® Urheberrecht ATH-Heinl GmbH & Co. KG, 2017, Alle Rechte vorbehalten. / Druckfehler und technische Änderungen vorbehalten / Stand: 01/2022
- 22 -
Hold them there and press the button
4
Set the value d with the
or
buttons (e.g.: 16 inches = 16).
>
5 Now pull the gauge out until it touches
the edge of the rim, hold it there and
press the button
>
100g Calibration
If the balancing machine indicates a residual unbalance after the test, the 100g calibration must be
performed.
1
Clamp a steel wheel with the possibility
of attaching weights. Enter the a, b, d
values. Press and hold the button
and press the button
.
>
2
Close the wheel guard or press the
button
to start the first balancing
process. As soon as the wheel stops,
turn it until all the position lights on the
outside are lit and place the 100g at the
12 o'clock position.
>
3
Close the wheel guard or press the
button
to start the second
balancing process. As soon as the wheel
stops, turn it until all the position lights
on the inside are lit and remove the 100g
from the outside and place it on the 12
o'clock position of the inside.
>
4
Close the wheel guard or press the
button
to start the last balancing
process. As soon as the wheel stops, the
calibration is complete.
>