OPERATING INSTRUCTIONS                                          

1000A DC/AC CLAMP METER 

 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer 

to the manual for further information. 

 

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous 

voltages may be present 

 

Double insulation 

 

SAFETY NOTES 

• 

Do not exceed the maximum allowable input range of any function 

• 

Do not apply voltage to meter when resistance function is selected. 

• 

Set the function switch OFF when the meter is not in use. 

WARNINGS

 

• 

Set function switch to the appropriate position before measuring. 

• 

When measuring volts do not switch to current/resistance modes.

 

• 

Do not measure current on a circuit whose voltage exceeds 240V. 

• 

When changing ranges using the selector switch always disconnect the test leads from 

the circuit under test.

 

• 

Do not exceed the maximum rated input limits.

 

CAUTIONS

 

Improper use of this meter can cause damage, shock, injury or death.  Read and 
understand this user manual before operating the meter. 
Always remove the test leads before replacing the battery. 
Inspect the condition of the test leads and the meter itself for any damage before operating 
the meter. Repair or replace any damage before use. 
Use great care when making measurements if the voltages are greater than 25VAC rms or 
35VDC. These voltages are considered a shock hazard. 
Remove the battery if the meter is to be stored for long periods. 
Always discharge capacitors and remove power from the device under test before 
performing Diode, Resistance or Continuity tests. 

• 

Voltage checks on electrical outlets can be difficult and misleading because of the 

uncertainty of connection to the recessed electrical contacts. Other means should be used 
to ensure that the terminals are not "live". 

• 

If the equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired. 
 
 
 
 
 

 
 
 

  Input Limits 

Function Maximum 

Input 

A AC 

1000A 

V DC, V AC 

600V DC/AC 

Resistance, Diode, Continuity, Capacitance, 

Frequency, Duty Cycle, Test 

250V DC/AC 

Temperature (

/

℉)

 

60V DC/24V AC 

 

Meter Description 

1. Current 

clamp 

2. Clamp 

trigger 

3.  Data Hold and Backlight button 
4. Mode 

select 

button 

5. Hz/% 

button 

6. LCD 

display 

7.  COM input jack 
8.  Rotary Function swith 
9. ZERO 

button 

10. Range select button 
11. V 

Ω℃

/

 jack 

12. Battery compartment on rear 

 

 
 
                                                                                                                        12 
 
                              
 

1. 

AC  DC 

     AC (alternating current)  

and DC (direct currrent) 

2.                    Minus sign 
3. 

8.8.8.8

 

  4000 count (0 to 3999)  

measurement reading 

4. 

AUTO 

       AutoRange mode 

5.                     Diode test mode  

6.  

 

 

•)))

          Audible Continuity 

7. 

HOLD 

       Data Hold mode 

 

9.

,

,

 

µ

,m,V,A,K,M,

Ω

,

 Units of measure list

 

 
 
 
 
 
 
 

u

n

7

8

5

6

3

4

A

AC

m V
k M

DC

¡ ã

¡ ã

F

 C

Hz%

9

2

1

A

4 00 A

4 0A

Model 5597