ATC HeatStat Underfloor Heating Thermostat
Installation And Operation Manual
HS500
Power
220-240V AC 50/60Hz
Temperature Range (Display)
0° to 40°
Temperature Range (Adjustment)
5° to 35°
Temperature Display accuracy
0.5°C
Sensor type
Internal 10kΩNTC
External 12kΩNTC @25°C
Program type
4 on/off per day (5+2)
Switching capacity (Relay)
16A Resistive. 1A Inductive
Working environment temperature
0° to 90°
Installation type
Wall Mounted
Connection Diagram
Specifications:
1. Read all instructions prior to installing this thermostat, failure to follow the instruc-
tions could damage the product or cause a hazardous condition.
2. Check the loading of the product you intend to connect to this thermostat to ensure
that the device is capable of switching the intended load. Do not connect the load if
it is rated higher than 16A.
3. After product installation is complete, follow the instructions given below to ensure
that the thermostat functions correctly.
4. This product must be installed by a qualified electrician.
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
Always disconnect power before installation, Risk of Electric Shock
or Equipment Damage.
CAUTION
Thank you for purchasing the ATC HeatStat wall
mounted heating controller, your thermostat
is equipped with five touch sensitive buttons
across the bottom of the thermostat for easy
control and a large easy to read screen that is
optimised for viewing from above.
The HS500 is designed for both underfloor
heating control with the supplied floor sensor
and normal room control using the built in
highly accurate room sensor.