Appendix
9836 3521 01
657
10.4 Configuration of the Conversion Box
The Conversion Box, which allows QMR and QMX spindles to be used together with PowerMACS 4000,
have had to be configured for a particular spindle type using the tool ToolsTalk Service. From
PowerMACS 4000 version 7.5.0 it is automatically configured by the PowerMACS system for the type of
spindle that is specified by the setup.
The programming of the Box is handled by the TC and takes place when any of the following two
situations occur:
The setup loaded to the TC specifies another spindle article number than the one that the Box
currently is configured for.
The TC detects that the value of one or more of a number of crucial parameters differs between
the Box and the PowerMACS setup (the calibration parameters are not included in the
comparison).
The TC indicates that it has programmed the Conversion Box by issuing one of the following events
depending on the outcome:
4234, Conv. Box: TC n, Box programmed successfully
4232, Conv. Box: TC n, Failed to program box with reference values from setup
Whenever the Box is programmed by the TC, or the TC detects that the Box has been replaced, it
requires that a Motortune is run for the spindle before it allows a cycle to be started. This is indicated by
the following events:
4231, Conv. Box: TC n, New box detected
4233, Conv. Box: TC n, Motortune is required and calibration is recommended
If Motortune is required the TC will remember that also if the power supply is cycled.
The only exception to this is the first time a TC connected to a correctly programmed Box is updated to
version 7.4.2. If all important parameters have the same values as stated by the latest spindle type
definition files, then Motortune is not required.
If the Box has been calibrated using an earlier TTPM version its checksum is most likely incorrect even
though all values are correct. This problem is also checked for and corrected the first time the TC is
upgraded to version 7.4.2 if a Box is connected at that time. When corrected the following warning event is
issued:
4235, Conv. Box: TC n, Checksum faults detected. Verify spindle calibration values
Please note that even if the checksum is automatically corrected you should verify that the calibration
values are correct.
Should a Box calibrated with an old TTPM version be connected to an upgraded TC at a later time then
the following events will be issued:
5262, TC 1, Error reading reference from spindle. Ref 1, Status 50
5262, TC 1, Error reading reference from spindle. Ref 1, Status 50
5262, TC 1, Error reading reference from spindle. Ref 2, Status 50
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...