![Atlas Copco G 2 Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/atlas-copco/g-2/g-2_instruction-book_3001652045.webp)
This screen shows the number of loading actions (x1 or - if <x1000> lights up - x1000). In the
above example, the number of unload to load actions is 10100.
3.15 Calling up/resetting the service timer
Starting from the Main screen:
• Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <dAtA> and press Enter button (7) to enter the Data menu.
• Scroll Up or Down buttons (4-8) until <d.6> and <hrs> is shown.
• Press Enter button (7): the service timer is shown.
This screen shows the unit used (<hrs> or <x1000 hrs>) and the value. In the example shown,
the compressor has run 1191 hours since the previous service.
3.16 Calling up/modifying pressure band selection
Starting from the Main screen:
• Press Enter button (7) for 3 seconds to enter the Main menu.
• Select <ProG> and press Enter button (7) to enter the Programming menu.
• Scroll Up or Down buttons (4-8) to <reG.P> for regulation pressure.
• Press Enter button (7) to enter the submenu.
Instruction book
2920 7199 10
43
Содержание G 2
Страница 1: ...INSTRUCTION BOOK OIL INJECTED ROTARY SCREW COMPRESSORS G 2 G 3 G 4 G 5 G 7 ...
Страница 2: ......
Страница 15: ...2 2 Air flow Pack Air flow floor mounted Pack units Instruction book 2920 7199 10 13 ...
Страница 18: ...2 3 Oil system Oil system Pack Instruction book 16 2920 7199 10 ...
Страница 20: ...2 4 Cooling system Pack units Instruction book 18 2920 7199 10 ...
Страница 60: ...Start up Start up sheet Label on the top Instruction book 58 2920 7199 10 ...
Страница 92: ......
Страница 93: ......