Tightening
9836 3521 01
291
6.5.2.14 TI - Run until Time
Step type Id:
13
Parameters:
TI
(Time), DIR (Direction).
Function
:
Run spindle, in DIR direction, for TI seconds.
Trace
:
Time TI is shown as a vertical line in trace when Torque, Angle, Current or Current as
torque vs. Time is selected. Control parameters must be enabled in the trace form (see
View of trace curves).
6.5.2.15 E1 - Run Engage method 1
Step type Id:
14
Parameters:
TI (Time), T (Torque), TC (Current as Torque).
Function
:
Engage spindle, method 1. Run spindle reverse for TI seconds and then forward for TI
seconds or until torque T or current TC is reached.
Trace
:
Torque T is shown as a horizontal line from step start to step stop in trace when Torque vs.
Time is selected. Current C is shown as a horizontal line from step start to step stop in trace
when Current vs. Time is selected. Control parameters must be enabled in the trace form
(see
6.5.2.16 E2 - Run Engage method 2
Step type Id:
15
Parameters:
TC (Current As Torque), TI (Time), DIR (Direction).
Function
:
Engage spindle, method 2. Run spindle, in DIR direction, with maximum TC torque, until no
increase in angle for TI seconds.
Trace
:
TC is shown as a horizontal line from step start to step stop in trace when Torque vs. Time
is selected. Control parameters must be enabled in the trace form (see
6.5.2.17 NS - Run until next step
Step type Id:
17
Parameters:
DIR (Direction).
Function:
Run spindle, in DIR direction, until next step starts. Next step starts when all the other
spindles reach their next synchronization point. That is, this step is meaningful only if there
are other spindles executing normal steps at the same time.
Trace
:
There are no control parameters for this step type in trace.
Содержание PowerMACS 4000
Страница 1: ...User guide PowerMACS 4000 Atlas Copco Tools and Assembly Systems 9836 3521 01 2010 11 Edition 10 3 0...
Страница 2: ......
Страница 46: ...System Architecture 46 9836 3521 01...
Страница 127: ...Set Up and Maintenance 9836 3521 01 127 See chapter Station Set Up for a description of the parameters...
Страница 267: ...Tightening 9836 3521 01 267...
Страница 400: ...Tightening 400 9836 3521 01...
Страница 422: ...Peripheral Devices 422 9836 3521 01 When connected to a system the form will show show the signal values in realtime...
Страница 486: ...Peripheral Devices 486 9836 3521 01...
Страница 622: ...Peripheral Devices 622 9836 3521 01...
Страница 664: ...References 664 9836 3521 01...
Страница 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...