ATD Tools ATD5217 Скачать руководство пользователя страница 1

 

 

 
 

 

ATD5217  

MADE IN MEXICO      

FOR 120 LB. DRUMS 

 
 

 
 
 
 
 
 
 
RETAIN THIS MANUAL FOR FUTURE REFERENCE TO IMPORTANT WARNINGS AND 
OPERATING AND MAINTENANCE INSTRUCTIONS. 
 
PROPER USE AND MAINTENANCE OF THIS EQUIPMENT IS THE RESPONSIBILITY OF THE 
OWNER AND/OR OPERATOR.   
 

DO NOT USE THIS EQUIPMENT UNLESS YOU HAVE CAREFULLY READ AND 
UNDERSTAND THE INSTRUCTIONS AND WARNINGS IN THIS MANUAL. 

! WARNING ! 

NEVER 

exceed the stated maximum working pressure of the pump or of the lowest rated component in your 

system. 

NEVER 

modify any part of this equipment. 

NEVER

 use combustible gas with this equipment. 

NEVER

 attempt repairs while the system is under pressure.   

NEVER

 attempt to disassemble the equipment while the system is under pressure. 

ALWAYS 

tighten fluid connections before using this equipment 

ALWAYS 

read/follow the fluid manufacturer’s recommendations regarding fluid compatibility. 

ALWAYS

 read/follow the fluid manufacturer’s recommendations regarding the use of protective clothing 

and equipment. 

ALWAYS

 use an air line filter/moisture eliminator at the air inlet for the pump. 

ALWAYS

 use air line lubrication. 

REGULARLY 

check all equipment and repair/replace worn or damaged parts immediately. 

 

FAILURE TO HEED THESE WARNINGS INCLUDING OVERPRESSURIZING, 
ALTERING PARTS, USE OF INCOMPATIBLE FLUIDS, MISUSE, OR USE OF 
DAMAGED/WORN PARTS MAY RESULT IN EQUIPMENT DAMAGE, 
PROPERTY DAMAGE, FIRE, EXPLOSION AND/OR SERIOUS PERSONAL 
INJURY. 
 
SAFETY INSTRUCTIONS 

Extreme caution should be used when operating this equipment as it generates very high fluid pressure.  
Leaks from loose or ruptured components or material from dispensing valve can inject fluid through the skin 
causing serious bodily injury and possible need for amputation.  Always wear protection to prevent material 
splashing onto skin or into eyes.

  

IMPORTANT:

  GET EMERGENCY MEDICAL CARE IMMEDIATELY IF ANY FLUID APPEARS TO 

PENETRATE THE SKIN!  INFORM PHYSICIAN OF EXACTLY WHAT WAS INJECTED.  PLEASE 
DO NOT TREAT THIS INJURY AS A SIMPLE CUT. 

AIR OPERATED CHASSIS PUMP 

50:1 RATIO, OUTPUT – 80 CU. IN./MIN. 

MIN. AIR PRESSURE – 30 PSI 

MAX. AIR PRESSURE – 120 PSI 

       MAX. OUTPUT PRESSURE – 7500 PSI 

RECOMMENDED OPERATING PRESSURE 80-100 PSI 

GREASE TYPE: NLGI #2  

(maximum for effective performance)

 

OWNERS MANUAL

 

Содержание ATD5217

Страница 1: ...moisture eliminator at the air inlet for the pump ALWAYS use air line lubrication REGULARLY check all equipment and repair replace worn or damaged parts immediately FAILURE TO HEED THESE WARNINGS INCL...

Страница 2: ...TLY FOLLOW THE PRESSURE RELIEF PROCEDURE PRESSURE RELIEF PROCEDURE ALWAYS FOLLOW THIS PROCEDURE to reduce the risk of serious bodily injury including splashing into the eyes After shutting off the pum...

Страница 3: ...need Teflon tape to ensure a leak free connection Place air motor 91407 on pump head ATD5217 1 Place washer 33034 and cover nut 11478 on pump stud and thread air motor cover securely in place Ensure...

Страница 4: ...example if there is 100 psi of air pressure indicated on the regulator 100 psi of air entering then there is 5000 psi of grease pressure in the lubricant line Note Plastic Liner If the grease gun has...

Страница 5: ...the pump The Filter should be a moisture evaporator with an automatic dump on it so water is eliminated and purged from the air before entering the pump If you do not have a Filter Regulator on the p...

Страница 6: ...es Hoses Pumps and Control Valves Common If yes we suggest the use of a foot valve strainer ATD5356 82103ME Note To prevent Blockage in the pump hose lubricant lines or control valve with contaminated...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: