- 96 -
Legislation
PARTS, SUBJECTED TO PRESSURE EQUIPMENT DIRECTIVE 97/23/EC, CAT. II AND ABOVE
Safety valve: cat. IV
Air Oil separator
Designation
XRXS 567 Cd - XRXS 1240 CD7
XRXS 607 Cd - XRXS 1275 CD7
XRVS 617 Cd - XRVS 1300 CD7
XRVS 647 Cd - XRVS 1350 CD7
Set pressure
bar(e)
35
30
psi
508
435
Design temperature
°C
130
130
°F
266
266
Designation
Standard
Cold start equipment
Design pressure
bar(e)
35
35
psi
508
508
Design temperature max.
°C
130
130
°F
266
266
Design temperature min.
°C
-25
-25
°F
-13
-13
Volume
l
143
143
US gal
37.7
37.7
Imp gal
31.5
31.5
cu.ft
5
5