![AT&T 4 ESS Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/atandt/4-ess/4-ess_manual_2994836087.webp)
[2] Are multiple
clock chains
out-of-service
[5] Does Network
Clock Sync Unit
restore
No
No
Yes
Yes
At TTY, enter
Wait for copy soft
a = chain with
updating or OOS
from Step 2
[6] At TTY, enter
RST:SCLK O,NCSU O
!
RMV:NCLK O,CHAIN
a!
NCSU O
to hard BLM on SCLK O,
out-of-service
[3] Is Network
Clock Sync Unit
out-of-service
No
Yes
Yes
No
[1] See CAUTION 1.
Is any clock chain
oscillator needing
CLEAR PHASE ERROR — 39B OSCILLATORS
[4] See NOTE 1.
NOTE 1
should be in the up
STROBE
switches on
all 39B oscillators
or
ENABLE
position
CAUTION 1
This procedure
calls for UCL
restores of out-
of-service chains.
Contact next level
of technical
assistance
support for
TAP
234-151-013
134
DEC 1995
PAGE 1 of 19