VM6404H User Manual
78
EDID Mode Command
Extended Display Identification Data (EDID) is a data that contains a display's
basic information and is used to communicate with the video source.
The formula for the EDID command is as follows:
C C [Enter]
1. For example, to use the Port1 EDID mode, type:
edid port1 [enter]
The following tables show the possible values for the
EDID
command:
Note:
Each command string can be separated with a space.
The following table lists the available EDID commands:
Command
Description
edid
EDID Mode command
Control
Description
port1
Implement the EDID of the connected
display to Port 1, and pass it to the
video source.
remix
Implement the EDID of each
connected display according to its
connection when the VM6404H is first
powered on, or immediately after
selecting the Remix option.
default
Implements ATEN’s default EDID.
(default)
custom
Implements the customized mode as
set in the EDID system settings.
(See
Customized EDID Settings
,
page 64)
Command
Control
Enter
Description
edid
port1
[Enter]
The EDID from Port 1 is passed to the video
source.
edid
remix
[Enter]
The VM6404H implements the EDID of each
connected display according to its connection
when it is first powered on, or immediately
after selecting the Remix option.
edid
default
[Enter]
ATEN’s default EDID is passed to the video
source.
edit
custom
[Enter]
Implements the customized mode.
Содержание VM6404H
Страница 1: ...4 x 4 4K HDMI Matrix Switch with Scaler VM6404H User Manual www aten com ...
Страница 12: ...VM6404H User Manual xii This Page Intentionally Left Blank ...
Страница 20: ...VM6404H User Manual 8 This Page Intentionally Left Blank ...
Страница 24: ...VM6404H User Manual 12 Installation Diagram 5 6 3 2 4 7 1 ...