Installation and Operation Manual
Document #9620-20-b-mc-16 base tool changer-07
Pinnacle Park
•
1031 Goodworth Drive
•
Apex, NC 27539
•
Tel: 919.772.0115
•
Fax: 919.772.8259
•
www.ati-ia.com
•
Email: [email protected]
B - 12
4.4 Electrical Module Pin Block Contact Inspection and cleaning
1.
Inspect the Master and Tool pin blocks for any debris or darkened pins.
Figure 4.3 —Inspect Master and Tool Pin Blocks
2.
If debris or darkened pins exist, remove debris using a vacuum, and clean using a nylon brush
(ATI part number 3690-0000064-60).
3.
Inspect the Master and Tool pin blocks for stuck pins or severe pin block damage.
Figure 4.4 —Stuck Pin and Pin Block Damage
4.
If stuck pins or severe pin block damage exists, contact ATI for possible pin replacement
procedures or module replacement.
4.5 Electrical Module Seal Inspection and Replacement
The seal protect the electrical connection between the Master and Tool module. If the seal
becomes worn or damaged it needs to be replaced.
1.
To remove the existing seal, pinch edge of seal with fingers and gently pull the seal away from the
pin block on the Master.
2.
Pull the seal off the pin block.
NOTICE:
Do not use an abrasive media, cleaners, or solvents to clean the contact pins.
Using abrasive media, cleaners, or solvents will cause erosion to the contact surface.
Clean contact surfaces with a vacuum or non-abrasive media such as a nylon brush
(ATI part number 3690-0000064-60).