CHAPTER 4. STATION WIRING
Carbon block, or equivalent protection is required at both building entrances.
Also sneak current protection is required. Protection can be provided by a
4-type protector or a 3-type protector plus a separate sneak current
protector. The 4-type protector is equipped with a heat coil for sneak current
protection. The 4-type protector is the preferred device because it
eliminates the need to evaluate the interbuilding cable runs and its
vulnerability to power cross faults. When the 3-type protector is used, a
separate sneak current protector is required. The multi-pair protector units
and the off-premises cabling must be locally engineered. Connectorized
multi-pair protector units (female 25-pair connector out) are recommended.
The protector units can be ordered from the Premises Distribution Systems
Equipment and Supplies Catalog.
Table 4-A shows the recommended protectors.
Table 4-A. Recommended Protectors
PROTECTORS
Primary
Sneak Current
Primary *
(w/heat coil)
Protectors *
3B1A
4B1C
79A Fuse
(carbon)
(carbon)
3B1E-W
4B1E-W
SCP-1
(wide gap
(wide gap
gas tube)
gas tube)
3C1S
4C1S
(solid state)
(solid state)
* A sneak current protector is always required
when a 3-type primary protector is used.
Requirement:
If protectors other than those listed in Table 4-A
are to be used in domestic installations, they must
be UL listed/approved. Also any protectors to be
used in Canadian installations must be CSA
certified.
The maximum range for protection of out-of-building analog telephones (500-,
2500-, or 7100- types) connected to a TN742 or TN769 analog line circuit
pack through a primary protector is 6000 feet when using 24 awg wire and
3600 feet when using 26 awg wire.
4-40
Содержание System 75
Страница 1: ...AT T AT T System 75 and System 75 XE Wiring...
Страница 2: ...AT T AT T System 75 and System 75 XE Wiring 555 200 111 Issue 2 August 1989...
Страница 16: ...System Wiring Figure 1 2 System Uniform Wiring Plan 1 7...
Страница 17: ...CHAPTER 1 INTRODUCTION Figure 1 3 Sample Uniform Wiring Installation 1 8...
Страница 29: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 1 Block Diagram of System 75 or 75 XE Installation 2 2...
Страница 35: ...CHAPTER 2 HARDWARE 66 110 Type Figure 2 4 110A Type 100 Pair Terminal Block 2 8...
Страница 36: ...110 Type Hardware Description Figure 2 5 110A Type 300 Pair Terminal Block 2 9...
Страница 98: ...Typical System Equipment Room Floor Plans 3 15...
Страница 143: ...CHAPTER 3 EQUIPMENT ROOM DESIGN 3 60...
Страница 144: ...Equipment Room Hardware And Cabling Installation 3 61...
Страница 162: ...Equipment Room Hardware And Cabling Installation 3 79...
Страница 163: ...Equipment Room Hardware And Cabling Installation 3 80...
Страница 197: ...Tables Table 4 A Recommended Protectors 4 42 v...
Страница 203: ...CHAPTER 4 STATION WIRING Figure 4 4 3 Pair to 4 Pair Wiring Labeling From Equipment Room to Information Outlet 4 6...
Страница 205: ...CHAPTER 4 STATION WIRING Figure 4 5 4 Pair Station Wiring Labeling From Equipment Room to Information Outlet 4 8...
Страница 212: ...Adjunct Powering 4 15...
Страница 214: ...Adjunct Powering 4 17...
Страница 216: ...Patch Cord Jumper Installation And Administration 4 19...
Страница 241: ...CHAPTER 4 STATION WIRING 4 44...
Страница 244: ...Miscellaneous Wiring Installation 4 47...
Страница 246: ...Miscellaneous Wiring Installation 4 49...
Страница 252: ...Miscellaneous Wiring Installation 4 55...
Страница 254: ...Miscellaneous Wiring Installation 4 57...
Страница 277: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION Figure 5 1 Connections for Loudspeaker Paging and Music on Hold 5 4...
Страница 314: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 41...
Страница 324: ...CHAPTER 5 AUXILIARY EQUIPMENT INSTALLATION 5 51...