Atlas Copco G2422-1 Скачать руководство пользователя страница 9

G2422-1

EN

Installation

© Atlas Copco Industrial Technique AB - 9839 0485 01

9

Installation

Installation requirements

Air quality

• For optimum performance and maximum product life we recommend the

use of compressed air with a maximum dew point of +10°C (50°F). We also
recommend to install an Atlas Copco refrigeration type air dryer.

• Use a separate air filter which removes solid particles larger than 30 mi-

crons and more than 90% of liquid water. Install the filter as close as possi-
ble to the product and prior to any other air preparation units to avoid pres-
sure drop.

Make sure that the hose and couplings are clean and free from dust before
connecting to the tool.

Both lubricated and lubrication free products will benefit from a small
quantity of oil supplied from a lubricator.

Air lubrication guide

Brand

Air lubrication

Atlas Copco

Optimizer (1 liter) 9090 0000 04

Q8

Chopin 46

Shell

Shell Air Tool Oil S2 A 320

Compressed air connection

WARNING Compressed air can cause serious injury

Always shut off the air supply, drain hose of air pressure and disconnect
the tool from air supply; when not in use, before making any adjustments
to the product - for example changing accessories, or when making re-
pairs.

WARNING Whipping hoses can cause serious injury

Always make sure that there are no damaged or loose hoses or fittings.

WARNING Compressed Air

High air pressure can cause severe damage and injury.

Do not exceed maximum air pressure.

For correct air pressure and hose size, see section 

Technical data

.

Make sure that the hose and couplings are clean and free from dust before
connecting to the tool.

Installation instructions

Installation of vibrating tools

It is recommended that a minimum length of 300 mm (12") of flexible hose for
compressed air is inserted between a vibrating tool and the quick-action cou-
pling.

Содержание G2422-1

Страница 1: ...A9810001 2017 11 25 Product Instructions G2422 1 20000 r min 20000 rpm 8423031247 WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result i...

Страница 2: ...EN G2422 1 2 Atlas Copco Industrial Technique AB 9839 0485 01...

Страница 3: ...ervice recommendations 8 Installation 9 Installation requirements 9 Air quality 9 Air lubrication guide 9 Compressed air connection 9 Installation instructions 9 Installation of vibrating tools 9 Oper...

Страница 4: ...4 Atlas Copco Industrial Technique AB 9839 0485 01 Lubricating guide 15 Dismantling Assembling instructions 15 Instructions for vane motor 15 Testing 17 Recycling 18 Recycling instruction 18...

Страница 5: ...azardous situation which if not avoided could result in minor or moderate injury NOTICE NOTICE is used to address practices not related to personal injury Warranty Product warranty will expire 12 mont...

Страница 6: ...ervaid atlascopco com For further information contact your Atlas Copco sales representative or e mail us at servaid support se atlascopco com Website Log in to Atlas Copco www atlascopco com You can f...

Страница 7: ...ctions The service must only be done by authorized workshops or qualified ser vice technicians WARNING Polymer hazard The vanes in this product contain PTFE a synthetic fluoropolymer Due to wear there...

Страница 8: ...commended at regular intervals See the detailed information on preventive maintenance If the product is not working properly take it out of service and inspect it If no detailed information about prev...

Страница 9: ...Air lubrication Atlas Copco Optimizer 1 liter 9090 0000 04 Q8 Chopin 46 Shell Shell Air Tool Oil S2 A 320 Compressed air connection WARNING Compressed air can cause serious injury Always shut off the...

Страница 10: ...ust for convenient field of vision by minimizing movement of the eyes and head during the work task Use the appropriate lighting for the work task Select the appropriate tool for the work task Use ear...

Страница 11: ...n serviced Do the free speed check with the grinding equipment removed Use a pressure regulator to prevent a too high air pressure which can cause overspeed Make sure that connections and the air hose...

Страница 12: ...machine make sure that the collet is tightened correctly Do a test run of every newly attached wheel in a safe position for 30 sec onds Use a barrier such as under a heavy work table to stop any poss...

Страница 13: ...the shank When fitting mounted wheels or burrs reduce the overhang by pushing the shank all the way into the collet Check also the recommendations given by the tool manufacturer Observe that increase...

Страница 14: ...enance If the product is not working properly take it out of service and inspect it If no detailed information about preventive maintenance is included follow these general guidelines Clean appropriat...

Страница 15: ...P 222 Shell Alvania EP2 Texaco Multifak EP2 Molycote BR2 Plus Dismantling Assembling instructions Instructions for vane motor WARNING Polymer hazard The vanes in this product contain PTFE a synthetic...

Страница 16: ...ng No 9835 5485 00 Ordering No D C 4080 0182 01 7 3 5 4080 0182 02 8 4 5 4080 0182 03 9 5 5 4080 0182 04 10 6 5 4080 0182 05 13 8 5 4080 0182 06 16 10 5 4080 0182 07 19 12 5 4080 0182 08 22 15 5 4080...

Страница 17: ...For further infor mation see ordering No 9835 5485 00 Ordering No D C 4080 0567 04 12 5 5 2 4080 0567 11 14 5 6 5 4080 0567 01 15 5 5 2 4080 0567 05 18 5 6 2 4080 0567 02 18 5 8 2 4080 0567 06 21 5 7...

Страница 18: ...01 Recycling Recycling instruction When a product has served its purpose it has to be recycled properly Dismantle the product and recycle the components in accordance with local legislation Batteries...

Страница 19: ......

Страница 20: ...rved Any unauthorized use or copying of the contents or part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings Use only authorized parts Any...

Отзывы: