INSTALLATION INSTRUCTIONS
210-0197_Libretto_TX_ATI_2020-02_ATI-eng
10
ed. 2020-02
12 INSTALLATION
TO AVOID DAMAGE THE TRANSACTION MUST BE CARRIED OUT BY A QUALIFIED
Before installing the appliance, ensure that the nominal supply voltage is 230 V - 50 Hz.
Make sure that the electrical system is adapted to deliver, in addition to the operating current required by the
unit, also the necessary current for powering appliances and equipment already in use.
Make the electrical connections in accordance with national laws and regulations.
Upstream of the unit to provide a single-pole switch with a minimum distance of 3.5 mm contacts.
The installation of the device is divided into 5 distinct phases, listed below, to be followed with attention and respecting
the order.
1. Positioning device
2. Installing break-wind hood device
3. Water connections
4. Connection gas circuit
5. Electrical connection
You should always make the grounding of the unit. Check that the power cord is in perfect condition. Under no
circumstances must repair the cable, possibly damaged, with tape or clamps. If the power cord is damaged, it must be
replaced by service agent or a similarly qualified person in order to avoid a hazard.
Incorrect installation can cause damage to people and things for which the manufacturer can not be held
responsible.
13 POSITIONING APPARATUS
The device, being of a type B, is expected to be connected to a duct for evacuation of the combustion products
towards the outside of the room; the combustion air is drawn directly into the environment where the device itself is
installed.
CAUTION
This unit can be installed and operated in permanently ventilated areas.
CAUTION
: Make sure the structure can support the weight of the device fully
CAUTION
: The device must be placed in a stable position
E 'recommended to place the device in order to facilitate the installation and maintenance operations. For this
purpose, the minimum distances indicated in the figure:
The front and right of the appliance must be easily accessible, in order to facilitate an easy periodical maintenance. It
is also necessary to avoid placing inflammable material in the vicinity of the appliance, in particular the front (leave at
least 50 cm from the burner) and close to the break-wind hood device.