Asycube 50 & 80
Operating Manual
©
Copyright Asyril S.A.
000.100.501
Version: A1
Operating Manual - Asycube 50 & 80
37/45
Recover IP address using default IP address
The following procedure explains how to reboot the Asycube on the default IP address,
subnet mask and tcp port number to be able to modify IP address, subnet mask and tcp port
number when they are unknown and cannot be found. Following this procedure, you are able
to connect on the Asycube with default parameters and then modify unknown parameters.
Step 1
Remove the hopper
Unscrew the 4 screws
(A)
and remove
the cover
(B)
Use a torx key size 10
Step 2
Place selector 1 in "on"
position
(C)
Step 3
Disconnect and reconnect the power cable (or switch off and switch on the power on the
Asycube).
The Asycube will take the default parameters by the new startup :
IP: 192.168.127.254
SubnetMask: 255.255.255.0
TCP Port: 4001
(A)
(B)
1
2
3
4
(C)