10 Placement of the Amp 12 Cabling 12 Selecting the AC Mains Source 12 Connecting the HPA Amplifier to AC Mains 13 Optional Dante Input Card 14 Specifications 15 Warranty 20 ...

Страница 3: ...ed liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 This product is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet c...

Страница 4: ...hen connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink or cut the power cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the product itself doing so may result in fire o...

Страница 5: ...evel controls with a security cover remote turn on balanced line inputs with sensitivity settings fault reporting and an accessory card slots for an optional Dante eight channel digital audio interface Cooling is not an issue because of the unique output stage low resistance direct couple thermal transfer design HPA also is energy efficient and meets most low energy savings requirements for amplif...

Страница 6: ... bi color LED giving status of the amplifier power supply Illuminated amber The HPA Amplifier is in Energy Save Mode and is not ready for use The rear panel remote activation control port has to be triggered by applying 5 24DC Voltage or shorting the Contact Closure CC and ground GND pins together to activate the amplifier to ready status Note The HPA Amp is shipped with a shunt across the CC and ...

Страница 7: ...owing four conditions No output will occur while this LED is illuminated This condition will be reset after the protect condition has been corrected 1 Shorted loudspeaker output 2 Power Supply If the amplifier exceeds its safe operating temperature both output channels will be muted with both Protect LEDs illuminated to show the amp is in Protect Mode The power supply will remain in protect Mode u...

Страница 8: ...ntact Closure in place or DC voltage 5 24VDC present The unit is always connected to the mains whether the switch is in the On or Off position 3 AC Mains Breaker If the current drawn from the amplifier is greater than the rating of the AC Mains circuit breaker the breaker will trip thus shutting the amplifier Off Turn the amplifier levels to minimum and reset the breaker to the up position to rese...

Страница 9: ...reo down mode routes Input 1 to Output 1 and Input 2 to Output 2 DIP SW position 4 5 Input sensitivity 0 775V 1V 32dB Note The same setting effects both channels 7 DIP Switches for Amplifier Load Configuration IMPORTANT Each Channel can have different speaker loads applied It is important to assign the load setting via this DIP switch This not only protects the amplifier but provides maximum perfo...

Страница 10: ...nd CC terminals A Contact Closure Using a latching contact switch short the Ground and CC ports together B DC Voltage Apply 5V 24V DC to these ports 9 Fault Reporting Terminals The HPA incorporates a fault reporting system to inform a system administrator if there is something wrong with the amplifier that needs to be attended to by a system technician The ports are shorted together NC Normally Cl...

Страница 11: ... 7 62mm pitch design and is connected to the chassis by the 2 incorporated screws It is recommended to use 14 18 gauge wire or larger for connection to the loudspeaker The terminals can accept wire sizes of 6 18 gauge Class 2 wiring Properly preparing the wire is critical to ensure a secure connection for safety and audio quality First strip the wire back 0 250 5mm We do not recommend tinning sold...

Страница 12: ... wire Selecting the AC Mains Source The HPA2408 is power consumption friendly compared to other multi channels amplifiers The HPA2408 features Generation II Class D Output topology that provides high efficiency amplification The power supply is a global use wide range voltage power supply The combination of the power supply and the highly efficient output stage collectively deliver exceptional dyn...

Страница 13: ...hat other products are connected to the same circuit 2 Never plug an HPA Series amplifier into a power strip Always connect directly to a dedicated circuit wall receptacle Power strips are not designed to deliver high amounts of continuous or peak current 3 Never plug an HPA Series amplifier into an extension cord Best Practices 1 Each HPA Series amplifier should have its own dedicated AC Mains li...

Страница 14: ...e 2 Remove the two screws M3 x 8mm Pan Head Black holding the HPA accessory blank panel Be careful and do not lose the screws 3 Remove the ribbon cable from the cover plate PCB connector 4 Connect the accessory card to the ribbon cable by carefully aligning the ribbon cable connector to the mating PCB connector If aligned correctly the cable will mate easily 5 Carefully guide the accessory card in...

Страница 15: ...0dBu Load Configuration 70V Inputs Input Quantity 8 Balanced Inputs Expandable to 16 via Accessory Card Input Type Balanced Line Input Connectors Type 3 5mm Euro Block Input Impedance 20KΩ Balanced 10KΩ Unbalanced Input Sensitivity 775mV 1 0V 32dB Selectable Maximum Input Level dBu Vrms 24dBu 12V Accessory Slot Refer to Accessory Card Specifications Accessory Slot 8 Input Dante Digital Card HPA DA...

Страница 16: ...er Voltage Shut Off Peak Current Limit Over Temp AC Power Requirements Operating Voltage Auto Switch 50 60Hz 100V 240V Minimum Power Up Voltage 95V Maximum Operating Voltage 258V AC Mains Source Breaker Required 120V 15A Minimum Dedicated to Achieve Full Power All 8 Channels Driven 220V 240V 10A Amplifier Internal AC Breaker 15A Continuous 30A Peak Mains Connector IEC C14 Lockable Receptacle Power...

Страница 17: ...he amplifier to achieve 100 of the 4Ω or 70 7V power rating Using Pink Noise for testing amplifiers is a strenuous test that provides a consistent signal across the entire audio spectrum Pink noise also provides a 6db Crest factor signal that injects a balance of RMS and peak signals providing realistic amp draw data for audio application 5 Max burst power draw is defined as follows 1 kHz sine wav...

Страница 18: ...k McKay Blvd Ennis TX 75119 800 876 3333 AtlasIED com 0 14 00 15 00 T SIDE Protect Limit Signal Ready Power Temp Standby 6 0 10 5 0 10 8 0 10 7 0 10 HPA2408 Multi Impedance Amplifier 5 0 0 2 6 3 2 CONFORMSTO UL STD 62368 1 CERTIFIEDTO CSA STD C22 2 No 62368 1 19 00 3 50 17 00 NOTES SCALE IS 1 5 0 FRONT Protect Limit Signal Ready Power Temp Standby 6 0 10 5 0 10 8 0 10 7 0 10 Protect Limit Signal R...

Страница 19: ... 19 HPA Series Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes ...

Страница 20: ...turned product s a written request for an estimate of repair costs before any nonwarranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with the transportation charges collect EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY ATLASIED SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR AN...

Отзывы: