Service
EN
G2422-1
14
© Atlas Copco Industrial Technique AB - 9839 0485 01
Service
Maintenance instructions
Maintenance and service instructions
The service must only be done by authorized workshops or qualified ser-
vice technicians.
WARNING Polymer hazard
The vanes in this product contain PTFE (a synthetic fluoropolymer). Due to
wear, there might be PTFE particles inside the product. Heated PTFE can
produce fumes which may cause polymer fume fever with flu-like symp-
toms, especially when smoking contaminated tobacco.
Health and Safety recommendations for PTFE must be followed when han-
dling vanes and other components:
►
Do not smoke when servicing this product
►
PTFE-particles must not come in contact with open fire, glow or heat
►
Motor components must be washed with cleaning fluid and not blown
clear with an air line
►
Wash your hands before starting any other activity
Service recommendations
Preventive maintenance is recommended at regular intervals. See the detailed
information on preventive maintenance. If the product is not working properly,
take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow
these general guidelines:
• Clean appropriate parts accurately
• Replace any defective or worn parts
Replacement of vanes
Replace the vanes in the motor when a power drop of the tool is experienced. If
the vanes are not replaced in time other motor parts may be damaged. For in-
creased life length of the vanes use an oil lubricator to dose oil into the air inlet.
Lubrication instructions
Rust protection and cleaning
Water in the compressed air can cause rust. To prevent rust we strongly recom-
mend to install an air dryer.
Water and particles can cause sticking of vanes and valves. This can be pre-
vented by installing an air filter close to the product to avoid pressure drop.
Before longer standstills always protect your tool by adding a few drops of oil
into the air inlet. Run the tool for 5–10 seconds and absorb any access oil at the
air outlet in a cloth.
NOTICE
Do not try to clear the air path using sharp tools.
The air inlet is equipped with a strainer. If this is punctured, foreign objects
may harm the valves, resulting in overspeed.