9/16 

 

 

 

2.1.4 Temperature class of the equipment

 

 
Please observe the Ignition Temperature (IT) of the substance creating the explosion hazard 
at  your  site.  Select  the  equipment  based  on  IT  of  the  substance.  The  temperature  of  the 
equipment must be lower than IT. The highest  temperature of the equipment  is specified by 
using Temperature Classes T1 to T6. 
  
Example:  
 
Petroleum  ignition  temperature  is  approximately  250  Celsius 

  Maximum  allowed 

temperature class of the equipment is T3 (< 200° C) 
 

 

Slam®units with 

Fluorescent tube

 mentioned in this instruction are Temperature Class T3 (GASES) 

 

 

Slam®units with 

LED modules

 mentioned in this instruction are Temperature Class T4 (GASES) 

 

 

Slam®-units with fluorescent tube and LED modules mentioned in this instruction are having maximum 
surface temperature of 90

C (DUSTS) 

 

2.1.5 Environmental criteria 

 
Please  observe  the  ambient  temperature  of  the  application  in  use  because  certification  is 
valid for temperatures between 

– 20°C --- + 40°C. Some Slam®Hornet luminaries are certified 

for temperatures between 

– 40°C --- + 40°C. Please see type label of the product for further 

data.  If  the  equipment  is  used  in  other  temperatures  than  mentioned  the  safety  can  not  be 
guaranteed. 
  

Selection  and  use  of  equipment  is  always  under  the  responsibility  of  the  operator. 
Please note that all of the aforementioned criteria are to be fulfilled when selecting the 
equipment. 
 
Please do not take any unnecessary risks! 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание Slam Hornet 1 LED A

Страница 1: ...08 ATEX 066 or IECEx VTT 12 0009 Thank you for choosing Slam Hornet portable work light for your job site Purpose of this manual is to provide you all the necessary safety and product information to...

Страница 2: ...IA IIB or IIC in accordance with Equipment group IIA IIB or IIC 8 2 1 4 Temperature class of the equipment 9 2 1 5 Environmental criteria 9 3 Operating instructions 10 3 1 Personnel 10 3 2 Visual Insp...

Страница 3: ...et 2 LED Slam Hornet Linear 2x18W Slam Hornet Linear 2x36W Slam Hornet Linear 2 LED Dimensions mm Product model L Slam Hornet 1x18W 335 115 Slam Hornet 1x36W A Slam Hornet 1 LED A 540 115 Slam Hornet...

Страница 4: ...sion hazardous GASES D Certification taking account explosion hazardous DUSTS Explanation of marking for explosion hazardous area due to Gases e g Ex emb IIC T3 Gb Ex Certified for use in explosion ha...

Страница 5: ...ation or during expected malfunctions 1 3 Standard unit construction The following list familiarizes you with some common unit features important to recognize End parts Flexible plastic made end parts...

Страница 6: ...nts of own Socket Optional in built sockets receptacles for linking the Slam Hornet units in series apart from CSH118 Other common accessories Antistatic protective film for PC tube against chemical s...

Страница 7: ...5 ohm High voltage test electrical strength The purpose of this test is to measure leakage current trough insulation Vital test for revealing broken components or similar failures which can not be ide...

Страница 8: ...t category For explosion hazardous areas there are three equipment categories Category 1 product is suitable for use in Zones 0 1 and 2 20 21 and 22 Category 2 product is suitable for use in Zones 1 a...

Страница 9: ...ntioned in this instruction are Temperature Class T4 GASES Slam units with fluorescent tube and LED modules mentioned in this instruction are having maximum surface temperature of 90 C DUSTS 2 1 5 Env...

Страница 10: ...be used together with step down transformers Using Slam Hornet unit with transformers of 2 pole socket outlets without earthing bonding imposes certain extra requirements for the unit itself All the e...

Страница 11: ...king capacity of at least 1500 A Earth Leakage Circuit Breaker ELCB It is recommended to use a supply with 30 mA ELCB Please observe the type label for further data Luminaires for 110 VAC or 230 V sup...

Страница 12: ...is only for chaining Slam Hornet units 5 Fix them with accessories you have selected 6 Take the chain into Ex area Amount of lights which may be connected with each other depends on the supply voltage...

Страница 13: ...net control gear protects itself against excessive voltage drops numerous linking by switching itself off If too many units are connected to the chain some units of the chain will switch off You may s...

Страница 14: ...needed for measuring surface resistance of the PC tube 5 Maintenance instructions with exploded view diagram and spare parts list are available at your local distributor and the manufacturer Please wh...

Страница 15: ...Gas Atmospheres Please observe the requirements of the valid standards of the day Please study at least the following standards EN IEC 60079 14 Electrical installations in hazardous areas EN IEC 60079...

Страница 16: ...16 Helpdesk Under any doubt or question please contact your local distributor or the manufacturer Contact details Phone 358 20 734 3250 Fax 358 20 734 3299 Email info atexor com Web http www atexor c...

Отзывы: