Modular Matrix Solution User Manual
120
EDID Mode Command
Extended Display Identification Data (EDID) is a data that contains a display's
basic information and is used to communicate with the video source. The EDID
Mode commands allow you to change the EDID setting.
The formula for the EDID command is as follows:
C A C [Enter]
1. For example, for port 06 to use the remix EDID mode, type:
edid a06 remix [Enter]
1. For example, to use Port1 EDID mode for all devices, type:
2.
edid a* port1 [Enter]
The following tables show the possible values for the
EDID
command:
Command
Description
edid
EDID command
Address
Description
a
Device address command
(RS-422 and RS-485 only)
Number
Description
zz
Device address
zz: 01~16 (default is 01)
(RS-422 and RS-485 only)
*
All devices
Control
Description
port1
Implement the EDID of the connected
display to Port 1, and pass it to the
video source.
remix
Implement the EDID of each
connected display according to its
connection when the VM1600 is first
powered on, or immediately after
selecting the Remix option.
default
Implements ATEN’s default EDID.
(default)
custom
Implements the customized mode as
set in the EDID system settings.
(See