SERIAL NUMBER OF THE INSTRUMENT 

You can find the Series Number on the rear panel of the instrument. 
Series Number is in the form: 0000X00000. 
The first four digits and the letter are the Series Number prefix, the last five digits are 
the Series Number suffix. The prefix is the same for identical instruments, it changes 
only when a configuration change is made to the instrument. 
The suffix is different for each instrument. 

Document PA6001EN-70601 – Copyright © NARDA 2017 

User’s Manual

PMM PA6001

WIDEBAND RF POWER 

AMPLIFIER 

100 kHz - 250 MHz / 40 Watts

Provided by:

www.atecorp.com

(800) 404-ATEC

Advanced Test 

Equipment Rentals

®

Содержание PMM PA6001

Страница 1: ...ear panel of the instrument Series Number is in the form 0000X00000 The first four digits and the letter are the Series Number prefix the last five digits are the Series Number suffix The prefix is the same for identical instruments it changes only when a configuration change is made to the instrument The suffix is different for each instrument Document PA6001EN 70601 Copyright NARDA 2017 User s M...

Страница 2: ...fier Before using the equipment the user must insure that all instructions at switch on as indicated in chapter 2 have been properly made and checked The information contained in this document is subject to change without notice SAFETY SYMBOLS Warning danger of electric shock Read carefully the Operating Manual and its instructions pay attention to the safety symbols EARTH PROTECTION ...

Страница 3: ... Weight of the equipment 2 5 Moving of the equipment 2 6 RF interconnections 2 7 Switch on for 1st check step 2 8 Switch off for 1st check step Page 2 1 2 1 2 1 2 1 2 2 2 2 2 2 2 2 3 Instructions for use 3 1 Front panel in standard configuration 3 2 Operation instructions 3 2 1 Switch on 3 3 Operation 3 3 1 Power measurement 3 3 2 Excess direct power 3 3 3 Mismatch 3 3 4 Temperature 3 3 5 Switch o...

Страница 4: ...IV Contents Figures Figure 1 1 3 1 4 1 PA6001 PA6001 Auxiliary earth conductor connection PA6001 front panel Page 1 1 3 1 4 1 Tables Table 1 1 Main Specifications PA6001 Page 1 2 ...

Страница 5: ...rective 2004 108 CE Inside the shielding area other test equipments could be disturbed For safety reasons do not leave the equipment under mains voltage when the RF output is not connected Before using the amplifier the input level of the signal generator must be checked 0 dBm typical 10 dBm max Special care must be taken with regards to the level of radiation of all equipments connected to the am...

Страница 6: ...SV Italy sulla base delle seguenti norme europee armonizzate applicate con esito positivo based on the following harmonized European Standards successfully applied EMC Emissioni EMC Emission EN 61326 1 2013 EMC Immunità EMC Immunity EN 61326 1 2013 Sicurezza Safety EN 61010 1 2010 dichiara sotto la propria responsabilità che il prodotto declares under its sole responsibility that the product Descr...

Страница 7: ...xponential etc The PA6001 amplifier is manufactured to operate in a CW mode CW with a single instantaneous range from 100 kHz to 250 MHz The typical output power is about 40 watts minimum on a 50 ohms load The equipment operates under any VSWR conditions It can deliver a high RF current under short circuit conditions and a high voltage under open circuit conditions This key feature makes the ampli...

Страница 8: ...ltage Rated current Dimensions Weight 100 kHz 250 MHz 40 W 40 W min up to 100 MHz 35 W min from 100 MHz to 250 MHz 35 W min up to 100 MHz 30 W min from 100 MHz to 250 MHz H2 H3 20 dBc for the output power at 1 dB compression limit Class A 43 dB 3 dB max Infinite without damage 50 Ω VSWR 2 1max 50 Ω VSWR 2 1max 10 dBm max Type N fem front or rear panel other connector type on request Type N fem fro...

Страница 9: ... conductor connection See below how to connect the auxiliary earth conductors Fig 2 1 PA6001 Auxiliary earth conductor connection 2 3 Air intake and escape in house installation The air intake is allowed via the front panel and the sides of the equipment The air exhaust is provided on the rear panel horizontal air flow It is imperative to avoid any air flow obstruction and to allow air exhaust tow...

Страница 10: ...able must be 50 Ω in order to allow maximum power operation As this equipment will be used in an EMC test environment we recommend using cable as short as possible and with a length less than 3 meters 2 7 Switch on for 1st check step For this simple check step connect a 50 Ω load to the RF input and output connectors Execute the following operations to switch on the amplifier Install the mains sup...

Страница 11: ...nected to the generator 3 Connector OUTPUT 50Ω N type female to be connected to the load 3 2 Operation Instructions 3 2 1 Switch on Before using the equipment the user must insure that all instructions at switch on as indicated in chapter 2 have been properly made and checked Hazardous live voltage are present connect load before using Connect the generator to the connector INPUT 50 Ω and the load...

Страница 12: ...s when it is higher than the nominal power 3 3 3 Mismatch The load is mismatched when its value varies from its nominal setting of 50 Ω ex 40 or 60 Ω The amplifier allows permanent operation on all impedance conditions However with a mismatched load an important power can be reflected toward the amplifier so the power delivered to the load decreases In case of short circuit the delivered current i...

Страница 13: ...ve components defects The tables in the calibration document show performance after factory acceptance To reproduce these tests it is necessary to use a signal generator a wattmeter and a power load Install between the output of the amplifier and the wattmeter probe A power attenuator or A directional coupler connected to a power load Taking cares to correct the ringing of the attenuator or of the...

Страница 14: ...4 2 Maintenance This page intentionally left blank ...

Страница 15: ...ion you would like to submit to the attention of our service organization is kept in great consideration Moreover we are continuously improving our quality but we know this is a never ending process We would be glad if our present efforts are pleasing you Should one of your pieces of NARDA equipment need servicing you can help us serve you more effectively filling out this card and enclosing it wi...

Страница 16: ...Suggerimenti Commenti Note Suggestions Comments Note ...

Отзывы: