- 31 -
STARTING/STOPPING
BEFORE STARTING
1. Before initial start-up, prepare battery for
operation if not already done. See section Battery
care.
2. With the compressor standing level, check the
level of the engine oil. Add oil, if necessary, up to
the upper mark on the dipstick. Consult the
Engine Operation Manual for the type and
viscosity grade of the engine oil.
3. Check the level of the compressor oil. See section
Compressor regulating system. The pointer of
the oil level gauge (OLG) should register in the
green range. Add oil if necessary. See section Oil
specifications for the oil to be used.
4. Check that the fuel tank contains sufficient fuel.
Top up, if necessary. Consult the Engine
Operation Manual for the type of fuel.
5. Drain any water and sediment from the fuel filter
until clean fuel flows from the drain cock.
6. Press vacuator valves (VV) of the air filters to
remove dust.
7. Check the air filter vacuum indicators (VI). If the
yellow piston reaches the red marked service
range, replace the filter element. Reset the
indicator by pushing the reset button.
8. Open air outlet valve to allow air flow to the
atmosphere.
Before removing the oil filler plug (FP),
ensure that the pressure is released by
opening an air outlet valve.
CONTROL PANEL
P1
Hourmeter
F1
Circuit Breaker Button
PG
Working pressure gauge
LV
Loading Valve
N4
Control Module
S
Start/Stop Button
H1
LED (green)
Fuel ON
H2
LED (green)
Preheat (option)
H3
LED (red)
Charge Indication
H4
LED (red)
Compressor Outlet Temperature
H5
LED (red)
Engine Oil Temperature
H6
LED (red)
Engine Oil Pressure
H7
LED (red)
Low Coolant
H8
LED (red)
Low Fuel
(PG)
(LV)
(H5) (H6) (H7)
(S)
(F1)
0 0 0 0
(H1) (H2) (H3) (H4)
(N4)
(P1)
(H8)