Testing the IVP4 Switch Settings
If you know the board configuration, set the switches on each board correctly
and then perform this test to verify the correctness of the switch settings.
1
2
3
4
5
Set the switches for each board according to its cocfiguration and board
number. See Figures 3 and 4.
Install the board(s) and close the case.
Install the application software.
The AUDIX Voice Power application software has a “System Monitor”
function available. Open the System Monitor window and examine the
Service Status column. If the Service Status is blank, or if the System
Monitor window shows no fields at all, the board is either defective, or it
should have another configuration.
Check the configuration and switch settings and test again. If the board is
still not recognized, contact the next tier of AT&T Services support.
999-500-355-A — Documentation Update — November 1990 13