ATLAS North America Proprietary
Sea Scan ARC Scout MKII Installation Guide
1 of 1
Page: 5
Issue: 1.1.0
SCTM2-INST
Installation Manual
3 Suggested Tools
In order to install your Sea Scan ARC Scout MkII system you may need some of the following tools.
·
Wire Cutter
·
Wire Stripper
·
Soldering Iron
·
Flux
·
Solder
·
Needle Nose Pliers
·
Heat Gun
·
#4-40 UNC Screws
4 System Installation Requirements
Power Supply:
Input Voltage
Input Power
Minimum
11.5 VDC
20 Watts (Peak)
Maximum
30 VDC
Absolute Maximum Rating
30.5 VDC
Typical Operating Power Consumption:
Input Voltage
Single Frequency Operation
Dual Frequency Operation
12V
4.0 W
6.5 W
16V
4.5 W
7.5 W
20V
5.5 W
9.8 W
24V
6.5 W
11.5 W
28V
7.5 W
13.0 W
30V
8.0 W
14.0 W
Input Voltage
Dual Frequency Idle
Sleep (Wake On LAN) Dual
Frequency
Sleep (Wake on Sync In)Dual
Frequency
12 VDC
4.3 W
3.7 W
2.6 W
16 VDC
4.0 W
4.0 W
2.4 W
20 VDC
6.0 W
4.3 W
2.5 W
24 VDC
6.3 W
4.7 W
2.7 W
28 VDC
6.9 W
5.1 W
2.9 W
30 VDC
7.1 W
5.4 W
3.1 W
Optically Isolated Interface:
Power Requirements
Parameter
Minimum
Nominal
Maximum
VDD
3 VDC
3.3 VDC
5.5 VDC
IDD
20 mA
20mA
-
Specifications
Input Level
TTL/LVTTL