© Atlas Copco Industrial Technique AB - 9839 0326 01

If no detailed information about preventive maintenance is included, follow these general guide-
lines:

Clean appropriate parts accurately

Replace any defective or worn parts

Preventive maintenance

Recommended interval between actions:

Valid at normal usage of the tool at a load up to 70% of maximum torque.

Service should only be carried out by trained technician following provided service instructions and
using original Atlas Copco spare parts.

Interval

Action

1.500.000 cycles or 1 year

Calibrate the tool

1.500.000 cycles

Exchange bit grounding

3.000.000 cycles

Exchange front part

3.000.000 cycles

Exchange motor

Содержание QMC41-250-I06

Страница 1: ...al No B2410001 Product Instructions QMC41 250 I06 62 5 250 cNm 8432084464 Fixtured current controlled WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference ...

Страница 2: ...ta 4 Accessories 5 Bit run out test 5 Bit grounding test 5 Service Overview 5 Service Recommendations 5 Preventive maintenance 6 Installation 7 Installation Instructions 7 Installing the tool 7 Mechanical installation 7 Electrical installation 7 Operation 9 Ergonomic Guidelines 9 Operating Instructions 10 Mount bit 10 Service 11 Preventing ESD Problems 11 Maintenance Instructions 11 Service Recomm...

Страница 3: ... not related to personal injury Warranty Product warranty will expire 12 months after the product is first taken into use but will in any case ex pire at the latest 13 months after delivery Normal wear and tear on parts is not included within the warranty Normal wear and tear is that which requires a part change or other adjustment overhaul during standard tools maintenance typical for that period...

Страница 4: ...be found either in the Dimensional Drawings Archive or on ServAid Please visit http webbox atlascopco com webbox dimdrw or https servaid atlascopco com Overview Applications The MicroTorque screw fastening systems are ultra low torque applications Normal Environmental Conditions This product is designed to be safe under the following conditions Indoor use Altitude up to 2 000 m Operating temperatu...

Страница 5: ... bit out on a special bit 4216 2194 00 Bit run out limit is 0 15 mm Bit grounding test Bit grounding is measured by the ground circuit stability and resistance with the tool running at no load with a rotation speed of 200 rpm Resistance is measured between the special bit 4216 2194 00 and the outside of the tool connector and the resistance limit is 20 Ω Service Overview Service Recommendations Pr...

Страница 6: ...orn parts Preventive maintenance Recommended interval between actions Valid at normal usage of the tool at a load up to 70 of maximum torque Service should only be carried out by trained technician following provided service instructions and using original Atlas Copco spare parts Interval Action 1 500 000 cycles or 1 year Calibrate the tool 1 500 000 cycles Exchange bit grounding 3 000 000 cycles ...

Страница 7: ...ation Attach the tool to the fixture in one of the following ways A Using the threads at the front part accessible under the thread protection ring B Using the holes of the tool base Four holes are intended for screws and two holes are intended for guide pins Electrical installation Connect the tool to the drive using the supplied cable NOTICE Make sure the cable is not bent more than a radious of...

Страница 8: ...Installation EN QMC41 250 I06 8 Atlas Copco Industrial Technique AB 9839 0326 01 ...

Страница 9: ...orce Adjust for a convenient field of vision that requires minimal eye and head movements Use appropriate lighting for the work task Select the appropriate tool for the work task In noisy environments use ear protection equipment Use high quality inserted tools and consumables to minimize exposure to excessive levels of vibra tion Minimize exposure to reaction forces When cutting A cut off wheel c...

Страница 10: ...Operation EN QMC41 250 I06 10 Atlas Copco Industrial Technique AB 9839 0326 01 Operating Instructions Mount bit 1 Pull the chuck ring outwards 2 Insert the bit 3 Turn the bit if not seated properly ...

Страница 11: ...ailed information about preventive maintenance is included follow these general guide lines Clean appropriate parts accurately Replace any defective or worn parts Preventive maintenance Recommended interval between actions Valid at normal usage of the tool at a load up to 70 of maximum torque Service should only be carried out by trained technician following provided service instructions and using...

Страница 12: ... your national battery recovery organization Recycling information 1 Front protection Recycle as PA6 GF30 2 Cap nut Recycle as steel 3 Front part Recycle as steel 4 Grounding ring Recycle as CuSn6 5 Spring ring Recycle as steel 6 Cap nut Recycle as steel 7 Cover ring Recycle as TPU GF30 8 Main board Recycle as WEEE 9 Cap nut Recycle as steel 10 Motor Recycle as WEEE 11 Motor cover Recycle as alumi...

Страница 13: ...0326 01 13 15 Light module housing Recycle as aluminum 16 Reflector Recycle as POM 17 Part of light electronics Recycle as WEEE 18 Cover plate Recycle as stainless steel 19 Screws Recycle as stainless steel 20 Housing frame Recycle as aluminum 21 Screws Recycle as steel ...

Страница 14: ......

Страница 15: ......

Страница 16: ...authorized use or copying of the contents or part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings Use only authorized parts Any damage or malfunction caused by the use of unauthorized parts is not covered by Warranty or Product Liability Out of respect to wildlife and nature our technical literature is printed on environmentally friendly...