3.7.4.2
Manage Digital I/O
Set Digital Output State
Use the following command to set digital output state to ON or OFF
$ setdo
CHANNEL
STATE
CHANNEL
0, 1, 2, or 3
STATE
set to 1 for ON or 0 for OFF
Example:
Get Digital Input Status
Use the following command to check the status of digital input:
$ getdi
CHANNEL
CHANNEL
0, 1, 2, or 3
The system will return a value of 1 for ON and 0 for OFF.