Страница 1: ...User Manual ATEN VanCryst VK Series Con gurator ATEN Control System...

Страница 2: ...ration of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The device complies with P...

Страница 3: ...ATEN Control System User Manual iii Industry Canada Statement This Class A digital apparatus complies with Canadian ICES 003 RoHS This product is RoHS compliant...

Страница 4: ...8 Button Keypad US 1 Gang VK112EU 12 Button Keypad EU 2 Gang ATEN Touch Panel VK330 10 1 Touch Panel ATEN Expansion Box VK224 4 Port Serial Expansion VK236 6 Port IR Serial Expansion Box VK248 8 Chann...

Страница 5: ...rol System Chapter 4 ATEN Configurator VK6000 Provides a complete description of the ATEN Configurator VK6000 software and its configuration operation features for managing the ATEN Control Sys tem Ch...

Страница 6: ...information Terminology Description ATEN Controller controller ATEN Controller or controller refers to all models of ATEN Control Box VK1100 VK1200 and VK2100 VK2200 and ATEN Control Pad VK0100 and V...

Страница 7: ...ceplate 1 user instructions VK0200 1 VK0200 12 Button Control Pad 1 button pack 6 terminal blocks 1 faceplate 1 user instructions VK1100 1 VK1100 Compact Control Box 4 terminal blocks 1 power cord 1 u...

Страница 8: ...cs 1 user instructions VK112EU 1 VK112EU 12 Button Keypad 1 button pack 1 terminal block 1 faceplate 1 user instructions VK108US 1 VK108US 8 Button Keypad 1 button pack 1 terminal block 1 faceplate 1...

Страница 9: ...ion Box 1 mounting kit 9 terminal blocks 1 user instructions VK330 1 VK330 10 1 Touch Panel 1 user instructions Note Read this manual thoroughly and follow the installation and operation procedures ca...

Страница 10: ...s no representations or warranties either expressed or implied with respect to the contents hereof and specifically disclaims any warranties as to merchantability or fitness for any particular purpose...

Страница 11: ...uthorized modifications to this device It is the responsibility of the user to correct such interference The manufacturer is not responsible for any damage incurred in the operation of this system if...

Страница 12: ...VK330 ix Product Information x User Information x Online Registration x Telephone Support x User Notice x Contents xii 1 Introduction Overview 1 Benefits 3 Intelligent Control 3 Optimized Performance...

Страница 13: ...23 12 V DC Power Output 29 Relay 33 IR Serial 34 One IR Transmitter 35 Two IR Transmitters 35 Digital I O 36 RS 232 3 Pin 38 RS 232 422 485 DB 9 39 Ethernet Control LAN 41 ATEN Control Pad 42 Panel C...

Страница 14: ...80 Working as a DHCP Server 80 Connections 81 Schedule 82 Security 83 4 ATEN Configurator VK6000 Overview 85 Installation 85 Getting Started Tasks 88 Main Screen 90 Overview 90 Menu Bar 91 Creating Pr...

Страница 15: ...Images 138 Layering Images 139 Videos 140 Dial Kit 144 Frame Line 146 Object Properties for ATEN Keypad Control Pad 147 Button Slider Bar Dial Kit Actions 150 Understanding Button Slider Bar Dial Kit...

Страница 16: ...d Monitoring and Control via Unizon 206 Overview 206 Unizon 206 Monitor ATEN controller managed Devices via Unizon 206 Control ATEN controller managed Devices via Unizon 206 Enabling Monitoring and Co...

Страница 17: ...your mobile device uses a supported version of the mobile operating system listed below before installing the app 259 Installing the App 259 Button Sounds 259 The ATEN Control System App 260 Demo Sta...

Страница 18: ...tions 296 CAD and Panel Cutout Diagrams 297 VK0100 297 VK0200 301 VK108US 305 VK112EU 309 Datapoint Types 313 ATEN Control Box Reset Button 316 Windows OS Button Limitation 317 Technical Support 318 I...

Страница 19: ...ices remotely whenever and however you like ATEN Control Box Control Pad can be easily deployed into an existing installation and integrate seamlessly with ATEN VanCryst pro AV products and nearly any...

Страница 20: ...rfect solution for any meeting rooms conferences boardrooms classrooms and any other room setting that requires a centralized mobile control of a variety of hardware devices through streamlined Ethern...

Страница 21: ...for remote control access Through an intuitive GUI the process for setting up the controls for every room is simple and customizable which is fulfilled via straightforward predefined commands and mac...

Страница 22: ...of scenarios effortlessly On the Go Control Intuitive system control can start from one room and scale up to multiple rooms both within the same area and even across regions Different rooms can be eff...

Страница 23: ...nagement systems Telnet TCP UDP ONVIF PJLink HTTP and HTTPS compliant Supports project file backup Supports up to 8 ATEN Keypads Web GUI for easy system configuration 2 free licenses for mobile contro...

Страница 24: ...buttons Customizable button text engraving service System LED indicators for quick connection status check Dual color LEDs for clear indication in dark environments Redundant power supplies DC power a...

Страница 25: ...vent monitoring to automatically trigger the next actions Test tool to verify commands in action before uploading the Viewer to the ATEN controller Simulator to simulate and review the customized GUI...

Страница 26: ...n Scalability an ATEN controller can connect up to 8 Keypads Versatile modes support flexible behavior settings for each button Intuitive Web GUI for easy configuration Redundant power supplies DC pow...

Страница 27: ...ntrolled PJLink Telnet ONVIF TCP UDP HTTP or HTTPS devices KNX interface IP devices Cables One Cat 5e 6 Ethernet cable for connecting to the local area network Optional Standard straight through cable...

Страница 28: ...or more information visit the ATEN website Contact your ATEN dealer to purchase these accessories Model Description 2XRT 0004G Full Range IR Emitter 1 8 m 2X 031G Single Rack Mount Kit for VK1100 2X 0...

Страница 29: ...ortant safety information regarding the placement of this device is provided on Safety Instructions page 279 Please review it before proceeding 2 Make sure that the power to all devices connected to t...

Страница 30: ...the LED lights orange please unplug any of the connected devices to keep its total output under 12 24 W 7 IR receiver LED Passes the functions of a remote control to the Control Box in learning mode...

Страница 31: ...Chapter 2 Hardware Setup and Panel Oper 13 11 controller ID switch Used to set an ID for the Control Box No Component Description...

Страница 32: ...hannels Four channels normally open isolated relays with a contact rating of 24 V DC 2 A max 6 IR serial ports 4 2 IR ports that can also be configured as RS 232 TX ports pin1 Signal pin2 Ground 7 I O...

Страница 33: ...32 RS 422 or RS 485 connection is defined by pin For pin assignments see page 39 10 Ethernet port Connects the unit to a network If no IP address is assigned by a DHCP server within 30 seconds the bel...

Страница 34: ...window should be kept under 10 cm with a direct line of sight The LED blinks green to indicate the unit is receiving signals from an IR remote control The LED lights green to indicate entering learnin...

Страница 35: ...the unit is turned on No Component Description 1 power socket Plugs in the power cord from an AC power source 2 power switch Powers the unit on or off 3 12 V DC output ports 1 4 DC output port s provi...

Страница 36: ...2 Ground 7 RS 232 422 485 serial ports 1 2 5 pin RS 232 422 485 serial ports by pin assignment 8 RS 232 serial ports 1 6 3 pin RS 232 serial ports with Tx Rx and GND 9 Control LAN Connects the unit to...

Страница 37: ...onto a 19 1U system rack The following diagrams are exemplified using VK2100 Using the rack mount kit attach the 2 mounting brackets onto the sides of the unit with the 6 screws included 2 Align the m...

