OPERATING INSTRUCTIONS
1000A DC/AC CLAMP METER
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user must refer
to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use, hazardous
voltages may be present
Double insulation
SAFETY NOTES
•
Do not exceed the maximum allowable input range of any function
•
Do not apply voltage to meter when resistance function is selected.
•
Set the function switch OFF when the meter is not in use.
WARNINGS
•
Set function switch to the appropriate position before measuring.
•
When measuring volts do not switch to current/resistance modes.
•
Do not measure current on a circuit whose voltage exceeds 240V.
•
When changing ranges using the selector switch always disconnect the test leads from
the circuit under test.
•
Do not exceed the maximum rated input limits.
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and
understand this user manual before operating the meter.
Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for any damage before operating
the meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Remove the battery if the meter is to be stored for long periods.
Always discharge capacitors and remove power from the device under test before
performing Diode, Resistance or Continuity tests.
•
Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical contacts. Other means should be used
to ensure that the terminals are not "live".
•
If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Input Limits
Function Maximum
Input
A AC
1000A
V DC, V AC
600V DC/AC
Resistance, Diode, Continuity, Capacitance,
Frequency, Duty Cycle, Test
250V DC/AC
Temperature (
℃
/
℉)
60V DC/24V AC
Meter Description
1. Current
clamp
2. Clamp
trigger
3. Data Hold and Backlight button
4. Mode
select
button
5. Hz/%
button
6. LCD
display
7. COM input jack
8. Rotary Function swith
9. ZERO
button
10. Range select button
11. V
Ω℃
/
℉
jack
12. Battery compartment on rear
12
1.
AC DC
AC (alternating current)
and DC (direct currrent)
2. Minus sign
3.
8.8.8.8
4000 count (0 to 3999)
measurement reading
4.
AUTO
AutoRange mode
5. Diode test mode
6.
•)))
Audible Continuity
7.
HOLD
Data Hold mode
9.
℃
,
℉
,
µ
,m,V,A,K,M,
Ω
,
Units of measure list
u
n
7
8
5
6
3
4
A
AC
m V
k M
DC
¡ ã
¡ ã
F
C
Hz%
9
2
1
A
4 00 A
4 0A
Model 5597