7 / 74
FG_F6_MODBUS_EN_01 / 2020-06-17
Hardware installation
HARDWARE CONFIGURATION
Connect your ATEQ equipment to the Modbus RTU network using its Modbus RTU connectors and
compatible cables.
Your device has one Modbus RTU connector.
For more information on your ATEQ equipment, refer to the Quick Start Manual.
Modbus RTU connector
–
9 pins male connector
Pin number
Signal
1
-
2
RXD (receive data)
3
TXD (transmit data)
4
-
5
Ground
6
-
7
RTS (request to send)
8
CTS (clear to send)
9
-
Architecture of the Modbus RTU network
The network is built on the basis of a cable composed of two pairs of entwined and shielded wires.
One pair is for the signals and the other is for the ground.