Страница 38: ...U system rack 1 Remove the 2 screws from the bottom and 1 screw from each side of the unit 2 Using the 2 bottom screws from step 1 and 2 M3x6 screws from the rack mount kit secure the mounting bracket...

Страница 39: ...the 2X 049G or 2X 021G rack mount kit for single or dual rack mount respectively Single Rack Mount 1 Using the rack mount kit attach the 2 mounting brackets onto the sides of the unit with the 4 screw...

Страница 40: ...2 Use 4 of the screws from step 2 to secure the two VK1200 units together with the link bracket Then install the left and right mounting brackets onto the sides of the units using 2 of the M3x5 and M3...

Страница 41: ...VK2200 use another Cat 5e 6 cable to connect its LAN port to the corporate network 5 Use the DC output terminals to wire 12 V DC power connections using the instructions on page 31 6 Use the relay ter...

Страница 42: ...interface to the network where the Control Box is installed 2 To check if the KNX functions are supported by the Control Box see Specifications page 282 13 For VK1100 VK2100 use the controller ID swi...

Страница 43: ...l Relay Digital I O Controller ID Switch Ground Power Input RS 232 RS 232 422 485 Connect to network via Cat 5e cable Connect to RS 232 serial devices Connect to provide 12 V DC power supply Connect t...

Страница 44: ...elay Digital I O Ground Power Input RS 232 RS 232 422 485 Connect to secured subnetwork Connect to RS 232 serial devices Connect to provide 12 V DC power supply Connect to IR or RS 232 devices Conect...

Страница 45: ...via Cat 5e cable Power Input Power Outlet Relay Connect to switch or motor devices 12 V DC Power Output Connect to provide 12 V DC power supply IR Serial Connect to IR or RS 232 devices Connect to RS...

Страница 46: ...ower Output Connect to provide 12 V DC power supply Relay Connect to switch or motor devices IR Serial Connect to IR or RS 232 devices Connect to RS232 422 485 devices RS 232 422 485 7 6 4 11 5 2 1 Di...

Страница 47: ...turned off To return power to the ports power off the Control Box unplug all hardware connected to the 12 V DC output ports power on the Control Box and then plug in the hardware devices one at a tim...

Страница 48: ...User Manual 30 Relay Power Supply Connects to Provides 12 V DC power for the relay loop Power Supply 12 V DC 1 A 2 A Max 12 V DC Output Ports Switch Screen Projector Lift Lighting Motorized Equipment...

Страница 49: ...Oper 31 Digital Output Power Supply inapplicable to VK1100 Power Supply 12 V DC 1 A 2 A Max Connects to Switch Screen Projector Lift Lighting and Equipment Control 12 V DC Output Ports Provides 12 V D...

Страница 50: ...igital Output Dual Power Supply VK2100 VK2200 only Power Supply 12 V DC 1 A 2 A Max 12 V DC Output Ports Provides 12 V DC power for the digital output loop Provides connection to digital output 2 Prov...

Страница 51: ...ing isolated relays VK1100 VK1200 VK2100 VK2200 Number of Channels 4 8 Contact Rating 24 V DC 2 A Default Status Normally Open Normally Open Closed NO Isolated Relays 24 V DC 2 A Max Switch Screen Pro...

Страница 52: ...200 VK2100 VK2200 2 Pin IR Serial 2 4 8 IR Carrier Frequency 10 455 kHz Default Level Low Serial RS 232 Baud rate 300 115200 default 9600 Data bit 7 8 default Stop bit 1 default 2 Parity None default...

Страница 53: ...nd terminals to a set of serial TX and ground terminals of the Control Box Then configure the same serial port settings on both the Control Box and the connecting serial device allowing them to commun...

Страница 54: ...iding voltage signals 1 24 V to the ATEN Control Box to trigger certain events and or functions when the voltage signals are above or below the defined threshold VK1200 VK2200 VK2100 Number of Channel...

Страница 55: ...hardware devices such as electric screens projector lifts and other motorized equipment which must be connected using a relay module as shown below Digital Output Switch Screen Projector Lift Lightin...

Страница 56: ...RX and ground GND terminals must be wired on both the ATEN Control System and the device connecting VK1200 VK2100 VK2200 Number of Channels 1 2 6 Baud rate 300 115200 default 9600 Data bit 7 8 defaul...

Страница 57: ...232 422 485 5 Pin The ATEN Control System provides the following RS 232 422 485 ports RS 232 RS 422 RS 485 pin 2 RX pin 1 RX pin 3 D pin 3 TX pin 2 RX pin 4 D pin 5 GND pin 3 TX pin 7 RTS pin 4 TX pin...

Страница 58: ...gurable by pin assignments for controlling and receiving status messages from them Stop bit 1 default 2 Parity None default Even Odd VK1200 VK2200 Projector Matrix Switch Camera etc Connects to Config...

Страница 59: ...device in a network Ethernet Control LAN SELECT PDU CURRENT OUTLET CURRENT IP ADDRESS SENSOR 1 SENSOR 2 OUTLET STATUS ONVIF TCP PJLink Telnet Telnet The RJ 45 port is used to connect and access TCP UD...

Страница 60: ...ATEN Control System User Manual 42 ATEN Control Pad Panel Components VK0100 VK0200 2 3 4 9 8 7 5 1 6 Front View Rear View Side View 9 8 1 2 3 5 4 6 7 Front View Rear View Side View...

Страница 61: ...ad is actively transmitting and receiving data 3 reset button To clear all the configurations except the network settings press and hold the reset button for 8 seconds To reset the network settings pr...

Страница 62: ...Pad is powered on and the button is currently off a button LED lights white The Control Pad is powered on and the button is currently on a button LED blinks orange and white repeatedly The function a...

Страница 63: ...Projector Video Switch Projector Projector Lift Ethernet Cable Camera Network Lighting Control Conference System Door Sensor Dry Contact Device PoE Switch Relay RS 232 DI 2 2 2 3 Relay DI Screen Proj...

Страница 64: ...ion Boxes 3 To use PoE connect the Control Pad to a PoE switch via an Ethernet cable For details see Ethernet page 53 4 If you do not have power sourcing equipment for PoE contact your local sales rep...

Страница 65: ...ontrollers using shared IDs reconfigure the connection mode For details see Controller Properties page 106 6 Power on all the devices The button LEDs light orange 7 Assemble the button caps onto the C...

Страница 66: ...TEN Control System User Manual 48 8 Mount the Control Pad to the wall a Secure the Control Pad to the wall with self prepared screws b Install the supplied faceplate to the Control Pad VK0100 VK0200 E...

Страница 67: ...Chapter 2 Hardware Setup and Panel Oper 49 VK0200 MK...

Страница 68: ...d devices For bidirectional RS 232 control the transmit receive and ground pins must be wired on both the Control Pad and hardware device Each hardware device requires different wiring Please consult...

Страница 69: ...hardware devices such as electric screens projector lifts and other motorized equipment Each relay is normally open by default Normally Open Closed Normally Open Isolated Relays Contact Rating 24VDC...

Страница 70: ...rough the Control Pad Digital Input VDC Digital input 5VDC hardware devices temperature current and monitor sensors provide voltage signals between 1 and 5 A digital input port detects if a voltage is...

Страница 71: ...own below Ethernet SELECT PDU CURRENT OUTLET CURRENT IP ADDRESS SENSOR 1 SENSOR 2 OUTLET STATUS ONVIF TCP PJLink Telnet Telnet The RJ 45 port is used to connect and access TCP UDP PJLink ONVIF HTTP HT...

Страница 72: ...locations across a network The diagram below provides a setup example using the VK224 a 4 Port Serial Expansion Box Note To add and configure ATEN Expansion Boxes see Left Sidebar page 100 and Expans...

Страница 73: ...follows Note The following Keypad models are available You can have your Keypad buttons customized with text engraving To make the order go the this link https www aten com ext_data global_en VK_Keyp...

Страница 74: ...Indicate function and Keypad statuses For detailed information see LED Indications page 57 3 system LED indicators LAN lights green to indicate that the Keypad is connected to LAN Link lights green t...

Страница 75: ...n LED Activity Control Pad Status a button LED lights orange The Keypad is powered on and the button is currently off lights white The Keypad is powered on and the button is currently on blinks orange...

Страница 76: ...ATEN Control System User Manual 58 Layout Examples VK108US VK112EU...

Страница 77: ...Keypad follow the steps below 1 Choose a location free of interference and prepare the installation site You can install the Keypad to a wall box or directly into the chosen surface Using a wall box...

Страница 78: ...uses Note One ATEN Control Box can work with up to 8 Keypads 3 Supply the Keypad with power and network connectivity using one of the following methods The LAN LED light green to indicate that the Key...

Страница 79: ...t with its assigned Control Box The Keypad adopts the default IP address 192 168 0 60 if the network switch does not support DHCP To configure the IP address log in the web interface using the default...

Страница 80: ...n caps place your fingers on the top of button caps and then press downwards as illustrated below Pressing upwards from the bottom may cause damages to the button caps c Attach the faceplate to the Ke...

Страница 81: ...ghts on when the touch panel is powered on 3 function button Press the Function button to show the settings page 4 brightness up down Press to adjust the display brightness volume up down Press to adj...

Страница 82: ...er to the diagram below 7 USB type A port Use this port to update the ATEN Control System app installed in the Touch Panel For details see Updating Control System App page 67 8 Micro USB port Use this...

Страница 83: ...ount accessory VK302 follow the steps and refer to the diagrams below 1 Secure the wall plate to the wall using the wall anchors and screws 2 Secure the panel plate to the VK330 using the M4 screws 3...

Страница 84: ...ils on using the Control System app see The ATEN Control System App page 260 To configure system settings of the Touch Panel press the Function button on the device open the system settings page Chang...

Страница 85: ...orage tap the USB device you inserted 5 Locate and tap the app file apk to start the update Upgrading Firmware for ATEN Touch Panel To upgrade the ATEN Touch Panel firmware on your ATEN Touch Panel fo...

Страница 86: ...ATEN Control System User Manual 68 This Page Intentionally Left Blank...

Страница 87: ...y enable monitors and upgrade the firmware Determining the IP Address DHCP When connected to a DHCP network the ATEN controller is automatically assigned with an IP address upon startup To determine t...

Страница 88: ...P Installer Using a Windows PC download the IP Installer zip file in Support and Downloads from the ATEN controller s product web page Then extract and execute IPInstaller exe A window similar to the...

Страница 89: ...IP address of the controller into the address bar of any browser If a Security Alert dialog box appears accept the certificate it can be trusted The Welcome screen appears The default access key is pa...

Страница 90: ...hen you successfully log in to the Control Box The Dashboard gives a quick view of each setting and provides a link to each page Click Edit to configure the settings The top bar provides two options C...

Страница 91: ...tab contains network information and the time and firmware upgrade settings Setting Descriptions Controller Info Provides network and identification information pertaining to the controller Device Nam...

Страница 92: ...Server IP Select this option to use a private NTP server if the controller is installed in a closed network Alternate Customer Server IP Select this option to set up a substitute server if the contro...

Страница 93: ...enses each controller supports To purchase additional copies of license contact your local sales representative You can use the Licenses tab to Find out the total number of licenses the number of lice...

Страница 94: ...he controller to upload Viewers as well as Space Used The amount of space currently being used to store Viewers uploaded to the controller Space Available The amount of space currently available to st...

Страница 95: ...he following settings are available Current Access Key New Access Key Confirm Access Key Use these three fields to set or change the access key The default access key is password IMPORTANT You will be...

Страница 96: ...cters uppercase and lowercase letters numbers and underscore Max number of days 999 days 3 Type the activation key again to confirm 4 Click Save The limit is immediately applied For example Note Keep...

Страница 97: ...onfigured for Flags and digital input devices in ATEN Configurator Check the Show on dashboard box to show the Monitor settings on the Dashboard Click the slide bar next to the monitor you want to ena...

Страница 98: ...te as a DHCP server for automated assigning dynamic IP addresses to all of the LAN devices managed via its Control LAN To do this follow the steps below 1 From the Get IP Address drop down list select...

Страница 99: ...Chapter 3 Web Based Configuration and 81 Connections The Connections tab allows you to view the connection statuses and IP addresses of licensed devices ATEN Keypads and ATEN Expansion Boxes...

Страница 100: ...dule tab lists scheduled events predefined using the ATEN Configurator You can use this tab to do the following Enable or disable scheduled events Enable or disable scheduled days For details on setti...

Страница 101: ...yption on the controller purchase and obtain an SSL certificate from a trusted certifying authority and click Upload to apply the certificate TLS Support Each ATEN controller supports TLS 1 0 1 1 and...

Страница 102: ...ATEN Control System User Manual 84 This Page Intentionally Left Blank...

Страница 103: ...ices and ATEN Keypads Installation To install the ATEN Configurator software do the following 1 Download ATEN Configurator a Visit the ATEN download page http www aten com global en support and downlo...

Страница 104: ...ual 86 3 Click Next This screen appears 4 If you agree with the License Agreement select I accept the terms of the license agreement and click Next Click Print to print the Software End User License A...

Страница 105: ...tor VK6000 87 5 To change the destination location click Change Click Next to proceed using the default location This screen appears 6 Click Install When the process is complete a confirmation message...

Страница 106: ...N controller Click Add Controller if you have more than one controller in the environment For more details see The menu bar contains the Configurator s main functions arranged by category Refer to the...

Страница 107: ...carry out specified actions Optional Add additional conditions and actions to buttons using Flags For details see Flag page 176 Optional Create a sequence of actions for a button by creating a Macro F...

Страница 108: ...b and the Library icon Each tab relates to a step required to set up the project Each step and the Library can be selected by clicking on the bar 3 Interactive Display Panel This is the main work area...

Страница 109: ...ose Closes the current project and returns to the Project tab Save Select to save changes to the current project Save as Use this option to save the project as a different name Export Viewer to USB No...

Страница 110: ...n Viewer Select All Deselect All Use either option to select or unselect all objects when editing a viewer page in Create Design Viewer Preferences Display Language Use to select the language for the...

Страница 111: ...gn to Grid is not selected objects can be placed anywhere on the page Show Grid Select to display the grid dots on the page Use with the Align to Grid option to set objects in perfect alignment on the...

Страница 112: ...can be used for dialing a meeting Group Group Select multiple objects and use Group to lock them together Objects in the group will move together as one Radio Group Select multiple buttons and use Rad...

Страница 113: ...Same Size Width Resizes two or more selected objects to the same width of the object that is selected last Height Resizes two or more selected objects to the same height of the object that is selected...

Страница 114: ...llows you to tryout the interface as it would work on a mobile device but without actually controlling devices Use the mouse to click through the page links SSH Client This runs the SSH Client softwar...

Страница 115: ...or most installations only one project is required Add Controller Click to add controllers to the project The number added should match the number of controllers installed A project can have up to 16...

Страница 116: ...rdware in that room appears This link between the controller devices and room is how the Viewer knows which devices to control Name Enter the client name associated with the project Address Enter the...

Страница 117: ...ed by Unizon Clickon a controller expansion box or Room in the left sidebar to display the ports Each port needs to be configured according to the hardware device connected to it For details see Left...

Страница 118: ...This links the controller in the software to the physical device being installed Right click a controller to Add Room or Delete Controller Room Each room is associated with a controller and a Viewer...

Страница 119: ...ed to it Control Description Type Lists the ports of the controller Device Lists the device name entered in Properties Mode Lists the port s communication mode Click an arrow to select options Serial...

Страница 120: ...his feature to work For an overview of how to set up the function see Centralized Monitoring and Control via Unizon page 206 Add More Devices RS422 RS485 LAN and IR ports can cascade additional device...

Страница 121: ...nt use one of the following methods Via ATEN Device Library or My Library 1 In the Device Configuration list click a port where you have physically installed a device 2 Click library In the pop up win...

Страница 122: ...hod to automatically bring in default settings for the selected device a Click the arrow button and select Add device from the Library to open the Library b Click the drop down list to select ATEN Dev...

Страница 123: ...ls see Editing Adding a New Device page 226 Adding KNX compliant Devices to ATEN Configurator 1 Click File and then Import ETS Project The configurations for your KNX devices appear in the Controller...

Страница 124: ...troller ID Switch Identify ATEN Expansion Box and Keypad by IP Address Enable this function for the controller to connect to ATEN Expansion Box or Keypad by identifying their IP addresses Use this fun...

Страница 125: ...ress function the Properties panel For example if you have 17 controllers set up under the same subnet with controller 1 and 17 using ID01 enable the function for both of these controllers Specify the...

Страница 126: ...ation list to configure or view the following properties Name Displays the device model Expander ID Select the expander ID Make sure the ID matches the one set physically on the Expansion Box IPAddres...

Страница 127: ...he device Use the drop down menu to select a different firmware version Click the menu box next to the version number to open a PDF with the version history The version history and different versions...

Страница 128: ...is value to identify the end of a message Keep Connection Alive The controller sends a command to the serial device to maintain the connection and avoid timeout issues Command Type a command to be sen...

Страница 129: ...ected device Version Shows the firmware version selected for the device Use the drop down menu to select a different firmware version Click the menu box next to the version number to open a PDF with t...

Страница 130: ...selected device Model Displays the model of the selected device Version Shows the firmware version selected for the device Use the drop down menu to select a different firmware version Click the menu...

Страница 131: ...e Use the drop down menu to select a different firmware version Click the menu box next to the version number to open a PDF with the version history The version history and different versions for a de...

Страница 132: ...y Interval setting Delay Interval Sets a time delay for each command before they are sent to the device Delay after Login for telnet only Sets a delay to allow a connection to be established before th...

Страница 133: ...shown below to configure controller ports according to the connected hardware devices The Device Library provides an extensive database of hardware devices that can be double clicked or drag and drop...

Страница 134: ...or double click a port on the Device Configuration page to open the ATEN Device Library Add a device by clicking Add to Project or by drag drop To search for a device type keywords into the box and c...

Страница 135: ...ure the following Viewers Parameters of the managed devices that are monitored and or controlled by Unizon For more information see Select Viewer The Select Viewer section allows you to select a Viewe...

Страница 136: ...utton is used to test a Viewer s interface after it has been created The simulator allows you to tryout the interface as it would work on a mobile device but without actually controlling devices Use t...

Страница 137: ...a new Viewer Pages Each Viewer lists the Home Page with each Viewer Page created for the Viewer under it Clicking a Home or Viewer Page on the sidebar opens a new tab where the page can be edited Righ...

Страница 138: ...ypads ATEN Control Pads or ATEN Touch Panels to centrally control devices and equipment To add a Viewer and or its associated control pages follow the steps below 1 In the Configurator go to the Desig...

Страница 139: ...om selection to configure a screen size with the Resolution drop down menu below it Note If you select Custom Windows Device the Windows OS has a limitation for adding buttons to Viewers used on Windo...

Страница 140: ...f the Control Box Controller that the Keypad will connect through This ID must match the controller ID Switch black set on the Keypad see page 62 Keypad ID Select the ID number to match the Keypad ID...

Страница 141: ...his setting Controller ID Displays the Control Pad ID Setting Description Type Use this drop down menu to select the Touch Panel that will be used to control hardware devices in a room Resolution Indi...

Страница 142: ...ontrol Description Click to duplicate the Viewer along with the pages Click to edit the basic Viewer settings that you configured in step 3 Click to add a new page to the highlighted Viewer in the lef...

Страница 143: ...following methods to open the page you wish to configure Click the page from the left sidebar Click its associated Viewer from the left sidebar and then click to open a page The page opens in a tab F...

Страница 144: ...out on the preview scroll the mouse wheel To relocate an object drag and drop the object To layer an object right click the object and set the Order options To group multiple objects drag the mouse to...

Страница 145: ...ry to customize the appearance of the page and its buttons For more information see Library page 115 Button Action or Slider Bar Action Use this panel to define the functions of each button and slider...

Страница 146: ...bers are assigned in sequence in the order that the object is added These numbers help identify a label when configuring a Change Label page 167 or a button when configuring a Change Button State page...

Страница 147: ...4 ATEN Configurator VK6000 129 Buttons The Button properties provide options to configure the appearance of a button and the confirmation message and progress message before carrying out the associate...

Страница 148: ...tween two images colors when pressed and released This button continuously re sends a command to a device as long as it is pressed at the Interval specified see Interval below and stops sending the co...

Страница 149: ...Image Size to reset the button size Reset Image Size click to reset the button size Set Sync Condition automatically synchronizes the button setting to the selected variable To create variables see V...

Страница 150: ...Name field and optionally customize its font and style Message Click the Message tab to set up a progress message that displays while the associated action is being carried out Note The Message setti...

Страница 151: ...our group of components have different properties will be open for configuration Use your mouse to drag and select the components from a page the properties that are open for configuration appear in t...

Страница 152: ...u to change the color of the text Size enter a number 1 200 to set the size of the text Format format text to Bold Italic or Underline Alignment click a box to align the text Right Center or Left and...

Страница 153: ...Chapter 4 ATEN Configurator VK6000 135 Slider Bars Right click on a Viewer page and select Slider Bar to add a bar A Slider Bar can control a device link to another page or run a macro...

Страница 154: ...each level with the formula Maximum Value Minimum Value Level Value Per Level The Level is automatically calculated according to the Minimum and Maximum values you enter Position and Size depending o...

Страница 155: ...rol template or a media control template to configure its position size and the PC that controls it Position and Size X and Y position the label at the coordinates entered Width and Height set the siz...

Страница 156: ...Same Size or Space Evenly from the Object menu Note For imported images make sure the file names contain English alphabets and or numerals only Style shows the image selected Click inside the box to i...

Страница 157: ...4 ATEN Configurator VK6000 139 Layering Images Images can be layered with other objects such as labels and buttons so that they can be placed as a background or as highlight for the page and or other...

Страница 158: ...ATEN Control System User Manual 140 Videos A video template is a control object used for previewing videos and assigning video sources for the managed displays...

Страница 159: ...re objects on the Viewer which allows you to see previews of video sources on a source object or the assigned video sources on a display object and to switch video sources by tapping or dragging and d...

Страница 160: ...mitters when adding extenders to the Device Configuration list To ensure preview quality it is recommended to add at least one video transmitter to the Device Configuration list for every 4 video cont...

Страница 161: ...iable to store the video source on a source object b Add the switching action on a display object For more information about creating actions see Button Slider Bar Dial Kit Actions page 150 Note To en...

Страница 162: ...l 144 Dial Kit A dial kit template consists of a display screen and a set of dial keys To configure their appearance click on the display area or a key Display Screen Dial Keys Properties for Display...

Страница 163: ...ect this option to import different images for the dial key when it is pressed and not pressed normal Transparency enter a number 0 100 or use the slider bar to set the transparency of the button Colo...

Страница 164: ...onfigure the color format and width of the line or border of the frame Rounder corder use the scroll bar or the number box to configure the roundness of the frame corner Fill select this option to fil...

Страница 165: ...rties for ATEN Keypad Control Pad After you have added a Viewer page 120 for your Keypad Control you can start configuring the Viewer In the Viewer page click on a button to configure its settings The...

Страница 166: ...ed Note Use the Normal or Long Press option to set the image color of the button based on its status Name optional type the text you want to use for the button or slow double click the button on the V...

Страница 167: ...sition the button at the coordinates entered Width and Height set the size of the button box Set Sync Condition Automatically synchronizes the button to the selected variable To create a variable see...

Страница 168: ...oms in the KNX system and display KNX devices The Viewer will only upload to a controller configured with the same Room name see Left Sidebar page 100 Select All Rooms to allow the Viewer to control a...

Страница 169: ...o c commands Toggle ON Press lists the commands that initiate when the button is first pressed or pressed and held Toggle OFF Release lists the commands that initiate when the button is pressed a seco...

Страница 170: ...tton Slider Bar Action panel appears 2 In the Button Slider Bar Action panel select a Room 3 Add commands For details on device functions and advanced functions see Functions page 153 a Click a device...

Страница 171: ...ons Device functions These are functions that the selected controller or a device managed by the controller initiates The supported device functions vary depending on the device you select in the Devi...

Страница 172: ...These are functions that involve more than one devices in the project Use the indicated column to select an advanced function the available options are listed in the Function list For details about e...

Страница 173: ...and in the HEX mode UDP Raw ASCII adds a UDP command in the ASCII mode UDP Raw HEX adds a UDP command in the HEX mode HTTP adds an HTTP command HTTPS adds an HTTPS command Value Types When a device co...

Страница 174: ...for the Basic Slider Bar This option only appears when a Basic Slider Bar is selected on the Viewer page and you are adding Slider Bar Action commands Note The Show Flag Menu allows you to use a sing...

Страница 175: ...are pre configured to send out the number or character as indicated on the keys Follow the steps below to add an action to the Call key 1 Click the Call key in the Viewer to display the Button Action...

Страница 176: ...can be used by two or more control objects e g slider bar or buttons in the Viewer This function is used when you have more than one Viewer objects controlling the same device Note To complete this s...

Страница 177: ...A Manual Change Label can be added to the beginning or end and with a Condition in the Commands list Adding it to a Condition guarantees the label only changes when the command initiates Change Group...

Страница 178: ...tiate in the order listed Set Flag Adds a Set Flag to change a Flag s value when a command changes a device setting This sets the Flag value to match the new device setting e g ON or OFF Always add a...

Страница 179: ...Flag s value If Flag equals Value is true the condition is met and the commands listed with the Condition will initiate Always add a Condition Flag at the top of the Commands list drag and drop the de...

Страница 180: ...erial telnet TCP command with command s added below the Condition Feedback in a tree view list Receive Time when a Feedback condition is added to a device command the wait to Receive Time drop down me...

Страница 181: ...esult A Change Label must be added to the Feedback Bypass for it to work To add a Condition Feedback Equal Include 1 Under Device click Condition 2 From the Function list select Feedback 3 From the Fu...

Страница 182: ...ge Label 1 Under Device click Condition 2 Select Feedback from the Function list 3 From the Function list drag and drop Feedback to add it to the Serial Telnet TCP command in a tree view list 4 Double...

Страница 183: ...r Page to add it to the Feedback Bypass Condition in a tree view list 8 Double click Change Label in the Commands list and use the drop down menu to select a label Labels are identified by number see...

Страница 184: ...tton allows the image to switch with the toggle behavior Normal or Pressed To add a Change Button State 1 Under Properties use the Mode drop down menu to select a button type 2 Under Style click the N...

Страница 185: ...the Viewer page to add it to the end of the Toggle ON commands in the Commands list 7 Select the Toggle OFF radio button then in the Function list double click the Viewer page to add it to the end of...

Страница 186: ...iates To add a Manual Change Label 1 Under Device click Change Label 2 In the Function list select the Viewer page where the label is located 3 Double click or drag and drop the Viewer page to add the...

Страница 187: ...Add a Change Group Button State independently or with a device command To add a Change Group Button State 1 Under Device select Change Group Button State 2 From the Function list select the Viewer Pag...

Страница 188: ...vel independently or with a device command To add a Change Slider Bar Level 1 Under Device select Change Slider Bar Level 2 From the Function list select the Viewer Page where the Slider Bar is locate...

Страница 189: ...device Example Indicate the currently assigned source on a display device in the Viewer Assume an environment consisting of one monitor and five sources buttons computer laptop camera etc as illustra...

Страница 190: ...ample double click the Video Wall option The Change Button Name command is added 4 From the Commands list double click the Change Button Name command and configure the following Select the ID of the d...

Страница 191: ...y to use graphics for backgrounds buttons icons and device interfaces Device Interface provides entire page layouts that you can use as templates for different types of devices Double click or drag an...

Страница 192: ...ATEN Control System User Manual 174 Icon Device Interface...

Страница 193: ...and Query port monitors which check a device s status to initiate actions For details see Monitor page 178 Macro Macros initiate a sequence of actions on one or more hardware devices For details see M...

Страница 194: ...lue is OFF Set Flag changes the flag value when a device setting has changed So that if a device is OFF and the action turns the device ON adding a Set Flag 1 to ON will change the flag value to ON No...

Страница 195: ...hown below Name Lists the Flag names which have been created Value Lists the flag s values or range of values Default Lists the flag s default value x Deletes a flag from the list 4 Select Condition o...

Страница 196: ...ription Type Use this drop down list to select a monitor type If select this option for a single condition monitor If the single condition is met the action initiates For details see Creating an If Mo...

Страница 197: ...tion to create the commands that will initiate when the monitor s conditions are met For details see Device Functions page 155 and Advanced Functions page 158 Click to hide or display the Device and S...

Страница 198: ...k Edit Return Message icon and do as explained below Edit Return Message Listen to port Query port Next configure the parameters for the return message from the device This message must match for the...

Страница 199: ...ick Apply The return message will need to fit the fixed string of characters set in the text box next to the Drop Down Menu see below for the monitor to be triggered Drop Down Menu Above enter charact...

Страница 200: ...etting for the port Digital Input VDC High states that when the voltage signal is above the Upper Threshold to initiate the Action Low states that when the voltage signal is below the Lower Threshold...

Страница 201: ...n the ASCII mode Serial Raw HEX adds a serial command in the HEX mode Telnet Raw ASCII adds a telnet command in the ASCII mode TCP Raw ASCII adds a TCP command in the ASCII mode TCP Raw HEX adds a TCP...

Страница 202: ...etups that require multiple events from hardware devices connected to multiple conditions Most devices only require one signal Status added to the Condition List to initiate an Action Most installatio...

Страница 203: ...add a device port or flag to the Condition list Then double click the device port or flag in the Condition list to configure the condition settings Note To set the controller as a TCP server use the...

Страница 204: ...t to the Commands list This Command initiates when the Condition is met For details on Functions and Commands see Device Functions page 155 and Advanced Functions page 158 Note If you have configured...

Страница 205: ...condition comparisons as explained below Type Use the drop down menu to select If select this option for a single condition comparison monitor Switch select this option for multi condition comparison...

Страница 206: ...re Edit Return Message to configure see Edit Return Message page 180 To set the controller as a TCP server use the TCP Server option in the Status column and make sure to type a TCP server port in the...

Страница 207: ...Chapter 4 ATEN Configurator VK6000 189 Note For more information about Functions see Button Slider Bar Dial Kit Actions page 150...

Страница 208: ...et For details on what each function does see Device Functions page 155 and Advanced Functions page 158 Note If you have configured the controller as a TCP server add TCP Feedback Raw ASCII or TCPFeed...

Страница 209: ...ond drop down list select one of the following Listen to port actively listens for a message from the specified device Query port when a setting is changed on the specified device the device sends a f...

Страница 210: ...Use the Query Frequency drop down menu to define the frequency at which the device checks for signals 3 From the Device list select a device 4 Optional Select an advanced option For details see Advan...

Страница 211: ...rt number of the assigned source on each of the four screens on a Viewer page as illustrated below For the controller to print the port number of the assigned source on each screen and keep this infor...

Страница 212: ...Define the query frequency 4 Configure the condition settings In this example the controller VK2100 is set to query the input and output ports of the Matrix Switch VM6404H that connects to the contro...

Страница 213: ...pen status e g input_io h In this example use Script Editor to Convert data format Create four variables representing the assigned input for each screen In this example InputNToOutput1 InputNToOutput2...

Страница 214: ...heir corresponding IDs As long as the ID does not change the command name can change The same ID cannot be used for two different commands The same applies to command names vk_hex_to_ascii Converts st...

Страница 215: ...lowing multiple devices to initiate actions all at once from one button For example you can create a macro to start a video presentation by adding functions to dim lights power on source power on disp...

Страница 216: ...hardware under Device and add the Function to the Commands list Note For more information about adding Functions see Button Slider Bar Dial Kit Actions page 150 4 After adding all the functions to th...

Страница 217: ...event 4 Configure event actions a In the Device column select a device b In the Function column double click the desired functions The corresponding commands appear in the Commands column For details...

Страница 218: ...is useful for automatic synchronization of device settings especially when you have two or more objects in a Viewer controlling a single device setting Take the example of controlling a speaker volum...

Страница 219: ...target device Setting range Type two numbers to define the range for the variable Valid numbers include negative numbers and numbers that contain one decimal place Note If one of the numbers contains...

Страница 220: ...ure the Value settings in Properties c In Properties click Set Sync Condition and select the variable you created using the drop down list 3 Create a Monitor to set up the conditions for which the dev...

Страница 221: ...click c Configure the following settings Name Type a name for the Variable String format Select the string format for the target device Setting range Type two numbers to define the range for the vari...

Страница 222: ...ure value settings in Properties c Click Set Variable and then double click the Variable you created in step 1 d In Properties click Set Sync Condition and select the Variable you created using the dr...

Страница 223: ...to 0 i e the condition is Variable 0 the action will be to change the speaker volume to 0 as illustrated below e Repeat steps 2 c and 2 d to add one or more actions to each condition 4 If you select E...

Страница 224: ...g information is available in the Unizon platform connection status with Unizon current IP address firmware version license usage only applicable to ATEN controllers You can also create parameters to...

Страница 225: ...gement via Unizon a Open the target project and go to the Device tab b In the Unizon column select devices for remote management via Unizon For example 2 Optional Create parameters for monitoring and...

Страница 226: ...e click and then select Add Monitor Item in a pop up dialog box A new monitor item is added 3 Double click the header Monitor Item to rename the parameter Example Rename it to Lamp Hour 4 Create a var...

Страница 227: ...t Sync Condition dialog box appears c In the General tab click the first drop down menu and select Create Variable to create a variable For details about creating variables see Variables page 200 d In...

Страница 228: ...ATEN Control System User Manual 210 e Optionally set up alerts for this monitor item For example...

Страница 229: ...y of the target device to open the configuration page Example To add a control item to a Video Matrix click Video Matrix Switch 2 In the configuration page click and then select Add Control Item in a...

Страница 230: ...ick Create Proceed to create all the control options as required Example Type Input 1 and click Create Add Input 2 3 and 4 c Click Input 1 and add the action in the Action panel Proceed to configure e...

Страница 231: ...Chapter 4 ATEN Configurator VK6000 213 Removing a Monitor Control Item To remove a monitor or control item right click the header and select Delete...

Страница 232: ...trollers To back up a project and its Viewers to a controller 1 Browse for the ATEN controller where you wish to save the configured Viewers Auto Search Browses for controllers on the same LAN with th...

Страница 233: ...the controller ID specified in this project file 3 Optionally click on the following to configure password authentication settings Note Due to security concerns the access key of any ATEN controller...

Страница 234: ...ey is not required to upload Viewers to the controller and download Viewers from a mobile device The access key has been changed on the controller s web interface Dashboard To change the lock status c...

Страница 235: ...a new license file Reset License Resets all license s in use by mobile devices This will disconnect all mobile device connections to the controller Firmware Version Displays the firmware version Capa...

Страница 236: ...ATEN Control System User Manual 218 This Page Intentionally Left Blank...

Страница 237: ...ablish and store commands for operating devices managed by ATEN Control System and reuse them when configuring Viewers Accessing the Database Generator In ATEN Configurator goto Tools Database Generat...

Страница 238: ...o My Library Add Device from Driver File Add devices from a database file vkd to My Library Check Box Click Do not show this dialog again to prevent the dialog from appearing when the Database Generat...

Страница 239: ...elected to configure ports on the controller My Library lists all the hardware devices that you have created added and edited using the Database Generator You can create new hardware devices or add ex...

Страница 240: ...add to Device Library Add Device from ATEN Device Library Add devices from the ATEN Device Library to My Library Add Device from Driver File Add devices from a data base file vkd to My Library Export...

Страница 241: ...o Set the Language Show Add Device dialog on startup Show IR Learning tips Set the IR Learning Timeout how long to attempt a connection to an IR device before IR learning stops Library Provides a list...

Страница 242: ...ver file Use the check boxes to select individual devices or All to select the entire list Click to add a new custom device to the database Select a device and click this icon to create a duplicate Cl...

Страница 243: ...All Serial IR DO Relay or Ethernet to filter the list by type Click Brand Category Model Type or Version to sort the devices Click Export Selected Device to save the selected devices Click Delete Sele...

Страница 244: ...tes about the updates being made to the device configuration You can create and use different versions of the same device and track the changes The version history can be viewed and different versions...

Страница 245: ...allows the text to be edited from the VK6000 in the Button Action Commands list see page 152 Click to add a drop menu into a Command string then enter the number sequence in the brackets The Function...

Страница 246: ...back Timeout Sets the maximum interval that the controller allows in between parts of a feedback message If the controller has not received any feedback for longer than the specified Feedback Timeout...

Страница 247: ...tore feedback and or queries for the corresponding command For more information about adding feedback see Testing Commands page 239 For more information about creating queries see Configuring Queries...

Страница 248: ...t command itself Example Power On 0A Power Off 0B Standby Mode 0C this command string will provide a drop down menu with three choices using the text before the equal signs to describe each command fr...

Страница 249: ...oller Function List Use this section to configure the IR functions by adding actions to the list Quick Mode Click to run Learning Mode for all IR actions in the Function List When the Quick Mode windo...

Страница 250: ...he remote s button then you must press the button in the same manor long hold or quick tap when it using for Learning mode The Control Box will beep and the Learn LED will light solid then turn off wh...

Страница 251: ...drop down menu to set a timed delay for each command before it is sent to the device Function List Use this section to configure the Digital Output device functions by adding actions to the list Func...

Страница 252: ...drop down menu to set a timed delay for each command before it is sent to the device Function List Use this section to configure the Relay device functions by adding actions to the list Function Lists...

Страница 253: ...n the Button Action Commands list see page 152 Click to add a drop menu into a Command string then enter the number sequence in the brackets The Function name must include an asterisk for each drop me...

Страница 254: ...send to the device after a successful connection has been established Auth Type Sets the authentication type for the device Timeout Specifies the maximum time that the device allows for receiving each...

Страница 255: ...is entered in the Function name Command Shows the command string created for the action To edit a command for a Telnet PJLINK ONVIF or TCP compliant device double click the Command field green area in...

Страница 256: ...across a network device such as a router or switch you must specify the IP address Search by IP address Enter the IP address and click Search to locate a controller Controller ID Use the check box to...

Страница 257: ...vice and configure the required settings if any in the select controller window click OK to proceed to test the typed command The Test Command window appears Select which device to send command to by...

Страница 258: ...the window and the feedback messages listed in the Feedback column Add Click to save a feedback message in the Saved Feedback message window Pause Continue Click to pause sending receiving the comman...

Страница 259: ...o estimate the remaining lifespan and plan for replacement in advance 1 In Database Generator click Edit to enter the settings page for the projector 2 Add a command by clicking and double click the c...

Страница 260: ...ATEN Control System User Manual 242 c Write up a script to create a variable that stores the requested value in this case the cumulative lamp hour d Click Save...

Страница 261: ...ded to My Library the device settings can be edited as needed Use the check boxes to select devices to add to My Library Check All to select all devices in the list Key in word strings then click Sear...

Страница 262: ...ATEN Control System User Manual 244 This Page Intentionally Left Blank...

Страница 263: ...rol such as shutting down the computer execute command prompt set system volume and run a program Note For a full list of supported actions see Supported PC Control Actions page 256 Specifications Sup...

Страница 264: ...le formats Category File Formats Windows Media format asf wma wmv wm Windows Media Metafiles asx was wvx wmx wpl Microsoft Digital Video Recording dvr ms Windows Media Download Package wmd Audio Visua...

Страница 265: ...teps see Adding Target Computers to the Control System page 250 4 Create a control interface to be used on a licensed mobile device For detailed steps see Configuring a Control Interface page 252 For...

Страница 266: ...te Key or About ATEN ControlAssist to access the following settings information Control Default Description Basic Settings The settings with which an ATEN controller needs to establish connection with...

Страница 267: ...templates file list To display files at the computer s partition level type MY_COMPUTER in this field Upload SSL Certificate and Private Key Upload an SSL certificate and its private key to secure ses...

Страница 268: ...you wish to control follow the steps below to establish connection between the controller and the target computers 1 From ATEN Configurator locate and open your project file 2 Click the Device tab an...

Страница 269: ...as an Ethernet device installed with ControlAssist appears in the Device Configuration List 6 Select the newly added device and configure the Properties settings on the right of the interface Hint If...

Страница 270: ...folder see page 247 in the target computer You can follow the same logic for creating a media control page 1 In the Design tab make sure your home page contains a presentation button and the Viewer co...

Страница 271: ...r template a In the left sidebar click PowerPoint b In the PowerPoint page right click any blank spot and select PowerPoint Control Template A pre made screen is added c In the Properties column use t...

Страница 272: ...and add control buttons using the Properties settings in the right hand column For details see Configuring Control Interfaces page 117 2 Define the action of each button For example for the PowerPoin...

Страница 273: ...ote PC Control 255 For details on supported control actions see Supported PC Control Actions page 256 3 From the Upload tab deploy and back up the project to the controller For details see The Upload...

Страница 274: ...o a specified volume Stop Stops the playback Switch to full screen mode Enables or disables the player to full screen display Switch to mute mode Enables or disables mute mode Switch to repeat mode En...

Страница 275: ...e desktop Hotkey Control Create action Executes the associated hotkey s on the program that opens topmost on the computer desktop For example if you have Ctrl f defined as the hotkey for extending a p...

Страница 276: ...ATEN Control System User Manual 258 This Page Intentionally Left Blank...

Страница 277: ...nstalling the App To install the ATEN Control System App on a mobile device do the following 1 From the mobile device tap the App Store or Google Play icon 2 In the search box type aten control 3 Tap...

Страница 278: ...n appears Tap Demo to try the ATEN Control System app Tap Start to find a controller and download Viewers see Welcome page 265 Note The default demo start screen appears until a Viewer is downloaded t...

Страница 279: ...Viewer to view the controls of different hardware devices To return to the demo start page tap Quit Demo at the top right corner Select a Viewer or press any of the buttons on the Welcome page to dem...

Страница 280: ...TEN Control System User Manual 262 This demo shows a Conference call interface with controls for a Projector Screen and Lighting Tap any of the device icons to open each of the following control pages...

Страница 281: ...ent buttons that can be pressed to control the Projector Lights Video Wall and Camera Tap the icons to view control pages for each device Tap the Quit Demo icon to return to the previous page or press...

Страница 282: ...l 264 The images above show control pages for the Projector Lights Video Wall and Camera in Demo Tap the Home icon in the lower left corner to return to the previous page or press on the background un...

Страница 283: ...Description Manage Viewer Use this page to add update and remove downloaded Viewers See page 267 for details Manage LANDevice Use this page to access controller s web console or configure the network...

Страница 284: ...ATEN Control System User Manual 266 Information This page provides information about the ATEN Control System s software version See page 275 for details Icon Description...

Страница 285: ...roller associated with the Viewer Update Tap Update to connect to the controller and download an updated version of the Viewer After the update the Downloaded Successfully prompt will appear Remove Ta...

Страница 286: ...vice page allows you to edit network settings for the controllers and LAN devices added in the Configurator software see Device Library page 116 Tap to expand controllers to view connected LAN devices...

Страница 287: ...l System App 269 Depending on the LAN device you select different options are available Tap on a device to open the settings page Use Edit to change settings Apply to save or OK to exit Controller PJL...

Страница 288: ...ATEN Control System User Manual 270 ONVIF TCP UDP...

Страница 289: ...password authentication for accessing the app Allow keyboard usage when this app is in full screen Enable this option to allow keyboard operation when the app is in full screen Notify me when this ap...

Страница 290: ...xamples see page 261 in full screen Show minimize maximize and close buttons This setting is only available when using the app on a Windows platform Enable this setting to show the minimize maximize a...

Страница 291: ...ts information and errors which can be used to troubleshoot issues Tap and drag the list to scroll through the logs Tap Back to exit Tap Save to save the log file Tap Report History to view saved logs...

Страница 292: ...port History you can view and export logs Saved log files are listed by date in the left column Tap a log file to view it in the window to the right Tap and drag the list to scroll through the logs Ta...

Страница 293: ...Chapter 7 ATEN Control System App 275 Information The Information page displays the ATEN Control System s version...

Страница 294: ...rop down menu will appear for previously searched IP addresses Auto Search Auto Search allows you to search for controllers without specifying an IP address The controller must be powered on and conne...

Страница 295: ...ccess key After Viewers download the Downloaded Successfully prompt appears Tap Done to return to the Welcome page where the Viewers will be listed Note After you download a Viewers to the mobile devi...

Страница 296: ...ATEN Control System User Manual 278 This Page Intentionally Left Blank...

Страница 297: ...ust never be blocked or covered The device should never be placed on a soft surface bed sofa rug etc as this will block its ventilation openings Likewise the device should not be placed in a built in...

Страница 298: ...or water The device has been dropped or the cabinet has been damaged The device exhibits a distinct change in performance indicating a need for service The device does not operate normally when the op...

Страница 299: ...out of a rack the slide rails can pinch your fingers After a device is inserted into the rack carefully extend the rail into a locking position and then slide the device into the rack Do not overload...

Страница 300: ...Pole Terminal Block Connector Normally open isolated Relays Contact Rating Max 24 VDC 1A Digital Input 1 x Digital Input Channel 1 x 2 Pole Terminal Block Connector VDC Mode Input Voltage Range 0 to 5...

Страница 301: ...44W 7BTU Environmental Operating Temperature 0 50 C Storage Temperature 20 60 C Humidity 0 80 RH Non Condensing Physical Properties Housing Plastic Weight 0 35 kg 0 77 lb 0 38 kg 0 84 lb Dimension 11...

Страница 302: ...ontrol None default RTS CTS IR Serial 2 x Programmable IR Unidirectional RS 232 Ports 1 x 3 Pole Terminal Block Connectors IR Carrier Frequency 10KHz 455KHz Serial Baud Rate 300 to 115200 default 9600...

Страница 303: ...SB Type A Switches Controller ID 1 x 16 Segment Switch Power 1 x on off Switch IR Learning 1 x IR Receiver LED Reset Button 1 x Semi recessed pushbutton Power Power Consumption AC110V 5 4W 87BTU AC2V...

Страница 304: ...0 default 9600 Data Bit 8 default or 7 Stop Bit 1 default or 2 Parity None default Even or Odd IR Serial 4 x Programmable IR Unidirectional RS 232 Ports 2 x 4 Pole Terminal Block Connectors IR TTL lev...

Страница 305: ...H DHCP enabled Default IP settings IP address 192 168 0 60 subnet mask 255 255 255 0 will be automatically applied if no IP address is assigned after connecting to the network for 30 seconds USB 1 x U...

Страница 306: ...ATEN Control System User Manual 288 Physical Properties Housing Metal Weight 2 64 kg 5 81 lb Dimensions L x W x H 43 72 x 16 32 x 4 40 cm 17 21 x 6 43 x 1 73 in...

Страница 307: ...ngle 85 H 85 V Interfaces Ethernet 1 x 4J 45 Female 10 100 1000 BaseT USB 1 x USB Type A Power Power over Ethernet PoE 802 3 af PoE 802 3 at PoE Power Consumption DC48V W Environmental Operating Tempe...

Страница 308: ...nector Baud Rate 300 115200 default 9600 Data Bit 8 default or 7 Stop Bit 1 default or 2 Parity None default Even or Odd Flow Control None default RTS CTS for 5 pole terminal block IR Serial 2 x Progr...

Страница 309: ...DC 2 A V DC 1 x 12 V DC Output Port 1 x 2 Pole Terminal Block Connectors Power Supply 12 V DC 1 A Max Ethernet 2 x RJ 45 Female 10 100 1000 Base T Supported protocol ARP ICMP TCP IP DHCP HTTPS SSH DH...

Страница 310: ...sumption AC 110 V 4 7 W 81 BTU AC 220 V 4 5 W 81 BTU Maximum Input Power Rating internal power 100 240 V AC 50 60 Hz Environmental Operating Temperature 0 50 C Storage Temperature 20 60 C Humidity 0 8...

Страница 311: ...300 115200 default 9600 Data Bit 8 default or 7 Stop Bit 1 default or 2 Parity None default Even or Odd Flow Control None default RTS CTS for 5 pole terminal block IR Serial 8 x Programmable IR Unidi...

Страница 312: ...V DC 4 x 12 V DC Output Ports 2 x 4 Pole Terminal Block Connectors Power Supply 12 V DC 2 A Max Shared By 4 Ports Ethernet 2 x RJ 45 Female 10 100 1000 Base T Supported protocol ARP ICMP TCP IP DHCP H...

Страница 313: ...W 139 BTU AC 220 V 6 8 W 144 BTU Max Input Power Rating Internal power 100 240 V AC 50 60 Hz Environmental Operating Temperature 0 50 C Storage Temperature 20 60 C Humidity 0 80 RH Non condensing Phy...

Страница 314: ...for Mobile Control VK1100 VK2100 Basic free 2 Max No Allowed 16 Licenses for Mobile Control VK0100 VK0200 Basic free 0 Max No Allowed 10 Note Each time a mobile device or a Touch Panel connects to an...

Страница 315: ...Appendix 297 CAD and Panel Cutout Diagrams VK0100 Replace with VK0100 CAD Cutout diagrams...

Страница 316: ...ATEN Control System User Manual 298 Replace with VK0100 CAD Cutout diagrams...

Страница 317: ...Appendix 299 Replace with VK0100 CAD Cutout diagrams...

Страница 318: ...ATEN Control System User Manual 300 Replace with VK0100 CAD Cutout diagrams...

Страница 319: ...Appendix 301 VK0200 Replace with VK0200 CAD Cutout diagrams...

Страница 320: ...ATEN Control System User Manual 302 Replace with VK0200 CAD Cutout diagrams...

Страница 321: ...Appendix 303 Replace with VK0200 CAD Cutout diagrams...

Страница 322: ...ATEN Control System User Manual 304 Replace with VK0200 CAD Cutout diagrams...

Страница 323: ...Appendix 305 VK108US Replace with VK108US CAD Cutout diagrams...

Страница 324: ...ATEN Control System User Manual 306 Replace with VK108US CAD Cutout diagrams...

Страница 325: ...Appendix 307 Replace with VK108US CAD Cutout diagrams...

Страница 326: ...ATEN Control System User Manual 308 Replace with VK108US CAD Cutout diagrams...

Страница 327: ...Appendix 309 VK112EU Replace with VK108US CAD Cutout diagrams...

Страница 328: ...ATEN Control System User Manual 310 Replace with VK108US CAD Cutout diagrams...

Страница 329: ...Appendix 311 Replace with VK108US CAD Cutout diagrams...

Страница 330: ...ATEN Control System User Manual 312 Replace with VK108US CAD Cutout diagrams...

Страница 331: ...B1 DPT_UpDown 1 009 B1 DPT_OpenClose 1 010 B1 DPT_Start 1 011 B1 DPT_State 1 012 B1 DPT_Invert 1 013 B1 DPT_DimSendStyle 1 014 B1 DPT_InputSource 1 015 B1 DPT_Reset 1 016 B1 DPT_Ack 1 017 B1 DPT_Trig...

Страница 332: ...inds 4 001 A8 DPT_ASCII 4 002 A8 DPT_Char_8859_1 5 001 U8 DPT_Scaling 5 003 U8 DPT_Angle 5 004 U8 DPT_Percent_U8 5 005 U8 DPT_DecimalFactor 5 006 U8 DPT_Tariff 5 010 U8 DPT_Value_1_Ucount 6 001 V8 DPT...

Страница 333: ...e 20 108 N8 DPT_ValveMode 20 109 N8 DPT_DamperMode 20 110 N8 DPT_HeaterMode 20 111 N8 DPT_FanMode 20 112 N8 DPT_MasterSlaveMode 20 113 N8 DPT_StatusRoomSetp 23 001 N2 DPT_OnOff_Action 23 002 N2 DPT_Al...

Страница 334: ...but retains the network and license settings OFF While pressing and holding turn on the Control Box and release when the buzzer beeps once with the front panel LEDs blinking Enters Recovery Mode with...

Страница 335: ...en two or more buttons are layered on one another such as A on top of B users are unable to press the top most button A and instead triggers the bottom button B every time trying to press A To resolve...

Страница 336: ...ready beforehand Product model number serial number and date of purchase Your computer configuration including operating system revision level expansion cards and software Any error messages displaye...

Страница 337: ...option to 1 repair said product with new or repaired components or 2 replace the entire product with an identical product or with a similar product which fulfills the same function as the defective pr...

Страница 338: ...ATEN Control System User Manual 320...