background image

6/12 

 

Prior to 

use

 

2.1  Selection of right equipment 

You need to be sure that the equipment you intend to take into explosion-hazardous area matches 
up  with  the  zone  classification  and  other  safety  requirements  related.  The  operator  is  solely 
responsible  for  the  correct  selection  and  use  of  the  equipment  at  his  site.  At  least  the  following 
points should be notified prior to use. 

2.2  Intended purpose of equipment 

Please  keep  in  mind  what  the  actual  application  of  equipment  is.  For  example  in  case  the 
equipment is to be moved when connected to the supply it needs to be designed for that purpose. 
If  the  certification  is  mentioning  “portable”  it  means  that  the  equipment  is  suitable  and  tested  for 
portable use. If the certification does not mention portable it means that the equipment shall not be 
moved when it is in operation (reliable fixing of equipment). 

SLAM Star is designed and tested for portable use 

2.3  Application of use (Zone XX) in accordance with equipment category 

Operator has the best knowledge of area classification at his site. To help the operators’ selection 
of equipment the certification is describing the equipment category. For explosion hazardous areas 
there are three equipment categories. 

  Category 1 product is suitable for use in Zones 0, 1 and 2 / (20, 21 and 22) 

  Category 2 product is suitable for use in Zones 1 and 2 / 21 and 22 

  Category 3 product is suitable for use in Zones 2 / (22) 

SLAM Star is Category 2 equipment 

2.4  Explosion group (IIA, IIB or IIC) in accordance with Equipment group (IIA, 

IIB or IIC) 

This  information  is  vital  because  different  substances  require  varied  amount  of  energy  to  be 
ignited.  Safety  requirements  for  equipment  are  not  the  same  for  different  substances  (e.g.  static 
electricity  requirements).  Therefore  making  the  selection  easier  the  gases  are  divided  to  three 
different  groups  (IIA,  IIB  and  IIC).  Further  information  about  the  substances  can  be  found  from 
EN/IEC  60079-20-1  (Data  for  flammable  gases  and  vapours,  relating  to  the  use  of  electrical 
apparatus). 

SLAM Star belongs to Equipment group IIC 

2.5  Temperature class of the equipment 

Please  observe  the  Ignition  Temperature  (IT)  of  the  substance  creating  the  explosion  hazard  at 
your site. Select the equipment based on IT of the substance. The temperature of the equipment 
must  be  lower  than  IT.  The  highest  temperature  of  the  equipment  is  specified  by  using 
Temperature Classes T1 to T6. 

Example 

Petroleum ignition temperature is approximately 250°C 

à

 Maximum allowed temperature class of 

the equipment is T3 (< 200° C)

 

Содержание SLAM Star

Страница 1: ...Instructions for Safe Use Star Certification N o VTT 15 ATEX 077X and IECEx by VTT Thank you for choosing SLAM Star portable work light for your job site Purpose of this manual is to provide you all...

Страница 2: ...e with Equipment group IIA IIB or IIC 6 2 5 Temperature class of the equipment 6 2 6 Environmental criteria 7 3 Operating instructions 8 3 1 Personnel 8 3 2 Storage 8 3 3 Before first use 8 3 4 Visual...

Страница 3: ...ndependent from each others Under failure of one control gear the others still continue operating Low voltage protection smart feature brings reliability and convenience for use especially when operat...

Страница 4: ...losion hazardous areas II Certified for use in areas excluding mines 2 Equipment category suitable for Zone 1 and Zone 2 G Certification taking account explosion hazardous GASES Explanation of marking...

Страница 5: ...The test report typically specifies the following tests PE resistance test The purpose of this test is to measure persistence of earth conductor Vital test for electrical safety as well as explosion s...

Страница 6: ...plosion hazardous areas there are three equipment categories Category 1 product is suitable for use in Zones 0 1 and 2 20 21 and 22 Category 2 product is suitable for use in Zones 1 and 2 21 and 22 Ca...

Страница 7: ...on is valid for temperatures between 20 C 40 C If the equipment is used in other temperatures the safety cannot be guaranteed Selection and use of equipment is always under the responsibility of the o...

Страница 8: ...LAM Star units are designed to be used together with step down transformers Using SLAM Star unit with transformers of 2 pole socket outlets without grounding bonding imposes certain extra requirements...

Страница 9: ...tar units may be equipped with Ex certified socket in the factory Sockets are considered optional so they are added to the unit upon customer s special request In built sockets are recommended when th...

Страница 10: ...luminaries to a longer chain than 66 m measured from the protective fuse when the electrical supply is protected with C curve fuse Please refer to local applicable laws and requirements for electrical...

Страница 11: ...greater than 100 cm2 the part has to be changed The surface resistance of the transparent parts has to be between 1 M 1 G Please contact Atexor in case you need a simple measuring device which is nee...

Страница 12: ...e day Please study at least the following standards EN IEC 60079 14 Electrical installations in hazardous areas EN IEC 60079 10 Classification of hazardous areas EN IEC 60079 17 Inspection and mainten...

Отзывы: