ATESS EVC-AC22S/DC60D Скачать руководство пользователя страница 1

ATESS EVC-AC44S/DC60D 104kW

AC/DC charging equipment user manual 

 + 

86 755 2998 8492

T

Shenzhen Atess Power Technology Co.,Ltd

3rd floor, building 9, Henglong industrial park, the fourth industrial zone of Shuitian community, 

Baoan district, Shenzhen, China

E

 

[email protected]

W

www.atesspower.com

Содержание EVC-AC22S/DC60D

Страница 1: ...uipment user manual 86 755 2998 8492 T Shenzhen Atess Power Technology Co Ltd 3rd floor building 9 Henglong industrial park the fourth industrial zone of Shuitian community Baoan district Shenzhen Chi...

Страница 2: ...y for electric vehicles which has a friendly man machine interface and integrates corresponding functions of control billing communication and security protection The charging equipment uses OCPP 1 6J...

Страница 3: ...stem Parameters 4 2 Network parameters 4 3 Protection parameters V Operation instruction and LCD introduction 5 1 Charging mode and operation 5 2 LCD interface introduction 5 3 Appendix Fault code VI...

Страница 4: ...the surge protection circuit and replace the lightning protection module The red circle in the figure is the lightning protection status indicator When the indication window indicates green the lightn...

Страница 5: ...area to avoid flooding water 2 The foundation pile is to be made of reinforced concrete which requires for a minimum allowable bearing pressure of 1000kg squire meters for the base 3 Construct main gr...

Страница 6: ...and phase sequence The earth cable shall be connected to the grounding bar of the charger Wiring illustration is shown in elow Please notice For safety the charger must be grounded securely Connect t...

Страница 7: ...charge mode payment is not needed 2 is APP or RFID mode No Parameters Function description 8 9 10 Time set Language set Meter address DC meter s modbus address already preset in factory it is not allo...

Страница 8: ...rvoltage value DC output overcurrent value AC input overvoltage value AC input undervoltage value AC input overcurrent value DC output limit power Charger over temperature value Charger derate tempera...

Страница 9: ...payment provided that the back office server supports such function 4 5 2 3 1 APP RFID mode operation process flow Plug Charge Charging will start automatically after EV plugged in If you want to stop...

Страница 10: ...when entering each parameter setting page Password window Before entering numeric please first press the text display field to move the cursor there then you can type in the 4 digit password A wrong p...

Страница 11: ...tactor sticking fault AC Input Overvoltage AC Input Undervoltage BMS communication fault VI Specification Model EVC AC44S DC60D Dimension mm 1883 600 743 W H D Weight kg 250KG Display LCD Casing mater...

Страница 12: ...C output Over temperature protection Short circuit protection Emergency stop protection Lightning protection Leakage protection 20 50 Ip54 95 2000m derate for higher than 2000m Forced air cooling Ethe...

Страница 13: ...etc 4 Failure or damage caused by the installation repair modification or disassembly byunauthorized service personnel 5 Failure or damage caused by using ATESS Power Technology s genuine spare parts...

Отзывы: