- 36 -
Technical Specifications
Settings of Shutdown Switches and Safety Valve
Compressor
XAS 185 CD7
Temperature safety switch trip point
°F
248
°C
120
Safety valve effective opening pressure
psig
150
(bar)
10.3
(check stamping on valve)
Engine
XAS 185 CD7
Low oil pressure safety switch trip point
psig
12
(bar)
0.8
Temperature safety switch trip point
°F
233
°C
112
Compressor
Maximum effective pressure
psig
123
(bar)
8.5
Normal effective working pressure
psig
100
(bar)
7.0
Minimum effective working pressure
psig
58
(bar)
4.0
Typical oil content of the compressed air
mg/m3
<5
Free air delivery at working pressure,
cfm
185
l/s
87
Engine
XAS 185 CD7
Make
Caterpillar
Model
C2.2
Type
4CYL./NA
Maximum operating speed (compressor loaded) rpm
2750±20
Minimum operating speed (compressor unloaded) rpm
1550±50
Fuel consumption (at full load)
2.7 gal/hr
Fuel consumption (at unload)
1.0 gal/hr
Capacities
Compressor oil system
gal
2
ltr
7.4
Engine lube oil system with filter
gal
2.5
ltr
9.5
Fuel tank
gal
25
ltr
94
Engine cooling system
gal
2.5
ltr
9.2
Compressor/Engine Specifications
Maximum loading speed and reference conditions 1,2).
1. Reference conditions as specified are measured at the air inlet grating outside the
canopy:
-Air intake pressure (absolute) 1 bar (14.5 psi)
-Air intake temperature 20°C (68°F)
-Relative air humidity 0%
2. Free air delivery is measured according to ISO 1217 ed. 3 1996 annex D which
corresponds to American ANSI PTC9.
With a tolerance of +/- 5% 25 l/s<FAD<250 l/s
Содержание XAS 185 CD7 T4
Страница 1: ...XAS 185 CD7 T4 Instruction Manual for AC Compressors English Engine Caterpillar C2 2 ...
Страница 2: ......
Страница 6: ... 6 ...
Страница 14: ... 14 Main Parts ...
Страница 16: ... 16 Compressor regulating system Load Condition ...
Страница 20: ... 20 Electric system CIRCUIT DIAGRAM ...
Страница 30: ... 30 Adjustments and Servicing Procedures Adjustment of the Continuous Regulating System ...
Страница 38: ... 38 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 39: ... 39 Maintenance Log Compressor Customer Serial number Service hours Maintenance action Date By initials ...
Страница 40: ... 40 ...