IP67 INCREMENTAL ROTARY ENCODER
USER MANUAL
ARK S 58 series rotary encoders measure with magnetic principle and work contactless. They give
incremental digital pulse signal output.
They have different resolution values between 1 pulse and 1024 pulses. With their high IP67
protection class, they can work in harsh environmental conditions.
Optionally, different cable length, socket model and shaft diameter can be requested.
GENERAL INFORMATIONS
•
The installation of the product is carried out by the customer who purchases the product, according to the wiring diagrams,
installation information, etc. in this manual.
•
Maintenance and repair should be done by the technicians authorized by the manufacturer firm.
•
There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless
it needs.
•
Keep away the sensor cable from as high power energy cables, contactor, motor, switched power supplies, inductive and
capacitive noisy supplies.
•
Shielding edge of the sensor cable must be ground connected.
•
Not to damage the sensor supply directions and voltage must be paid attention (For TTL sensor max. 5V; PP, HTL, HPL sensor
max
. 30V). Don’t energize before all connections completed.
•
Transport and storage should be at their original packaging and an ambient temperature of -
40°C / +85°C in such a way that
they will not be exposed to dust, humudity, impact, vibration, falling or water.
•
Chemicals such as alcohol, thinner etc. should not be used for cleaning the product. The product should be wiped with a
damp cloth.
•
The product may be damaged and may become unusable if used outside of the specifications in the user manual.
•
The product will be out of warranty if used outside of the specifications in the user manual and opened or repaired other
than authorized services.
WARNINGS
M16 / 8 PIN MALE
SOCKET PIN NO
SIGNAL
CABLE COLOR
1
A
YELLOW
2
/B
WHITE
3
+V
RED
4
0 V
BLACK
5
/A
BLUE
6
B
GREEN
7
/Z
GREY
8
Z
PINK
ELECTRICAL CONNECTIONS
In the left tablet he cable colors of sensors output signals are given. If the control circuit is suitable in the Line Driver
sensors of the not output signals (/A, /B, /Z) have to be added to the system. If it is not suitable /A, /B, /Z signal cables
must be fixed as insulated separately. Don
’t forget that these edges have electricity too.
A
/A
B
/B
Z
/Z
90
°