background image

2-lines display

Scientific Calculator

with advance

statistical functions

Please read before using.

O

w

n

e

r'

M

a

n

u

a

l

AT-30i

Safety Precautions
Be  sure  to  read  the  following  safety  precautions  before 
using  this  calculator.  Keep  this  manual  handy  for  later 
reference.

Batteries
•  After  removing  the  batteries  from  the  calculator,  put 

them in a safe place where there is no danger of them 
getting into the hands of small children and accidently 
swallowed.

• Keep batteries out of the reach of children. If accidentally 

swallowed, consult with a physician immediately.

•  Never  charge  batteries,  try  to  take  batteries  apart,  or 

allow  batteries  to  become  shorted.  Never  expose 
batteries  to  direct  heat  or  dispose  of  them  by 
incineration.

• Misuse of batteries can cause them to leak acid that can 

cause  damage  to  nearby  items  and  creates  the 
possibility of fire and personal injury.

•  Always  make  sure  that  a  battery's  positive  (+)  and 

negative (–) sides are facing correctly when you load it 
into the calculator.

•  Remove  the  batteries  if  you  do  not  plan  to  use  the 

calculator for a long time.

• Use only the type of batteries specified for this calculator 

in this manual.

•  Do  not  mix  old  and  new  batteries.  Do  not  mix  alkaline, 

standard (carbon-zinc), or rechargeable (nickle cadmium) 
batteries.

• Battery Contains Mercury. Do Not Put in Trash. Recycle or 

Manage as Hazardous Waste.

Disposing of the Calculator
•  Never  dispose  of  the  calculator  by  burning  it.  Doing  so 

can  cause  certain  components  to  suddenly  burst, 
creating the danger of fire and personal injury.

•  The  displays  and  illustrations  (such  as  key  markings) 

shown  in  this  Owner's  Manual  are  for  illustrative 
purposes only, and may differ somewhat from the actual 
items they represent.

•  The  contents  of  this  manual  are  subject  to  change 

without notice.

Handling Precautions
•  Be  sure  to  press  the  "ON/AC"  key  before  using  the 

calculator for the first time.

•  Even  if  the  calculator  is  operating  normally,  replace  the 

battery at least once every three years. Dead battery can 
leak,  causing  damage  to  and  malfunction  of  the 
calculator. Never leave the dead battery in the calculator.

• The battery that comes with this unit discharges slightly 

during  shipment  and  storage.  Because  ofthis,  it  may 
require  replacement  sooner  than  the  normal  expected 
battery life.

•  Low  battery  power  can  cause  memory  contents  to  

become  corrupted  or  lost  completely.  Always  keep 
written records of all important data.

• Avoid use and storage in areas subjected to temperature 

extremes. Very low temperatures can cause slow display 
response,total  failure  of  the  display,  and  shortening  of 
battery  life.Also  avoid  leaving  the  calculator  in  direct 
sunlight, neara window, near a heater or anywhere else it 
might become exposed to very high temperatures. Heat 
can  cause  discoloration  or  deformation  of  the 
calculator's case, anddamage to internal circuitry.

•  Avoid  use  and  storage  in  areas  subjected  to  large 

amounts of humidity and dust. Take care never to leave 
the  calculator  where  it  might  besplashed  by  water  or 
exposed  to  large  amounts  of  humidity  or  dust.  Such 
elements can damage internal circuitry.

•  Never  drop  the  calculator  or  otherwise  subject  it  to 

strong impact.

•  Never  twist  or  bend  the  calculator.  Avoid  carrying  the 

calculator  in  the  pocket  of  your  trousers  or  other 
tight-fitting  clothing  where  it  might  be  subjected  to 
twisting or bending.

• Never try to take the calculator apart.
•  Never  press  the  keys  of  the  calculator  with  a  ball-point 

pen or other pointed object.

• Use a soft, dry cloth to clean the exterior of the unit. If the 

calculator  becomes  very  dirty,  wipe  it  off  with  acloth 
moistened in a weak solution of water and a mildneutral 
household  detergent.  Wring  out  all  excess  moisture 
before wiping the calculator. Never use thinner, benzine 
or other volatile agents to clean the calculator. Doing so 
can remove printed markings and damage the case.

Two-lines Display

You can simultaneously check the calculation formula and 
its  answer. The  first  line  displays  the  calculation  formula. 
The second line displays the answer.

Keys Layout

Before Starting Calculations

Operation Modes
When  using  this  calculator,  it  is  necessary  to  select  the 
proper mode to meet your requirements.  This can be done 
by  pressing  [MODE]  to  scroll  through  sub-menus.  Then 
select the appropriate mode by keying in the number.

Press  [MODE]  once  to  read  the  first  page  of  the  main 
menu.

Press  [MODE]  again. 

Press  [MODE]  further. 

 

Press "MODE" once more to leave the menu.

Calculation Modes
"COMP"
 mode : - general calculations, including function 
calculations can be executed.
"SD"  mode:-  standard  deviation  calculation  can  be 
executed. "SD" symbol appears in display.
"REG"  mode:-  regression  calculations  can  be  performed. 
"REG" symbol appears in display.

Angular Measurement Modes 
"DEG"  mode:-    specify  measurement  in  "degrees".  "D" 
symbol appears in display window.
"RAD"  mode:-  specify  measurement  in  "radians".  "R" 
symbol appears in display window.
"GRA"  mode:-  specify  measurement  in  "grads".  "G" 
symbol appears in display window.

 Display Modes
"FIX"
  mode:-  specify  number  of  decimal  places.  "Fix" 
symbol appears in display window.
"SCI"  mode:-  specify  number  of  significant  digits.  "Sci" 
symbol appears in display window.

"NORM" mode:- cancels "Fix" and "Sci" specifications.

Note:- 
• Mode indicators appear in the lower part of the display.
•  The  "COMP",  "SD",  and  "REG"  modes  can  be  used  in 

combination with the angle unit modes.

• Be sure to check the current calculation mode (COMP, SD, 

REG)  and  angle  unit  mode  (DEG,  RAD,  GRA)  before 
beginning a calculation.

Calculation Priority Sequence
Calculations  are  performed  in  the  following  order  of 
precedence:-
1. Coordinate transformation: Pol(x, y),Rec(r, 

)

2. Type A functions :-

These functions are those in which the value is entered 
and than the function key is pressed, such as x

2

, x

–1

, x!, 

º'''.

3. Powers and roots,  x

y

x

4. Fractions,  a

b

/

c

5. Abbreviated multiplication format in front of 

π

, memory 

name or variable name, such as 2

π

, 5A, 

π

A, etc.

6. Type B functions :-

These  functions  are  those  in  which  the  function  key  is 
pressed and then the value is entered such as 

3

, log, 

ln, e

x

, 10

x

, sin, cos, tan, sin

–1

, cos

–1

, tan

–1

, sinh, cosh, tanh, 

sinh

–1

, cosh

–1

, tanh

–1

, (–).

7.  Abbreviated  multiplication  format  in  front  of  Type  B 

functions, such as, 2

3, A log2, etc.

8. Permutation, combination,  nPr,  nCr
9. 

10. 

• When functions with the same priority are used in series, 

execution is performed from right to left for :-  e

x

ln

120 

 e

x

{ln(

120)}.  Otherwise, execution is from left to right.

• Operations enclosed in parentheses are performed first.

Stacks
This  calculator  uses  memory  areas,  called  "stacks",  to 
temporarily  store  values  (numeric  stack)  and  commands 
(command  stack)  according  to  their  precedence  during 
calculations.  The  numeric  stack  has  10  levels  and  the 
command  stack  has  24  levels.  A  stack  error  (stk  ERROR) 
occurs  whenever  you  try  to  perform  a  calculation  that  is 
so complex that the capacity of a stack is exceeded.

Error Loacator
Pressing  [

3

]  or  [

4

]  after  an  error  occurs  display  the 

calculation  with  the  cursor  positioned  at  the  location 
where the error occured.

Overflow and Errors
The  calculator  is  locked  up  while  an  error  message  is  on 
the display. Press [ON/AC] to clear the error, or press [

3

or [

4

] to display the calculation and correct the problem.

"Ma ERROR" caused by:-
•  Calculation  result  is  outside  the  allowable  calculation 

range.

• Attempt to perform a function calculation using a value 

that exceeds the allowable input range.

• Attempt to perform an illegal operation (division by zero, 

etc.).

Action
•  Check  your  input  values  and  make  sure  they  are  all 

within  the  allowable  ranges.  Pay  special  attention  to 
values in any memory areas you are using.

"Stk ERROR" caused by:-
•  Capacity  of  the  numeric  stack  or  operator  stack  is 

exceeded.

Action
• Simplify the calculation. The numeric stack has 10 levels 

and the operator stack has 24 levels.

• Divide your calculation into two or more separate parts.

"Syn ERROR" caused by:-
• Attempt to perform an illegal mathematical operation.
Action
• Press to display the calculation with the cursor located at 
the location of the error.  Make necessary corrections.
 
Number of Input/output Digits and Calculation Digits
The  memory  area  used  for  calculation  input  can  hold  79 
"steps".  One  function  comprises  one  step.    Each  press  of 
numeric or  

  , 

  ,  

  and  

 keys comprise one step.  

Though such operations as [SHIFT] [x!]  (x

–1

  key) require 

two  key  operations,  they  actually  comprise  only  one 
function, and, therefore, only one step.  These steps can be 
confirmed using the cursor.  With each press of the  [

3

] or 

[

4

key, the cursor is moved one step. 

Whenever you input the 73rd step of any calculation, the 
cursor changes from "_" to "

" to let you know memory is 

running  low.  If  you  still  need  to  input  more,  you  should 
divide you calculation into two or more parts.

When numeric values or calculation commands are input, 
they  appear  on  the  display  from  the  left.    Calculation 
results, however, are displayed from the right.

The  allowable  input/output  range  (number  of  digits)  of 
this  unit  is  10  digits  for  a  mantissa  and  2  digits  for  the 
exponent.  Calculations, however, are performed internally 
with a range of 12 digits for a mantissa and 2 digits for an 
exponent.

Example:  3 

 10

5

 

 7 =

3[EXP]5[

÷

]7[=]

3[EXP]5[

÷

]7[

]42857[=] 

Corrections
To make corrections in a formula that is being input, use 
the  [

3

and [

4

] keys to move to the position of the error 

and press the correct keys.
Example: To change an input of 122 to 123 :-
[1] [2] [2]

[

3

]

[3]

Example:  To change an input of cos60 to sin60  :-
[cos] [6] [0]

[

3

] [

3

] [

3

]

[sin]

If  after  making  corrections,  input  of  the  formula  is 
complete, the answer can be obtained by pressing  [ = ].  If, 
however, more is to be added to the formula, advance the 
cursor  using  the    [

4

]    key  to  the  end  of  the  formula  for 

input.

If  an  unnecessary  character  has  been  included  in  a 
formula,  use  the    [

3

]  and  [

4

]    keys  to  move  to  the 

position of the error and press the "DEL" key.  Each press 
of "DEL" will delete one command ( one step ).

Example:  To correct an input of 369 

 

 2 to 369 

 2 :-

369[

][

]2

[

3

][

3

][DEL]

If  a  character  has  been  omitted  from  a  formula,  use  the      
[

3

]  and  [

4

]    key  to  move  to  the  position  where  the 

character  should  have  been  input,  and  press  [SHIFT] 
followed  by  [INS]  key.    Each  press  of  [SHIFT]  [INS]  will 
create a space for input of one command.

Example:  To correct an input of 2.36

2

 to sin 2.36

2

 :-

2[•]36[x

2

]

[

3

][

3

][

3

][

3

][

3

]

[SHIFT][INS]

[sin]

When [SHIFT] [INS] are pressed, the space that is opened 
is displayed as "     ". The function or value assigned to the 
next key you press will be inserted in the    .  To exit from 
the  insertion  mode,  move  the  cursors,  or  press  [SHIFT] 
[INS]
 , or press [=].

Even  after  the  [=]  key  has  been  pressed  to  calculate  a 
result,  it  is  possible  to  use  this  procedure  for  correction.  
Press the [

3

] key to move the cursor to the place where 

the correction is to be made.

Arithmetic Operations & Parenthesis Calculations 
•  Arithmetic  operations  are  performed  by  pressing  the 

keys in the same order as noted in the formula.

• For negative values, press [(-)] before entering the value
• For mixed basic arithmetic operations, multiplication and 

division are given priority over addition and subtraction

• Assuming that display mode "Norm 1" is selected.
 

Percentage Calculations
Use the "COMP" mode for percentage calculations.

Specifying the Format of Calculation Results
You  can  change  the  precision  of  calculation  results  by 
specifying the number of decimal places or the number of 
significant digits.  You can also shift the decimal place of a 
displayed  value  three  places  to  the  left  or  right  for 
one-touch conversions of metric weights and measures.

Upon  power  up  reset,  the  display  format  is  defaulted  at 
"Norm1".  Each  time  when  you  press  "[MODE]  [MODE] 
[MODE] [3]"
 you can choose either "Norm 1" or "Norm 2" 
by keying in [1] or [2] respectively. 
Norm 1 :- all values less than 10

–2

 or greater than 10

9

 are 

automatically expressed as exponents.
Norm 2 :- all values less than 10

–9

 or greater than 10

9

 are 

automatically expressed as exponents.
Note: You cannot specify the display format (Fix, Sci) while 
the calculator is in Base-N mode.

Specifying the Number of Decimal Places
The  calculator  always  performs  calculations  using  a 
10-digit  mantissa  and  2-digit  exponent,  and  results  are 
stored  in  memory  as  a  12-digit  mantissa  and  2-digit 
exponent  no  matter  how  many  decimal  places  you 
specify.    Intermediate  results  and  final  results  are  then 
automatically  rounded  off  to  the  number  of  decimal 
places you have specified.
It should be noted that displayed results are rounded 
to the specified number of decimal places, but stored 
results are normally not rounded.
To  specify  the  number  of  decimal  places  (  Fix  ),  press 
"[MODE]  [MODE]  [MODE]  [1]"  and  then  a  value 
indicating the number of decimal places (0~9).

At this time, you should be able to see "Fix" on the display.  
The number of decimal places specified will remain in 

effect  until  "Norm"  (to  select  "Norm"  press  "[MODE] 
[MODE] [MODE] [3]"
) is specified or significant digits are 
specified using "[MODE] [MODE] [MODE] [2]".

[ON/AC] [MODE]

[MODE]

[MODE]

[1]

[4] (to specify 4 decimal places)

Reset to "Norm"
[ON/AC] [MODE]

[MODE]

[MODE]

[3]

[1]

Rounding the Intermediate Result
As  the  number  of  decimal  places  is  specified,  the 
intermediate  result  will  be  automatically  rounded  to  the 
specified  decimal  places.    However,  the  stored 
intermediate result is not rounded.  In order to match the 
displayed  value  and  the  stored  value,  [SHIFT]  [Rnd]  can 
be input.

You can compare the final result obtained in the previous 
example with the final result of the following example.

Specifying the Number of Significant Digits
This  specification  is  used  to  automatically  round 
intermediate  results  and  final  results  to  the  number  of 
digits you have specified.

As  with  the  number  of  decimal  places,  displayed  results 
are rounded to the specified number of digits, but stored 
results are normally not rounded. 

To  specify  the  number  of  significant  digits  (Sci.),  select 
[SCI]  in  the  sub-menu  "FIX/SCI/NORM"  and  then  you  are 
asked to enter a value indicating the number of significant 
digits (0~9) as below.
 

Note :  "0" indicating 10 significant digits.
Meanwhile,  the "Sci" indicator will appear on the display. 

Shifting the Decimal Place
You  can  use  the  key  [ENG]  to  shift  the  decimal  point  of 
the displayed value three places to the left or right.  Each 
3-place shift to the left is the same as dividing the value 
by  1000,  and  each  shift  to  the  right  is  the  same  as 
multiplying  by  1000.    This  means  that  this  function  is 
useful  when  converting  metric  weights  and  measures  to 
other metric units.

Memory
This  calculator  contains  9  standard  memories.   There  are 
two  basic  types  of  memories,  i.e.,  "variable"  memories, 
which are accessed by using the [STO] and [RCL]  keys in 
combination with the alphabets A, B, C, D, E, F, M, X and Y.  
The  "independent"  memory,  which  is  accessed  by  using 
the  [M+]  ,  [Shift]  [M–]  and  [RCL]  and  [M]  keys.  The 
independent  memory  uses  the  same  memory  area  as 
variable M.  
Contents of both the variable and independent memories 
are protected even when the power is turned OFF.

Variable memories
Up  to  9  values  can  be  retained  in  memory  at  the  same 
time, and can be recalled when desired.

Example:   Input 123 into memory "A" :-
[ON/AC] 123

[STO] [A]

[ON/AC]

[RCL] [A]

When  formulas  are  input,  the  result  of  the  formula's 
calculation is retained in memory.

Example:   Input the result of 123

456 into memory "B" :-

[ON/AC] 123 [

] 456

[STO] [B]

[ON/AC]

[RCL] [B]

If  a  variable  expression  is  entered,  the  expression  is  first 
calculated  according  to  the  values  stored  in  the  variable 
memories used in the expression.  The result is then stored 
in the variable memory specified for the result.
Example:   Input the results of A

B into memory "C" :-

[ON/AC] [ALPHA] [A] [

]

[ALPHA] [B]

[STO] [C]

[ON/AC]

[RCL] [C]

 
Deleting memories
To  delete  all  contents  of  variable  memories,  press  [Shift] 
followed by [Mcl] [=].

Independent Memory
Addition and subtraction (to and from sum) results can be 
stored directly in memory.  Results can also be totalized in 
memory,  making  it  easy  to  calculate  sums. The  icon  "M" 
will be lighted as long as M is not empty.
Example:  Input 123 to independent memory.
[ON/AC] [1] [2] [3]

[M+]

Recall memory data
[ON/AC]

[RCL] [M]

Add 25, subtract 12
25 [M+] 12 [SHIFT] [M–]

Recall memory data
[ON/AC]

[RCL] [M]

To clear memory contents, press  [0] [STO] [M].

Addition/subtraction  to  or  from  sum  in  memory  cannot 
be carried out with [M+][SHIFT] [M–] keys in "SD" mode 
and "REG" mode.

Difference between [STO][M] and [M+], [SHIFT][M–] :-
Both  [STO]  [M]  and  [M+],  [SHIFT]  [M–]  can  be  used  to 
input  results  into  memory,  however  when  the  [STO]  [M] 
operation is used,  previous memory contents are cleared.  
When either [M+] or [SHIFT] [M–] is used, value is added 
or subtracted to or from present sum in memory.

Example:  Input  456  into  memory  "M"  using  [STO]  [M] 
procedure. Memory already contains value of 123.
[ON/AC] [1] [2] [3] [STO] [M]

[ON/AC] [4] [5] [6] [STO] [M]

[ON/AC]

[RCL] [M]

Example: Input 456 into memory "M" using M+.  Memory 
already contains value of 123.
[ON/AC] [1] [2] [3] [STO] [M]

[ON/AC] [4] [5] [6] [M+]

[ON/AC]

[RCL] [M]

Special Functions

Answer Function
This unit has an answer function that stores the result of 
the  most  recent  calculation.  Once  a  numeric  value  or 
numeric  expression  is  entered  and  [=]  is  pressed,  the 
result is stored by this function.

To  recall  the  stored  value,  press  the  [Ans] [=]  key.   When 
[Ans] is pressed, "Ans" will appear on the display, and the 
value can be used in subsequent calculations.

Example:  123

456 = 579

                     789

579 = 210

[ON/AC][1][2][3][

][4][5][6][=]

[7][8][9][

][Ans]

[=]

Numeric values with 12 digits for a mantissa and 2 digits 
for an exponent can be stored in the "Ans" memory.  The 
"Ans" memory is not erased even if the power of the unit 
is turned OFF.  Each time [=] , [Shift] [%] , [M+] , [Shift] [M–] , 
and [STO] 

 (

 = A ~ F, M, X, Y ) is pressed, the value in the 

Ans memory is replaced with the new value produced by 
the  calculation  execution.    When  execution  of  a 
calculation results in an error, however, the "Ans" memory 
retains its current value.  
Note:-  Contents of "Ans" memory are not altered when 
RCL 

  (

  =  A~F,  M,  X,  Y)  is  used  to  recall  contents  of 

variable memory.  Also, contents of "Ans" memory are not 
altered when variables are input when the variable input 
prompt is displayed.

Omitting the multiplication sign (

)

When inputting a formula as it is written, from left to right, 
it  is  possible  to  omit  the  multiplication  sign  (

)  in  the 

following cases :-

• Before the following functions :-

sin,  cos,  tan,  sin

–1

,  cos

–1

,  tan

–1

,  sinh,  cosh,  tanh,  sinh

–1

cosh

–1

, tanh

–1

, log, ln, 10

x

, e

x

3

, Pol(x,y), Rec(r, 

)

example:  2sin30, 10log1.2, 2

3, 2Pol(5, 12), etc.

• Before fixed numbers, variales and memories :-

example:  2

π

, 2AB, 3Ans, etc.

• Before parentheses :-

example:  3(5

6), (A

1)(B

1), etc.

Continuous Calculation Function
Even  if  calculations  are  concluded  with  the  [=]  key,  the 
result  obtained  can  be  used  for  further  calculations.    In 
this case, calculations are performed with 10 digits for the 
mantissa which is displayed.

Example:    To  calculate 

3.14  continuing  after  3

4=12 

[ON/AC] [3] [

] [4] [=]

(continuing) [

] [3] [•] [1] [4]

[=]

Example:  To calculate 1

3

3 =

[AC] [1] [

] [3] [

] [3] [=]

[1] [

] [3] [=]

(continuing) [

] [3] [=]

This function can be used with Type A functions ( x

2

, x

–1

x!), 

, x

y,

 

x

 and º' ". 

Example: Squaring the result of  78

6=13

[ON/AC] [7] [8] [

] [6] [=]

(continuing) [x

2

]

[=]

Replay Function
This  function  stores  formulas  that  have  been  executed.  
After  execution  is  complete,  pressing  either  the  [

3

]  or  

[

4

] key will display the formula executed.

Pressing [

4

] will display the formula from the beginning, 

with the cursor located under the first character.
Pressing  [

3

]  will  display  the  formula  from  the  end,  with 

the  cursor  located  at  the  space  following  the  last 
character.  After this, using the [

4

] and [

3

] to move the 

cursor, the formula can be checked and numeric values or 
commands can be changed for subsequent execution.

Example: 
[ON/AC] [1] [2] [3] [

]

[4] [5] [6] [=]

[

4

]

[=]

[

3

]

hyp  M  STO  RCL  SD  REG 

Fix  Sci

S A

D R G

– 1 –

– 2 –

– 3 –

– 4 –

– 8 –

– 12 –

– 16 –

– 9 –

– 13 –

– 17 –

– 10 –

– 14 –

– 18 –

– 11 –

– 15 –

– 19 –

– 5 –

– 6 –

– 7 –

3

E

5

÷

7

42857.14286

D

123_

0.

D

A=

123.

D

_

0.

D

A=

123.

D

123X456_

0.

D

B=

56088.

D

_

0.

D

B=

56088.

D

3

E

5

÷

7–42857

0.1428571

D

369xx2_

D

0.

2.36

2

_

D

0.

369x2

D

0.

2.36

2

D

0.

 .36

2

D

0.

sin  .36

2

D

0.

 

 

Display

Example 

Operation 

(Lower)

Percentage
26% of $15.00
Ratio
75 is what % of 250?

15 [

]26 [SHIFT] [%]

75[

]250 [SHIFT] [%]

3.9

30.

Sci 0~9?

 

 

Display

Example 

Operation 

(Lower)

100

6 = 16.66666666

specify 5 significant
digits
Cancel specification by
specifying "Norm" again.

100[

]6 [=]

[Mode][Mode][Mode][2][5]

[Mode][Mode][Mode][3][1]

16.66666667

1.6667

01

16.66666667

 

 

Display

Example 

Operation 

(Lower)

123m

456 = 56088m

 

= 56.088km

78g

0.96  = 74.88g

 

= 0.07488kg

123[

]456 [=]

[ENG]
78[

]0.96 [=]

[SHIFT] [ENG]

56088.

56.088

03

74.88

0.07488

03

AXB_

0.

D

78

÷

6

13.

D

Ans

2

_

13.

D

Ans

2

169.

D

123x456

56088.

D

123x456

56088.

D

123x456_

56088.

D

C=

6898824.

D

_

0.

D

C=

6898824.

D

123_

0.

D

123

123.

D

_

0.

D

_

0.

D

M=

123.

D

M=

136.

D

M=

M

M

M

M

M

M

M

M

123.

D

M=

456.

D

_

0.

D

M=

456.

D

M=

123.

D

456

456.

D

_

0.

D

M=

579.

D

123+456

579.

D

789–Ans_

579.

D

789–Ans

210.

D

3x4

12.

D

Ans

÷

3.14_

12.

D

Ans

÷

3.14

3.821656051

D

1

÷

3x3

1.

D

1

÷

3

0.333333333

D

Ansx3

1.

D

12

12.

D

123x456

56088.

D

0

1

2

3

EXP

Ans

DEL

ON/AC

=

+

4

5

6

7

8

9

+

÷

STO

RCL

(

)

,

;

M+

º

,,,

hyp

sin

cos

tan

tan

–1

M–

DT

cos

–1

ln

log

a

b

/c

d/c

3

x

10

x

e

x

ENG

x

y

x

–1

x

3

x

2

nCr

Pol(

nPr

Rec(

x

!

(–)

SHIFT

OFF

ALPHA

REPLAY

MODE

Rnd

Ran#

%

DRG

π

x

A

B

C

r

X

Y

M

Scl

INS

Mcl

x

n

x

n

–1

x

y

y

y

n

y

n

–1

F

E

sin

–1

D

C

B

A

CL

COMP SD REG

1   2   3

Deg Rad Gra

1   2   3

Fix Sci Norm

1   2   3

_

0.

122_

D

0.

122

D

0.

123_

D

0.

cos 60

D

0.

sin 60

D

0.

cos 60

D

0.

COMP SD REG

1   2   3

Deg Rad Gra

1   2   3

D

Fix

_

0.0000

Norm 1~2?

Fix Sci Norm

1   2   3

COMP SD REG

1   2   3

Deg Rad Gra

1   2   3

Fix Sci Norm

1   2   3

Fix 0~9?

 

 

Display

Example 

Operation 

(Lower)

100

6 = 16.66666666

specify 4 decimal places
cancel specification

200

7

14 = 400

rounded to 3 decimal
places

100 [

] 6 [=]

[MODE][MODE][MODE][1][4]
[MODE][MODE][MODE]
[3] [1]
200[

]7 [

] 14[=]

[MODE][MODE][MODE][1][3]

200 [

] 7[ =]

The intermediate result is
automatically  rounded
to the specified three
decimal  places.

16.66666667

16.6667

            

16.66666667

            400.

            400.000

28.571

 

 

Display

Example 

Operation 

(Lower)

The stored 10-digit
result (28.571421857) is
used when you continue
the calculation by simply
pressing [

] or any other

arithmetic function key.

Cancel specification by
specifying "Norm" again.

[

]

14 [=]
(The final result is
automatically  rounded to
the specified three
decimal  places.)
[MODE][MODE][MODE][3][1]

Ans 

            

(upper display)

400.000

400.

Fix 0~9?

 

 

Display

Example 

Operation 

(Lower)

200

7

14 = 400

rounded to 3 decimal
places

round the stored 
intermediate result to
the specified three 
decimal places

Cancel specification by
specifying "Norm" again.

200[

]7 [

] 14[=]

[MODE][MODE][MODE][1][3]

200[

]7 [=]

The intermediate result is
automatically  rounded
to the specified three
decimal  places.
[SHIFT] [Rnd]

[

]

14 [=]
[MODE][MODE][MODE][3][1]

400.

400.000

28.571

28.571

Ans 

            

(upper display)

399.994
399.994

 

 

Display

Example 

Operation 

(Lower)

23 + 4.5 –53 =–25.5
56

(–12)

(–2.5)=268.8

12369

7532

74103= 

6.903680613

10

12

(4.5

10

75

)

(–2.3

10

–79

) =  –1.035

10

–3

(2+3)

10

2

=500

(1

10

5

)

7=

14285.71429
(1

10

5

)

7

14285=

0.7142857 
please note that internal calculation is calculated
in 12 digits for a mantissa and the result is
displayed and rounded off to 10 digits. 
 3 + 5 

 

6 = 33

 7 

 8 

 4 

 5 = 36

 1 

 2 

 3 

 4 

 5 

 6

= 6.6
100 

 (2

3) 

 4 = 80

 3 

 ( 4 

 5 ) = 29

( 7 

 2 ) 

 ( 8 

 5 ) = 65

10 

 { 2 

 7 

 ( 3 

 6 )}

= –55

23 [

] 4.5 [

] 53 [=]

56[

][(–)]12[

][(–)]2.5[=]

12369[

] 7532 [

]

74103[=]
4.5[EXP]75 [

] [(–)]2.3

[EXP] [(–)]79 [=]
[( ] 2 [

] 3[ )][

10[

x

2

] [=]

1[EXP]5 [

] 7 [=]

1[EXP]5[

]7 [

]

14285 [=]
 
 
 
3 [

] 5 [

] 6 [=]

7 [

] 8 [

] 4 [

] 5 [=]

1 [

] 2 [

] 3 [

] 4 [

]

5 [

] 6 [=]

100 [

][( ] 2 [

] 3[ )]

[

] 4 [=]

2 [

] 3 [

] [(] 4 [

] 5 [=]

Closed parentheses
occurring immediately
before operation of the
[=] key may be omitted.
[( ] 7 [

] 2 [ )][( ] 8 [

] 5 [=]

A multiplication sign [

]

occurring immediately
before an open parantheses
can be omitted.
10 [

][( ] 2 [

] 7 [( ] 3 [

]

6 [=]

–25.5
268.8

6.903680613

12

–1.035

–03

500.

14285.71429

0.7142857

 
 
 

33.
36.

6.6

80.
29.

65.

–55.

All manuals and user guides at all-guides.com

all-guides.com

Отзывы: