ATESS NOVO EVA-11-PE Скачать руководство пользователя страница 1

ATESS NOVO EVA-11/22S-SE/PE

 

3-phase AC charger Quick installation guide

 + 

86 755 2998 8492

T

Shenzhen Atess Power Technology Co.,Ltd

3rd floor, building 9, Henglong industrial park, the fourth industrial zone of Shuitian community, 
Baoan district, Shenzhen, China

E

 

[email protected]

W

www.atesspower.com

Revised date:2022-5-26

Содержание NOVO EVA-11-PE

Страница 1: ...lation guide 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China E info atesspower com W www atesspower com Revised date 2022 5 26 ...

Страница 2: ...oduct description II Packaging list III Installation and wiring IV Parameter setting V Operation instruction and LCD description VI Firmware update VII Troubleshooting VIII Use excess solar power to charge your car IX Intelligent power modulation X Specification XI Annex I 1 3 4 8 18 22 26 34 37 40 41 This user manual is copyrighted by Shenzhen ATESS Power Technology Co ltd Hereinafter referred to...

Страница 3: ... AC input cables 9 Waterproof cable gland for communication wires Wiring definition in the side window 1 Terminal block for CT meter wiring The terminal definition is 485A 485B is RS485 terminal for meter connection Ia Ia Ib Ib Ic Ic is for CT connection 2 AC input terminals Terminal definition is L1 L2 L3 N PE 3 Peak Off Peak Charging Enable signal is eSense L N 1 2 3 4 5 8 9 6 7 485A B la la lb ...

Страница 4: ... fixing 4 3 8 User card 1 RFID function will be equipped with user card III Installation and wiring 3 1 1 Open the packaging you ll see a charge point a mounting bracket a user manual and a bag of mounting accessories There is also an RFID card if the charge point is RFID version For cabled version a cable hooker is also included inside 3 1 Mount on a wall 3 1 2 Remove the mounting bracket from th...

Страница 5: ...le and mounting accessories 3 2 2 The pole must be installed on a hard surface concrete surface is recommended it can also be mounted on a solid ground Drill hols according to the requirements marked on the illustration for fixing expansion bolts 3 2 3 Fix the pole onto the holes with expansion bolts The input cables shall go into the pole from the bottom middle area and come out of it from the ar...

Страница 6: ...lation and wiring is done connect the Charger to a computer and configure parameters via the web browser of the computer then the Charger can be ready for use IV Parameter setting 4 1 Set computer s IP The Charger s default IP address is 192 168 1 5 To access the parameter setting interface you ll need to first set the computer s IP to 192 168 1 x x can be any value between 1 and 255 except for 5 ...

Страница 7: ...browser on a computer It is suggested to use IE or Firefox other browser might have compatibility problem 4 2 Configure parameters 3 Right click on Local Area Connection and click on Properties 4 Select Internet Protocol Version 4 TCP IPv4 and click on Properties 5 Select Use the following IP address and enter the IP address Subnet Mask Default Gateway Click OK and close the Local Area Connection ...

Страница 8: ...this is the unique identification of the Charger If the charger is to be connected to ATESS back office server this ID must be set as the serial number on the nameplate of the Charger Otherwise the Charger cannot be registered on the server Fig 2 Please note After restoring the charger to factory setting you ll need to reset the charger ID same as serial number can be found on the nameplate sticke...

Страница 9: ...ication Key and Heartbeat Interval is used for testing and no need to reset Fig 7 8 Charging fee per unit of electricity Fig 8 9 PIN of the charger used to verify the PIN of user card To use a RFID card with the charger their PIN must be consistent If the user card has a different PIN then it cannot be used on this charger The default PIN setting of the charger is 242007 Fig 9 10 Peak time period ...

Страница 10: ...meters are used for power management setting Fig 19 23 Over temperature protection value not suggested to change 24 Charging allowed time Charging can only start within this time period This is used for off peak charging setting If you want to charge out of this period just press the forced on off button at the side of the charger Fig 20 Fig 21 25 DC residual current sampling value calibration Ent...

Страница 11: ...Fig 28 V Operation instruction and LCD description 5 1 Charging mode and Operation APP RFID mode Initiate or cease charging by scanning QR code using APP or by swiping RFID card You can also use APP for reservation and payment provided that the back office server supports such functions APP RFID mode operation process flow If you are using the ATESS APP Charging can be started stopped by pressing ...

Страница 12: ... Interface of standby status Charging mode is displayed at the bottom centre of the screen Interface of user card information Displayed for user to check card ID and balance when swiping RFID card while EV is not connected Interface of charging status Displayed when the charging is being carried out There is charging time consumed electricity charging cost on it as well as real time charging volta...

Страница 13: ...ng user ID and remaining time to reserved time VI Firmware update There are 2 ways to update firmware for EV charger 1 Update by SD card 2 Update on parameter setting page 6 1 Update by SD card 1 Prepare a microSD card with capacity not greater than 4G Format the SD card using FAT32 The firmware file must be named as App bin 2 In the root directory of the SD card rename the firmware file as App bi...

Страница 14: ...ger to computer via a network cable the computer s IP must be within the 192 168 1 x segment x is any value between 1 and 255 except 5 Open the web browser type in the charger s default IP of http 192 168 1 5 8080 and click enter then you can check the firmware version on the appeared parameter setting page 6 2 Update on parameter setting page Using this method for update doesn t require any speci...

Страница 15: ...ubleshooting 7 1 Troubleshoot by LED behavior or LCD display If fault occurs users can check the fault information on the LCD or by the number of blinks of the LED indicator light Each fault is indicated with a sequence of different numbers of LCD blinking A pause of 3 seconds between each sequence indicates the beginning or end of a sequence If multiple faults happen at the same time each sequenc...

Страница 16: ...C Signal strength on mobile b Please check and input the correct WiFi SSID and password to retry If you check the WiFi setting on the APP please turn off and back on the charger and connect your mobile to the WiFi emitted by the charger for checking and setting c Check if there is access control in the router e g MAC filtering port blocking etc To verify this you can use your mobile phone to creat...

Страница 17: ...rnet 2 Click Change adapter settings 29 30 d 1 Some routers have 2 WiFi one is 2 4GHz the other is 5GHz Most homes just use the 5GHz WiFi as their default WiFi But the charger can only connect to the 2 4GHz WiFi So if the charger can connect to your mobile phone hotspot but cannot connect to the home WiFi Please check with the home owner or check on their router to see if you are using the 5GHz Wi...

Страница 18: ... if you have input the complete content which is http 192 168 1 5 8080 in the address field do not leave out the http or the 8080 e Sometimes you may need to restart the charger to access its parameter setting page f If you have changed the charger s IP to other value and cannot remember you can restore the charger to factory setting by long press the reset button Then you can access it using http...

Страница 19: ...r the real time power import and export a CT or meter is needed for this function to work properly If CT is used the wiring will be as below FAST Mode Charge at the rated power the car can be fully charged in the shortest time at this mode ECO Mode 1 solar function set the power p range Pe stands for rated power P1 stands for Power Transferred to Power Grid by Photovoltaic 1 The power of three pha...

Страница 20: ...nd the following parameters Solar Mode FAST ECO or ECO 3 Select CT or meter as sampling device of this solar charge function Scroll down to find the option External Power Sampling Wiring 0 Inner CT 1 PowerMeter If CT is used please set it to 0 if meter will be used please set it to 1 4 If you choose the PowerMeter Plesae change PowerMeter Addr to the address shown on the meter Black Black Black Bl...

Страница 21: ...mum allowable power 9 1 Similar with the solar charge function a CT or meter is needed to detect the power import If a CT is used please wire it as below 37 38 9 2 If a meter is used the wiring will be as the following 9 3 Parameter configuration for this function 1 Connect the charge point to a laptop with a network cable access the parameter setting page on the web browser of the laptop 2 Scroll...

Страница 22: ... the max power import to 13kW or 14kW X Specification Dimension mm Weight kg Display Casing Material Input Voltage Output Voltage IP Protection degree Working environment temperature Relative humidity Altitude Frequency Communication Charging mode Standby power Standard Mounting Certificate Protection features Overvoltage Undervoltage Overcurrent Shortcircuit Leakage protection Over temperature Li...

Страница 23: ...ontact Company Name Shenzhen Atess Power Technology Co Ltd Address 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen China Website www atesspower com Service line 8675529988492 E mail info atesspower com ...