Tightening
9836 3521 01
369
6.6
Bolt Monitoring
The Monitoring function is used to examine the result of a whole tightening cycle.
This is done using a buffer, called the Monitoring buffer, in which each element represents a given angle
interval measured from when monitoring is started. The buffer has a fix length of 8192 elements but its
resolution, i.e. the length that each element represents, can be configured by editing the settings for a
program.
Note!
It is possible to use a second monitoring buffer. To enable the second monitoring buffer check the
Use 2
nd
monitoring buffer
check box located in general program settings, see chapter: Program
Settings. The second monitoring buffer is sampled on the secondary angle and torque channels if
equipped.