Cause
There are surge voltages in the input power supply
Remedy
Contact us.
Cause
The drive output cable or motor is shorted to ground (the current short to
ground is charging the main circuit capacitor of the drive through the
power supply).
Remedy
Examine the motor main circuit cable, terminals, and motor terminal box, and
then remove ground faults.
Re-energise the drive.
Cause
The power supply voltage is too high.
Remedy
Decrease the power supply voltage to match the drive rated voltage.
Fault
oC - Overcurrent
Cause
The load is too heavy.
Remedy
Contact us.
Cause
Overheating caused damage to the motor or the motor insulation is not
satisfactory.
Remedy
Measure the motor insulation resistance and replace the motor if there is
electrical conduction or unserviceable insulation.
Cause
The motor main circuit cable is contacting ground to make a short circuit.
Remedy
Examine the motor main circuit cable for damage and repair short circuits.
Measure the resistance between the motor main circuit cable and the ground
terminal. If there is electrical conduct on, replace the cable.
Fault
CE - Modbus communication error
Cause
The communications cable wiring is incorrect.
Remedy
Correct wiring errors.
Cause
There is a short-circuit in the communications cable or the
communications cable is not connected.
Remedy
Repair short circuits and connect cables.
Replace the defective communications cable.
Cause
The communication protocol is not compatible.
Remedy
Examine the values set in H5-xx.
Examine the settings on the controller side and correct the difference in
communication conditions.