![Atlas Copco GA 11 VSD Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/atlas-copco/ga-11-vsd/ga-11-vsd_instruction-book_3001653074.webp)
8
Problem solving
Warning
Before carrying out any maintenance, repair work or adjustment, press the stop button,
wait until the compressor has stopped, press the emergency stop button and switch off
the voltage.
For interventions in the compressed air circuit, close the air outlet valve and open the
manual condensate drain valves. Depressurise the compressor by opening the oil filler
plug one turn. Tighten the plug after completing the work.
For location of components, see sections:
•
•
•
Open and lock the isolating switch.
The air outlet valve can be locked during maintenance or repair as follows:
• Close the valve.
• Remove the screw fixing the handle with the wrench delivered with the
compressor.
• Lift the handle and turn it until the slot of the handle fits over the blocking edge on
the valve body.
• Fit the screw.
The operator must apply all relevant
.
Before electrical intervention
Wait for at least 6 minutes before starting any electrical repairs as dangerous high
voltage remains on the capacitors of the start and speed regulation unit during some
minutes after switching off the voltage.
Faults and remedies
If the alarm LED is lit or flashes, consult sections
-
Condition
Fault
Remedy
Condensate is not discharged
from condensate separator
during loading
Discharge flexible clogged
Check and correct as
necessary
Float valve malfunctioning
Remove float valve assembly,
clean and check
-
Condition
Fault
Remedy
Compressor air output or
pressure below normal
Air consumption exceeds air
delivery of compressor
Check equipment connected
Choked air filter element
Replace filter element
Solenoid valve malfunctioning
Replace valve
Oil separator clogged
Have element replaced
Air leakage
Have leaks repaired