SHORT MANUAL

ATAG MadQ cascade-/mixed circuit control
unit

Operation and symbols

General functions

Using  the  rotary  pushbutton,  selected  setvalues  and  para-
meters can be selected, changed and, by subsequently pres-
sing the button, stored.

Turn to the right (+): increasing settings
Turn to the left   (–): decreasing settings

Press once: Accept the selected value, store

Press long: Entry into the programming level (level

selection)

3 sec

Standard display

Weekday,  date,  time  heat
generator temperature

The  line  mark  identifies  the
active operating mode.

6633..55

1166::3322    

FFRR  2266.. MMAARR..;;0044

°C

ÀÀ

6633..55

1166::3322    

FFRR  2266.. MMAARR..;;0044

°C

Sunshade:
Summer shutdown active
(heating switched off, domestic
hot water according to program)

Ice crystal:
Frost protection for plant
active

Á

Á

6633..55

1166::3322    

FFRR  2266.. MMAARR..;;0044

°C

m

3

3 h

hs

s    mm   u

u

3

3 h

hs

s    mm   u

u

3

3 h

hs

s    mm   u

u

Special display symbols

5500--44

EERRRROORR

DDHHWW

Alarm message (e.g. domestic hot

water)

appears alternately with the stan-
dard display - notify
heating specialist!

3

3 h

hs

s    mm   u

u

For detailed information see manual Part 

Temperature set-

tings.

Heating curves 

(heating characteristics)

The heating curves adapt the heating performance, depen-
ding  on  the  respective  outside  temperature,  to  the  state  of
the building.

The following settings should be selected as a base value:

The coldest outside temperature that can be expected forms
the basis of the calculation of the heat demand. The heating
specialist can inform you of this.

Correcting the heating curve

For detailed information see manual Part 

Heating curve.

-

663300

DDAAYY

DDHHWW

°C

m

Setting range: 10°C to 

DHW

-Max-Temp.

Setting domestic hot water temperature

Note: 

During separate operation (heating- and domestic hot water
programs  individually  operable),  first  select  the  associated 
heating circuit and accept it by pressing the rotary pushbutton
before setting the day or night temperature.

Setting range:  5.0 to 30 °C

-

116600

RROOOOMM  NNIIGGHHTT

°C

m

Setting night temperature

For detailed information see manual Part 

Temperature set-

tings.

Heatingsystem

-12°C

-15°C

-18°C

Floor

1.10

1.00

0.90

Radiator

1.70

1.55

1.45

Convector

2.20

2.00

1.85

Temperature

change

Accept change

Temperature

change

coldest outside temperature (regional)

Heating

circuit

select

11..5500

HHCC

HHEEAATT..  CCUURRVVEE

Accept heating circuit 

11..5500

HHCC

HHEEAATT..  CCUURRVVEE

Room temperature too warm: reduce
Room temperature too cold:   increase

Heating curve

change

Accept change

Quit (return to standard display)

If necessary, access the next circuit and correct the slope of the
heating characteristics.

Important! 

Only make corrections after 1-2 days and then
only in small steps. Almost completely open the
thermostatic valves of the radiators, if present!

Accept change

HC

=

Unmixed circuit  

MC-1

=

Mixed circuit 1

MC-2=Mixed circuit 2

Art

.no

8A52

13

0

0

 /

 0

6.0

4

Subject 

to 

changes

Operating instruments of the control unit

2

3

4

5

6

7

1

8

9

10

1 – Rotary pushbutton
2 – Set day temperature
3 – Set night temperature
4 – Setting domestic hot water temperature
5 – Program selection button
6 – Key for heating curve adjustment
7 – Information button
8 – Key for emission measurement and manual operation 

(only heating specialist)

9 – Display
10 – Compartment for short manual

Setting range:  5.0 to 30 °C

-

221100

RROOOOMM  DDAAYY

°C

m

Setting day temperature

Accept change

For detailed information see manual Part 

Temperature set-

tings.

Temperature

change

FR.

12:42

26.MAR;;04

57.5