background image

2-lines display

Scientific Calculator

with

fractional and statistical

functions

Please read before using.

O

w

n

e

r'

M

a

n

u

a

l

Safety Precautions

Be sure to read the following safety precautions before using 
this calculator. Keep this manual handy for later reference.

Batteries

• After removing the batteries from the calculator, put them in 

a safe place where there is no danger of them getting into 
the hands of small children and accidently swallowed.

•  Keep  batteries  out  of  the  reach  of  children.  If  accidentally 

swallowed, consult with a physician immediately.

•  Never  charge  batteries,  try  to  take  batteries  apart,  or  allow 

batteries  to  become  shorted.  Never  expose  batteries  to 
direct heat or dispose of them by incineration.

•  Misuse  of  batteries  can  cause  them  to  leak  acid  that  can 

cause damage to nearby items and creates the possibility of 
fire and personal injury.

• Always make sure that a battery's positive (+) and negative 

(–)  sides  are  facing  correctly  when  you  load  it  into  the 
calculator.

• Remove the batteries if you do not plan to use the calculator 

for a long time.

• Use only the type of batteries specified for this calculator in 

this manual.

•  Dim  figures  on  the  display  of  the  calculator  indicate  that 

battery power is low. Continued use of the calculator when 
the battery is low can result in improper operation. Replace 
the battery as soon as possible when display figures become 
dim.

Disposing of the Calculator

•  Never  dispose  of  the  calculator  by  burning  it.  Doing  so  can 

cause  certain  components  to  suddenly  burst,  creating  the 
danger of fire and personal injury.

• The displays and illustrations (such as key markings) shown 

in this Owner's Manual are for illustrative purposes only, and 
may differ somewhat from the actual items they represent.

• The  contents  of  this  manual  are  subject  to  change  without 

notice.

– 1 –

Handling Precautions

• Be sure to press the "ON" key before using the calculator for 

the first time.

•  Even  if  the  calculator  is  operating  normally,  replace  the 

battery  at  least  once  every  three  years.  Dead  battery  can 
leak,  causing  damage  to  and  malfunction  of  the  calculator. 
Never leave the dead battery in the calculator.

•  The  battery  that  comes  with  this  unit  discharges  slightly 

during shipment and storage. Because ofthis, it may require 
replacement sooner than the normal expected battery life.

• Low battery power can cause memory contents to  become 

corrupted or lost completely. Always keep written records of 
all important data.

•  Avoid  use  and  storage  in  areas  subjected  to  temperature 

extremes.  Very  low  temperatures  can  cause  slow  display 
response,total  failure  of  the  display,  and  shortening  of 
battery  life.Also  avoid  leaving  the  calculator  in  direct 
sunlight,  neara  window,  near  a  heater  or  anywhere  else  it 
might become exposed to very high temperatures. Heat can 
cause  discoloration  or  deformation  of  the  calculator's  case, 
anddamage to internal circuitry.

• Avoid use and storage in areas subjected to large amounts of 

humidity  and  dust. Take  care  never  to  leave  the  calculator 
where  it  might  besplashed  by  water  or  exposed  to  large 
amounts  of  humidity  or  dust.  Such  elements  can  damage 
internal circuitry.

•  Never  drop  the  calculator  or  otherwise  subject  it  to  strong 

impact.

•  Never  twist  or  bend  the  calculator.  Avoid  carrying  the 

calculator  in  the  pocket  of  your  trou-sers  or  other 
tight-fitting clothing where it might be subjected to twisting 
or bending.

• Never try to take the calculator apart.
• Never press the keys of the calculator with a ball-point pen or 

other pointed object.

•  Use  a  soft,  dry  cloth  to  clean  the  exterior  of  the  unit.  If  the 

calculator  becomes  very  dirty,  wipe  it  off  with  acloth 
moistened  in  a  weak  solution  of  water  and  a  mildneutral 
household  detergent. Wring  out  all  excess  moisture  before 
wiping  the  calculator.  Never  use  thinner,  benzine  or  other 
volatile agents to clean the calculator. Doing so can remove 
printed markings and damage the case.

– 2 –

Two-lines Display

You can simultaneously check the calculation formula and its 
answer.  The  first  line  displays  the  calculation  formula.  The 
second line displays the answer.

Keys Layout

– 3 –

Before Starting Calculations

Modes

Before  starting  a  calculation,  you  must  first  enter  the  correct 
mode as indicated in the table below.

• Pressing the 

[MODE]

 key more than once displays additional 

setup screens. Setup screens are described in the sections of 
this  manual  where  they  are  actually  used  to  change  the 
calculator setup.

Note:
•  To  return  the  calculation  mode  and  setup  to  the  initial 

defaults shown below, press 

[SHIFT] [CLR] [2] [=]

.

  Calculation Mode: 

COMP

  Angle Unit: 

Deg

  Exponential Display Format:  Norm 1
  Fraction Display Format: 

a b/c

  Decimal Point Character: 

Dot

• Mode indicators appear in the upper part of the display.
•  Be  sure  to  check  the  current  calculation  mode  (SD,  REG, 

COMP)  and  angle  unit  setting  (Deg,  Rad,  Gra)  before 
beginning a calculation.

Input Capacity

•  The  memory  area  used  for  calculation  input  can  hold  79 

"steps". One step is taken up each time you press a number 
key  or  arithmetic  operator  key  (

).  A 

[SHIFT]

  or 

[ALPHA]

 key operation does not take up a step, so  inputting 

[SHIFT] [nPr]

, for example, takes up only one step.

•  You  can  input  up  to  79  steps  for  a  single  calculation. 

Whenever  you  input  the  73rd  step  of  any  calculation,  the 
cursor  changes  from  "_"  to  "

g

"  to  let  you  know  memory  is 

running  low.  If  you  need  to  input  more  than  79  steps,  you 
should divide your calculation into two or more parts.

– 4 –

  To perform this 

Perform this key 

To enter

 type of calculation: 

operation: 

this mode:

Basic arithimetic

calculations

Standard deviation

Regression calculations

[MODE][1]

[MODE][2]

[MODE][3]

COMP

SD

REG

• Pressing the 

[Ans]

  key recalls the last result obtained, which 

you  can  use  in  a  subsequent  calculation.  See  "Answer 
Memory" for more information about using the 

[Ans]

 key.

Making Corrections During Input

•  Use 

[

3

]

  and 

[

4

]

  to  move  the  cursor  to  the  location  you 

want.

• Press 

[DEL]

 to delete the number or function at the current 

cursor position.

•  Press 

[SHIFT]  [INS]

  to  change  to  an  insert  cursor  "      ". 

Inputting something while the insert cursor is on the display 
inserts the input at the insert cursor position.

•  Pressing 

[SHIFT]  [INS]

,  or 

[=]

  returns  to  the  normal  cursor 

from the insert cursor.

Replay Function

•  Every  time  you  perform  a  calculation,  the  Replay  Function 

stores  the  calculation  formula  and  its  result  in  replay 
memory.  Pressing  the 

[

5

]

  key  displays  the  formula  and 

result  of  the  calculation  you  last  performed.  Pressing 

[

5

again  back  steps  sequentially  (new  to  old)  through  past 
calculations.

•  Pressing  the 

[

3

]

  or 

[

4

]

  key  while  a  replay  memory 

calculation is on the display changes to the editing screen.

•  Pressing  the 

[

3

]

  or 

[

4

]

  key  immediately  after  you  finish  a 

calculation displays the editing screen for that calculation.

•  Pressing 

[AC]

  does  not  clear  Replay  memory,  so  you  can 

recall the last calculation even after you press 

[AC]

.

•  Replay  memory  capacity  is  128  bytes  for  storage  of  both 

expressions and results.

• Replay memory is cleared by any of the following actions:-

*When you press the 

[ON]

 key.

*When you initialize modes and settings by pressing 

[SHIFT] 

[CLR] [2] [=]

.

*When you change from one calculation mode to another.
*When you turn off the calculator.

Error Locator

•  Pressing 

[

4

]

  or 

[

3

]

  after  an  error  occurs  displays  the 

calculation with the cursor positioned at the location where 
the error occured.

– 5 –

Multi-statements

A multi-statement is an expression that is made up of two or 
more smaller expressions, which are joined using a colon 

[:]

.

Example:

  2

3 and then multiply the result by 4.

2 [

] 3 [ALPHA] [:] [Ans] [

] 4 [=]

[=]

Exponential Display Formats

This  calculator  can  display  up  to  10  digits.  Larger  values  are 
automatically  displayed  using  exponential  notation.  In  the 
case  of  decimal  values,  you  can  select  between  two  formats 
that determine at what point exponential notation is used.
• To change the exponential display format, press the 

[MODE]

 

key  a  number  of  times  until  you  reach  the  exponential 
display format setup screen shown below.

• Press 

[3]

.  On the format selection screen that appears, press 

[1]

 to select "Norm 1" or 

[2]

  for "Norm 2".

• Norm1

With Norm 1, exponential notation is automatically used for 
integer values with more than 10 digits and decimal values 
with more than two decimal places.

• Norm 2

With Norm 2, exponential notation is automatically used for 
integer values with more than 10 digits and decimal values 
with more than nine decimal places.

•  All  of  the  examples  in  this  manual  show  calculation  results 

using the Norm1 format.

– 6 –

Ansx4

20.

Fix Sci Norm

1    2   3

Decimal Point and Separator Symbols

You  can  use  the  display  setup  (Disp)  screen  to  specify  the 
symbols you want for the decimal point and 3-digit separator.
• To  change  the  decimal  point  and  separator  symbol  setting, 

press the 

[MODE]

 key a number of times until you reach the 

setup screen shown below.

• Display the selection screen. 

[1] [

4

]

•  Press  the  number  key  (

[1]

  or 

[2]

)  that  corresponds  to  the 

setting you want to use.

[1]

 (dot): 

Period decimal point, comma separator

[2]

 (comma): Comma decimal point, period separator

Stacks

This  calculator  uses  memory  areas,  called  "stacks",  to 
temporarily  store  values  (numeric  stack)  and  commands 
(command  stack)  according  to  their  precedence  during 
calculations.  The  numeric  stack  has  10  levels  and  the 
command  stack  has  24  levels.  A  stack  error  (Stack  ERROR) 
occurs  whenever  you  try  to  perform  a  calculation  that  is  so 
complex that the capacity of a stack is exceeded.
•  Calculations  are  performed  in  sequence  according  to 

"Calculation  Priority  Sequence".  Commands  and  values  are 
deleted from the stack as the calculation is performed.

Overflow and Errors

If  the  operational  range  of  the  unit  is  exceeded,  or  incorrect 
inputs are made, an error message will appear on the display 
and  subsequent  operation  will  be  impossible.   This  is  carried 
out by the error check function.  The following operations will 
result in errors :-

1. The  answer,  whether  intermediate  or  final,  or  any  value  in 

memory exceeds the value of 

±

9.999999999 

 10

99

.

2.  An  attempt  is  made  to  perform  function  calculations  that 

exceed the input range.

3.  Improper  operation  during  statistical  calculations,  e.g., 

attempting to obtain x or x

n without data input.

4. The  capacity  of  the  numeric  value  stack  or  the  command 

stack is exceeded.

5.  Input errors are made,  e.g.  5  

 

  3 = .

– 7 –

Disp

1

case (1) to case (3) 

Math ERROR

case (4) 

 

Stack ERROR

case (5) 

 

Syntax ERROR

The  calculator  is  locked  up  while  an  error  message  is  on  the 
display.  Press 

[AC]

  to  clear  the  error,  or  press 

[

3

]

  or 

[

4

]

  to 

display  the  calculation  and  correct  the  problem.  See  "Error 
Locator" for details.

*Internal digits: 12
For  a  single  calculation,  calculation  errors  is 

±

1  at  the  10th 

digit. (In the case of exponential display, calculation error is 

±

at the last significant digit.) Errors are cumulative in the case of 
consecutive  calculations,  which  can  also  cause  them  to 
become  large.  (This  is  also  true  of  internal  consecutive 
calculations that are performed in the case of 

ˆ

(x

y

x

 , x!, 

3

 , 

nPr, nCr etc.)
In  the  vicinity  of  a  function's  singular  point  and  point  of 
inflection, errors are cumulative and may become large.

Calculation Priority Sequence

Calculations  are  performed  in  the  following  order  of 
precedence :-
1. Coordinate transformation: Pol(x, y),Rec(r, 

)

2. Type A functions :-

With  these  functions,  the  value  is  entered  and  then  the 
function key is pressed: x

3

, x

2

, x

–1

, x!, º''',

x, x

1

, x

2

, y, 

angle unit conversions.

3. Powers and roots,  

ˆ

(x

y

),  

x

4. Fractions,  a

b

/

c

5.  Abbreviated  multiplication  format  in  front  of 

π

,  memory 

name or variable name, such as 2

π

, 5A, 

π

A, etc.

6. Type B functions :-

With  these  functions,  the  function  key  is  pressed  and  then 
the value is entered.

3

, log, ln, e

x

, 10

x

, sin, cos, tan, sin

–1

, cos

–1

, tan

–1

, sinh, cosh, 

tanh, sinh

–1

, cosh

–1

, tanh

–1

, (–).

7.  Abbreviated  multiplication  format  in  front  of  Type  B 

functions: 2

3, A log2, etc.

8. Permutation, combination,  nPr,  nCr
9. 

10. 

– 8 –

•  Operations  of  the  same  precedence  are  performed  from 

right to left :-  e

x

ln

120 

 e

x

{ln(

120)}.

• Other operations are performed from left to right.
• Operations enclosed in parentheses are performed first.

Initializing the Calculator

•  Perform  the  following  key  operation  when  you  want  to 

initialize  the  calculation  mode  and  setup,  and  clear  replay 
memory and variables.

[SHIFT] [CLR] [3] [=]

Basic Calculations

Arithmetic Calculations

 

Use the 

[MODE]

 key to enter the COMP Mode when you want 

to perform basic calculations (

[MODE] [1]

).

•  Negative  values  inside  of  calculations  must  be  enclosed 

within parentheses.

sin –1.23 

 

[sin] [(] [(–)] 1.23 [)]

•  It  is  not  necessary  to  enclose  a  negative  exponent  within 

parentheses.

sin 2.34 

 10

–5

 

 

[sin] 2.34 [EXP] [(–)] 5

– 9 –

 

 

Display

Example 

Operation 

(Lower)

23 + 4.5 –53 =–25.5
56

(–12)

(–2.5)=268.8

12369

7532

74103= 

6.903680613

10

12

(4.5

10

75

)

(–2.3

10

–79

) =  –1.035

10

–3

(2+3)

10

2

=500

(1

10

5

)

7=

14285.71429
(1

10

5

)

7

14285=

0.7142857 
please note that internal calculation is calculated
in 12 digits for a mantissa and the result is
displayed and rounded off to 10 digits. 

23 [

] 4.5 [

] 53 [=]

56[

][(–)]12[

][(–)]2.5[=]

12369[

] 7532 [

]

74103[=]
4.5[EXP]75 [

] [(–)]2.3

[EXP] [(–)]79 [=]
[( ] 2 [

] 3[ )][

] 1

[EXP]2 [=]
1[EXP]5 [

] 7 [=]

1[EXP]5[

]7 [

]

14285 [=]

–25.5
268.8

            6.903680613

12

            

            –1.035

–03

            

500.

      14285.71429

0.71428571

Percentage Calculations

– 10 –

 

 

Display

Example 

Operation 

(Lower)

 3 + 5 

 

6 = 33

 7 

 8 

 4 

 5 = 36

 1 

 2 

 3 

 4 

 5 

 6

= 6.6
100 

 (2

3) 

 4 = 80

 3 

 ( 4 

 5 ) = 29

( 7 

 2 ) 

 ( 8 

 5 ) = 65

10 

 { 2 

 7 

 ( 3 

 6 )}

= –55

3 [

] 5 [

] 6 [=]

7 [

] 8 [

] 4 [

] 5 [=]

1 [

] 2 [

] 3 [

] 4 [

]

5 [

] 6 [=]

100 [

][( ] 2 [

] 3[ )]

[

] 4 [=]

2 [

] 3 [

] [(] 4 [

] 5 [=]

Closed parentheses
occurring immediately
before operation of the
[=] key may be omitted.
[( ] 7 [

] 2 [ )][( ] 8 [

] 5 [=]

A multiplication sign [

]

occurring immediately
before an open parantheses
can be omitted.
10 [

][( ] 2 [

] 7 [( ] 3 [

]

6 [=]

33.
36.

6.6

80.
29.

65.

–55.

 

 

Display

Example 

Operation 

(Lower)

Percentage

26% of $15.00

Premium

15% increase from
$36.20

Discount

4% discount from
$47.50

Ratio

75 is what % of 250?

Rate of change

141 is an increase of
what % from 120?

Rate of change

240 is a decrease of
what % from 300?

15 [

]26 [SHIFT] [%]

36.2[

]15 [SHIFT] [%] [

]

47.5[

]4 [SHIFT] [%] [

]

75[

]250 [SHIFT] [%]

141[

]120 [SHIFT] [%]

 
240[

]300 [SHIFT] [%]

3.9

            
            

41.63

 

45.6

30.

 

  

17.5

–20.

Fractions

• You  can  use  the  display  setup  (Disp)  screen  to  specify  the 

display  format  when  a  fraction  calculation  result  is  greater  
than one.

• To change the fraction display format, press the 

[MODE]

 key 

a  number  of  times  until  you  reach  the  setup  screen  shown 
below:-

• Display the selection screen.  

[1]

•  Press  the  number  key  (

[1]

  or 

[2]

)  that  corresponds  to  the 

setting you want to use.  

[1]

 (a b/c): mixed fraction.  

[2]

 (d/c): 

improper fraction.

• An error occurs if you try to input a mixed fraction while the 

d/c display format is selected.

– 11 –

Disp

1

 

 

Display

Example 

Operation 

(Lower)

2

/

5

3

1

/

4

 = 3

13

/

20

3

456

/

78

 = 8

11

/

13

1

/

2578

1

/

4572

= 6.066202547

10

–4

1

/

2

0.5 = 0.25

1

/

3

(–

4

/

5

)–

5

/

= –1

1

/

10

1

/

2

1

/

3

1

/

4

1

/

5

13

/

60

(

1

/

2

)/

1

/

6

1

/(

1

/

3

1

/

4

)

 

= 1

5

/

7

2[a

b

/

c

]5[

]3[a

b

/

c

]1

[a

b

/

c

]4[=]

(conversion to decimal)[a

b

/

c

]

Fractions can be converted
to decimals, and then
converted back to fractions.
3[a

b

/

c

]456[a

b

/

c

]78[=]

[SHIFT][

d

/

c

]

1[a

b

/

c

]2578[

]1[a

b

/

c

]

4572[=]
When the total number
of characters, including
integer, numerator,
denominator and
delimiter mark exceeds
10, the input fraction is
automatically displayed
in decimal format.
1[a

b

/

c

]2[

].5[=]

1[a

b

/

c

]3[

][(–)]4[a

b

/

c

]5

[

]5[a

b

/

c

]6[=]

1[a

b

/

c

]2[

]1[a

b

/

c

]3[

]

1[a

b

/

c

]4[

]1[a

b

/

c

]5[=]

[(]1[a

b

/

c

]2[)][a

b

/

c

]3[=]

1[a

b

/

c

][(]1[a

b

/

c

]3[

]

1[a

b

/

c

]4[)][=]

3

13

20.

3.65

8

11

13.

115

13.

6.066202547

–04

0.25

–1

1

10.

13

60.

1

6.

1

5

7.

0

1

2

3

EXP

Ans

DEL

AC

=

+

4

5

6

7

8

9

+

÷

STO

X

Y M– M

RCL

(

)

,

;

M+

º

,,,

hyp

sin

cos

tan

tan

–1

DT CL

cos

–1

ln

log

a

b

/c

d/c

3

x

10

x

e

x

e

ENG

x

2

x

3

x

–1

nCr

Pol(

Rec(

nPr

x

!

(–)

:

SHIFT

REPLAY

ON

ALPHA

MODE CLR

Rnd

S-SUM

S-VAR

Ran#

%

DRG

π

INS

OFF

F

E

sin

–1

D

C

B

A

2+3

5.

Disp

Отзывы: