- 30 -
User manual 1634 - EN
Loria 6000 heat pump
"
range 35°C
A
+++
A
++
G
F
E
D
C
B
A
A
+
< 55%
≥ 55% ≥ 59% ≥ 61% ≥ 100% ≥ 107% ≥ 115% ≥ 123% ≥ 150% ≥ 175%
Product name
Loria 6004
Loria 6006
Loria 6008
Loria 6010
Reference
522911
522912
522913
522914
Seasonal space heating energy efficiency of
heat pump
181%
177%
173%
154%
Type of control ( * = outdoor sensor; ** = Room
appliance)
* Class II
** Class VI
* Class II
** Class VI
* Class II
** Class VI
* Class II
** Class VI
Bonus
2%
4%
2%
4%
2%
4%
2%
4%
Seasonal space heating energy efficiency of
package
under average climates
183%
185%
188%
190%
168%
170%
156%
158%
Package energy class
A+++
A+++
A+++
A+++
A+++
A+++
A++
A++
Seasonal space heating energy efficiency of
package
under warmer climates
238%
240%
236%
238%
234%
236%
203%
205%
Seasonal space heating energy efficiency of
package
under colder climates
NA
The energy efficiency of the combined product described herein may not correspond to its actual energy efficiency once installed in a
building, as this efficiency is influenced by other factors such as heat loss in the distribution system and the dimensioning of the products in
relation to the size and characteristics of the building
"
range 55°C
A
+++
A
++
G
F
E
D
C
B
A
A
+
< 30% ≥ 30% ≥ 34% ≥ 36% ≥ 75% ≥ 82% ≥ 90% ≥ 98% ≥ 125% ≥ 150%
Product name
Loria 6004
Loria 6006
Loria 6008
Loria 6010
Reference
522911
522912
522913
522914
Seasonal space heating energy efficiency of
heat pump
124%
128%
123%
114%
Type of control ( * = outdoor sensor; ** = Room
appliance)
* Class II
** Class VI
* Class II
** Class VI
* Class II
** Class VI
* Class II
** Class VI
Bonus
2%
4%
2%
4%
2%
4%
2%
4%
Seasonal space heating energy efficiency of
package
under average climates
129%
131%
130%
132%
127%
129%
116%
118%
Package energy class
A++
A++
A++
A++
A++
A++
A+
A+
Seasonal space heating energy efficiency of
package
under warmer climates
157%
159%
155%
157%
163%
165%
132%
134%
Seasonal space heating energy efficiency of
package
under colder climates
NA
The energy efficiency of the combined product described herein may not correspond to its actual energy efficiency once installed in a
building, as this efficiency is influenced by other factors such as heat loss in the distribution system and the dimensioning of the products in
relation to the size and characteristics of the building
8 3 Package sheet
Outdoor sensor included in the combined package
Controller class
II
Contribution to seasonal efficiency
2%
Room appliance references
076310
Controller class
VI
Contribution to seasonal efficiency
4%