5. RS-232 Commands
45
Save/Load Profile Commands
The formulas for Save/Load Profile commands are as follows:
1. C P A C [Enter]
For example, to save the current connection configuration to profile 12 on
device 01, type the following:
profile f 12 a01 save [Enter]
2. C P A C [Enter]
For example, to load profile 12 on device 01, type the following:
profile f 12 a01 load [Enter]
The following tables show the possiblee values for commands:
Command
Description
profile
Save / Load profile
Profile
Description
f
Profile
Profile Number
Description
yy
00-15 (default is 00)
Device
Number
Description
zz
00-15 (default is 00)
*
All devices
Address
Description
a
Device address
Control
Description
save
Save the current connection
configuration
load
Load a saved profile