5.2
Starting
Procedure
For the position of the air outlet valve and the drain connections, see sections
Before starting, always check the oil level. Top up as necessary.
Control panel Elektronikon® Graphic
Step
Action
-
Open the air outlet valve.
-
Check that the local/LAN switch is in
local
position
-
Switch on the voltage. Check that voltage on LED (6) lights up.
-
A warning and red LED will be active, indicating that the compressor is in
Emergency forced local
status
-
In the controller settings, navigate to Network>CAN and set the CAN address according to the number
of the compressor (see Airplant / dryer instruction book), then turn CAN
ON
. See figure below.
-
Refer to the Airplant / dryer instruction book on how to set up the ES-MED.
When the ES-MED is configured, switch the local/LAN switch to LAN.
-
Verify that the compressor is called by the ES-MED to build up pressure.
-
When pressure is above 80% of nominal pressure, refer to section
the warning.