![Atlas Copco GA 11 VSD Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/atlas-copco/ga-11-vsd/ga-11-vsd_instruction-book_3001653070.webp)
7.2
Air filter
Location of air filter
Air filter, GA 5 VSD up to GA 11 VSD
Procedure
1. Stop the compressor and close the air outlet valve. Switch off the voltage.
2. Remove the cover of air filter (AF) by turning it anti-clockwise. Remove the filter element. If
necessary, clean the cover.
3. Fit the new element and the cover.
4. After carrying out all service actions in the relevant ‘Service Plan’, reset the service warning;
see section
7.3
Oil and oil filter change
Warning
The operator must apply all relevant
.
Always drain the compressor oil at all drain points. Used oil left in the compressor can
contaminate the oil system and can shorten the lifetime of the new oil.
Never mix lubricants of different brands or types as they may not be compatible and the
oil mix will have inferior properties. A label, indicating the type of oil filled ex-factory, is
stuck on the air receiver/oil tank.
Instruction book
68
API161475
Содержание GA 11 VSD
Страница 1: ...INSTRUCTION BOOK API161475 GA 11 VSD ...
Страница 2: ......
Страница 24: ...Menu flow for GA 5 up to GA 11 VSD simplified Instruction book 22 API161475 ...
Страница 55: ...Position of oil level sight glass Instruction book API161475 53 ...
Страница 83: ......