Basic Telephone and Modem Interface 2 (BTMI-2).
The BTMI-2 is a replacement for the BTMI. It
connects telephones and data communications devices
such as autodialers, answering machines, cordless
telephones, facsimile machines, and modems to the
MERLIN II system. A timer may be connected to a
BTMI-2 for automatic answering based on time of day.
Unlike the BTMI, the BTMI-2 does not support
Conference, Drop, or line selection features. It can be
used with MERLIN II systems with Feature Module 1,
Feature Module 2, and Release 3.
●
Basic Telephones.
Basic Touch-Tone telephones,
connected to the MERLIN system with the Off-
Premises Telephone Interface (OPTI) and to outside
telephone lines, provide service to people at a remote
location. On-premises Basic Touch-Tone telephones
can be connected to the system with a Basic Telephone
and Modem Interface 2 or a Basic Telephone Module.
●
Frequency Generator.
If your basic carrier or
expansion carrier has a Basic Telephone (012)
Module, you must connect a Frequency Generator to
the Power Supply Module, located in the first slot of
each carrier containing Basic Telephone Modules.
The Frequency Generator converts 117-volt, 60-Hz
input power to 105-vol~ 30-Hz ringing voltage for
basic telephones connected to the Basic Telephone
Module.
●
General Purpose Adapter
(GPA). Permits
connection of accessories such a modem with PCs or
data terminals, cordless telephones, and autodialers to
a MERLIN II system voice terminal. To use this
accessory, you must program Auto Answer AU. The
GPA is for use with all analog voice terminals except
5-button and 10-button HFAI.
System Hardware 1-33
Содержание administration and
Страница 1: ...AT T 518 600 016 MERLIN II COMMUNICATIONS SYSTEM Installation Administration and Maintenance Manual ...
Страница 40: ...FIGURE 1 9 System architecture Theory of Operation 1 37 ...
Страница 175: ...Top cover Front cover FIGURE 2 27 Control unit covers Testing the System 2 107 ...
Страница 177: ...Top cover E m p t y m o d u l e FIGURE 2 28 Installing the control unit top cover Testing the System 2 109 ...
Страница 179: ...Front cover E m p t y module FIGURE 2 29 Installing the control unit front cover Testing the System 2 111 ...
Страница 211: ...FIGURE 3 I A MERLIN II System Display Console The Administrator Attendant Console 3 3 ...
Страница 213: ... FIGURE 3 2 A BIS 34D Console The Administrator Attendant Console 3 5 ...
Страница 217: ...1 1 FIGURE 3 3 Administration Menu for MERLIN II System Release 3 The Administrator Attendant Console 3 9 ...
Страница 218: ...t FIGURE 3 4 Administration Menu for MERIJN II System with Feature Module 2 3 10 The Administrator Attendant Console ...
Страница 331: ...General Tests 4 55 Reaming the Control Unit 4 55 Testing Outside Lines 4 56 ...
Страница 389: ...Section 5 Ordering Information Ordering Information 5 1 Product Listing 5 1 Ordering Information 5 1 ...