7.4.2
Photocell
Overview
P7.1..... Photocell
Measures the luminosity and can be
activated by sunlight.
P7........ Photocell sensitivity regulator
Is used for regulating the luminosity
sensitivity level of the photocell.
Setting the sensitivity regulator
The photocell sensitivity regulator is used for
regulating the luminosity sensitivity level of the
photocell.
When the red LED (1) on the regulator is blinking, the
regulator is reading the luminosity level measured by
the photocell.
There are 2 blinking levels:
– Level 1: slow blinking
The photocell detects there is enough light,
according to its set sensitivity level.
– Level 2: fast blinking
The photocell detects there is a prolonged
luminosity change that falls below the set
sensitivity level. Remote start will be triggered
and the floodlights of the light tower will switch
on automatically (if Remote start and Auto mode
are selected, see also “Operating the light tower”
on page 27).
The recommended value to set the regulator is at
50 Lux.
– < 50 Lux: the floodlights switch on.
– > 50 Lux: the floodlights switch off.
The luminosity level can be adjusted to a desired
higher/lower level, according to the specific operating
conditions of the light tower.
Q2
Q3
Q4
Q5
Q1
40A/30mA
Q6
X1
0
1
Q1
Q2 Q3 Q4 Q5 Q6
P7
P7.1
P7
A1 A2 12
50
75
100
25
1
LX
11 14
B1 B2
1
00_00_HiLight H4_EN.book Page 65 Monday, April 18, 2016 2:10 PM
Содержание HiLight H4 Kd ESF
Страница 2: ...00_00_HiLight H4_EN book Page 2 Monday April 18 2016 2 10 PM ...
Страница 76: ... 76 10 3 Average illumination versus distance 00_00_HiLight H4_EN book Page 76 Monday April 18 2016 2 10 PM ...
Страница 81: ... 81 Circuit diagrams 00_00_HiLight H4_EN book Page 81 Monday April 18 2016 2 10 PM ...
Страница 85: ... 85 00_00_HiLight H4_EN book Page 85 Monday April 18 2016 2 10 PM ...
Страница 90: ... 90 00_00_HiLight H4_EN book Page 90 Monday April 18 2016 2 10 PM ...
Страница 93: ...00_00_HiLight H4_EN book Page 93 Monday April 18 2016 2 10 PM ...
Страница 94: ......