14.7 Humidity too high
✓
At first startup, wait at least 24 hours for the cabinet to stabilize.
✓
The cabinet is in a regeneration cycle, it is normal the humidity will rise during this procedure.
✓
Unplug the cabinet, wait 5 seconds and power up the cabinet. Wait at least 6 hours to check
if the humidity decreases.
✓
Check the cabinet for any leakage, check the doors and any open connections to the
environment.
✓
Check if the cabinet is fully loaded with wet components, the cabinet needs time to dry these
components.
✓
Insufficient air flow
⇒
convections vents covered.
✓
Fan failure
⇒
replace drying unit.
14.8 Temperature too low
✓
Heating module switched off
⇒
switch on heating module.
✓
Heating module power supply interrupted
⇒
check mains connection.
✓
Plug connection to drying unit disconnected
⇒
check plug connection.
✓
Heater or ventilator failure
⇒
replace defect components.