ASUS Zero-Channel RAID Board
27
MegaRAID BIOS Config Utility(40-Ld) Ver5.40 Apr 21, 2003 Standard:Adapter-01
SPACE-Array,ENTER-Configure,F2-Drive Information,F3-Logical Drives,F4-HotSpare
Ch-1 ID-0 DISK 17521MB FUJITSU MAN3184MC 0109
Management
Configure
Initialize
Objects
Format
Rebuild
Check Consistency
New Configuration - ARRAY SELECTION MENU
ID
Channel-1
ONLIN A01-01
ONLIN A01-02
ONLIN A01-03
ONLIN A01-04
0
1
6
5
4
3
2
ID
Channel-2
0
1
6
5
4
3
2
3. Use the arrow keys to select a
specific physical drive, then press
the <Space bar> to associate the
selected drive with the current array.
The indicator for the selected drive
changes from
READY
to
ONLIN
Axx-xx
.
>> where
Axx-xx
means:
A[array number]-[drive number]
For example,
ONLIN A01-01
means
disk drive 1 in array 1.
If possible, use identical drives (with the same type and capacity) in one array.
If you use drives of different capacities in one array, all the drives are treated
as if they have the capacity of the
smallest
drive in the array.
4. Follow steps 4 to 12 in section “5.2 Easy Configuration.” For instructions on
creating multiple arrays, refer to the
MegaRAID Configuration Software
Guide
in the support CD.