32
PTS 916 Cd
4.4.6
Warmup status
Manual start
Other actions and signals have no effect in this status.
Automatic start
Other actions and signals have no effect in this status.
S
Warnings
R
Are shown on the screen
A
Shutdowns
R
To start failure status (see
section 4.4.11)
A
Max. warmup time elapsed
R
Not Loaded status or Load/
Unload status (see section 4.4.7)
A
Emergency stop button
R
To emergency stop status (see
section 4.4.13)
A
↓
-button, press once
R
Set pressure - 0.1 bar
A
↑
-button, press once
R
Set pr 0.1 bar
A
↓
-button, press continuously
R
Set pressure - 0.1 bar/second
A
↑
-button, press continuously
R
Set pr 0.1 bar/second
A
Stop command
R
To stopping status (see section
4.4.10)
A
Power OFF switch
R
To stopping status (see section
4.4.10)
A
Auto load button
or Remote Load input
if Remote control mode
R
After the Warmup status, the
CCM will skip the Not Loaded
status and go directly to the
Load/Unload status (see section
4.4.8)
“Automatic load” will appear on
the screen
If min. Warmup time is elapsed:
S
Coolant = Warmup temperature R
To Not Loaded status (see
section 4.4.7)
or Load/Unload status (see
section 4.4.8)
If Auto Load button was pressed:
A
Manual load button
or Remote Load input
if Remote control mode
R
Auto Load condition is canceled
S
Warnings
R
Are shown on the screen
A
Shutdowns
R
To shutdown status (see section
4.4.12)
A
Max. warmup time elapsed
R
To Not Loaded status (see
section 4.4.7) or Load/Unload
status (see section 4.4.8)
A
Emergency stop button
R
To emergency stop status (see
section 4.4.13)
A
↓
-button, press once
R
Set pressure - 0.1 bar
A
↑
-button, press once
R
Set pr 0.1 bar
A
↓
-button, press continuously
R
Set pressure - 0.1 bar/second
A
↑
-button, press continuously
R
Set pr 0.1 bar/second
A
Stop command
R
To stopping status (see section
4.4.10)
A
Power OFF switch
R
To stopping status (see section
4.4.10)
A
Manual load button
or Remote Load input
if Remote control mode
R
After the Warmup status, the
CCM will go to the Not Loaded
status (see section 4.4.7) before
going to the Load/Unload status
(see section 4.4.8)
“Automatic load” will disappear
from the display
If min. Warmup time is elapsed:
S
Coolant = Warmup temp.
R
To Load/Unload status (see
section 4.4.8)
or Not Loaded status (see section
4.4.7)
If Manual Load button was pressed:
A
Auto load button
or Remote Load input
if Remote control mode
R
Manual Load condition is
canceled