Chapter 5. RS-232 Commands
73
EDID Command
Extended Display Identification Data (EDID) is a data that contains a display's
basic information and is used to communicate with the video source.
The formula for the EDID command is as follows:
C Input + C [Enter]
1. For example, to apply the EDID setting of the display connected to output
port1, and pass it to the video source connected to input port2, type:
edid i02 port1 [Enter]
The following tables show the possible values for the
EDID
command:
Note:
Each command string should be separated with a space.
Command
Description
edid
EDID command
Input Command
Description
i
Input port
Port number
Description
xx
VM0404HB: 01~04
VM0808HB: 01~08
*
All input ports
Control
Description
portyy
Implement the EDID of the connected
display to output port yy, and pass it to the
video source.
(yy: 01~04 or 01~08)
remix
Implement the EDID of all connected
displays. The VM0404HB / VM0808HB
uses the best resolution for all displays.
defaultyy
Implements one of the 18 ATEN default
EDID configuration.
(yy: 00~17, default is 00)