Follow the appropriate procedure below to renumber the
system. Be sure to update all of the planning forms that
are affected by the replacement or addition of a module.
With a Display Console
1
2
3
4
Enter administration mode by sliding the T/P switch to
P.
Press Conference twice.
The administration menu appears.
From the administration menu, press
[System], [More],
[Renumber]
.
Y
OU
see the message, “System is restarting. ..” When the
renumbering is complete, the administration menu appears on the
display.
Press Conference to return to the administration menu
or leave administration mode by sliding the T/P switch
to the center position.
With a BIS-34D Console
1
Enter administration mode by sliding the T/P switch to
P.
2
3
4
5
Press Conference twice.
Lights flash next to Adm
Tel, Adm Pool, Message,
and
Speaker.
Press Message.
Dial #299.
Lights next t
O
Adm Tel, Adm Pool Message, and Speaker begin
to flash. You hear two beeps and then see the message, ‘System is
Re-starting..."
If only the light next to Message flashes, one or
more calls are in progress and the procedure is not executed until
the light becomes steady.
Continue administration or leave administration mode
by sliding the T/P switch to the center position.
3-64 Administering a Changed System
Содержание administration and
Страница 1: ...AT T 518 600 016 MERLIN II COMMUNICATIONS SYSTEM Installation Administration and Maintenance Manual ...
Страница 40: ...FIGURE 1 9 System architecture Theory of Operation 1 37 ...
Страница 175: ...Top cover Front cover FIGURE 2 27 Control unit covers Testing the System 2 107 ...
Страница 177: ...Top cover E m p t y m o d u l e FIGURE 2 28 Installing the control unit top cover Testing the System 2 109 ...
Страница 179: ...Front cover E m p t y module FIGURE 2 29 Installing the control unit front cover Testing the System 2 111 ...
Страница 211: ...FIGURE 3 I A MERLIN II System Display Console The Administrator Attendant Console 3 3 ...
Страница 213: ... FIGURE 3 2 A BIS 34D Console The Administrator Attendant Console 3 5 ...
Страница 217: ...1 1 FIGURE 3 3 Administration Menu for MERLIN II System Release 3 The Administrator Attendant Console 3 9 ...
Страница 218: ...t FIGURE 3 4 Administration Menu for MERIJN II System with Feature Module 2 3 10 The Administrator Attendant Console ...
Страница 331: ...General Tests 4 55 Reaming the Control Unit 4 55 Testing Outside Lines 4 56 ...
Страница 389: ...Section 5 Ordering Information Ordering Information 5 1 Product Listing 5 1 Ordering Information 5 1 ...